8.18. Remove the Plasma panel sec-
tion from the Cabinet assy
1. Remove the Cabinet mount metals fastening screws (×10
).
2. Remove the cabinet assy and the plasma panel fastening
, ×8
screws (×3
3. For leaving the plasma panel from the front frame, pull the
bottom of the cabinet assy forward, lift, and remove.
).

8.19. Remove the Contact metals

1. Remove the Cabinet assy. (See section 8.18.)
2. Remove the screws (×4
3. Remove the Contact metal top.
4. Remove the screws (×4
5. Remove the Contact metal bottom.
6. Remove the screws (×4
7. Remove the Contact metal side (L, R).

8.20. Remove the K-Board

1. Remove the Contact metal bottom. (See section 8.19.)
2. Remove the screw (×1
3. Remove the claw (×1
4. Disconnect the connector (K1) and Remove the K-Board
from LED Panel.