Procedure:
Place the lid on a firm non-slip level surface.
The O-ring can be extracted using an O-ring extractor tool (make sure the tool as no sharp edges).
Alternatively use the flats of the thumbs to gently stretch the O-ring on two faces (Fig. 4) thus making
a small loop protruding a few mm. The loop can then be grasped between finger and thumb, to pull the
O-ring over the lip.
• Clean the O-ring recess (the square groove where the O-ring sits) with a cotton bud.
• Inspect the O-ring all the way round its surface for damage such as cuts tears or contamination.
This should be done visually and also by feeling the surface texture between finger and thumb.
IF THE O-RING IS DAMAGED OR SUSPECTED OF BEING DAMAGED, DISCARD IT
IMMEDIATELY. A spare O-ring is supplied with your housing, or a replacement O-ring can be
obtained from 10 BAR. If the O-ring is contaminated or suspected of being contaminated, clean it with
a cotton cloth that is free of all chemicals or contamination. After cleaning inspect the O-ring again.
Once the O-ring has been inspected and verified fit for use, apply a
SMALL
amount of silicone grease
to the O-ring. The silicone grease must be evenly distributed round the O-ring
Replace the O-ring into the groove; run a finger round the O-ring, to make sure it is snugly seated in
the groove.
(Fig.6) Stretch the O-ring
4.5 Mounting the flashlight in the housing:
Set the flashlight in normal position. Slide the flashlight all the way into the hot shoe of the
housing until it is stop (Fig. 7), Turn the lock ring follow the direction "LOCK". Take care not to
excessively tighten the screw (Fig. 8). Note: If you find that control levers do not locate properly with
the buttons, please check again that the flashlight is properly seated to the limit of the guide rail.