Download Print this page

Prime PME 50 Installation Manual

Advertisement

Quick Links

INSTALLATION MANUAL
Models : PME 50, PME70, PME90, PME110, PME130
PME50L, PME70L, PME90L, PME110L, PME130L
SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURES WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT. THIS
PRODUCT MUST BE INSTALLED BY A QUALIFIED TECHNICIAN
Please read these instructions before attempting to install, operate or service the ventilation fan, Failure to comply with instruction could be
result in personal injury and / or property damage. Please save these instructions for further reference.
INSTALLER LEAVE THIS MANUAL WITH THE HOMEOWNER
IMPORTANT SAFELY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.
Use this fan in the manner intended by the manufacturer. If you have questions, contact the manufacturer or distributors / dealer.
2.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards,
including fire rated construction.
3.
Before servicing or cleaning this fan, switch power off at service panel, and lock the service disconnecting means to prevent power
from being switching on accidentally.
4.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning- equipment to
prevent back-drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
ASHRAE), and the local code authorities.
5.
When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utility.
6.
Ducted fans must always be vented to the outdoors.
7.
Solid state controls may cause harmonic distortion which can cause motor humming noise. To reduce the risk of fire or electric shock,
do not use this unit with any solid- state control device.
8.
Never place a switch where it can be reached from a tub or shower.
9.
Not t No.o be installed in a ceiling thermally insulated to a value greater than R40.
10. These units are cULus listed for use over a tub and shower when connected to a GFCI (Ground Fault Circuit Interrupter) – protected
branch circuit.
11. This unit must be grounded
CAUTION:
Installation work and electrical wiring must be done by qualified persons in accordance with all applicable codes and standard, including
fire-rated construction.
1.
Fan is for general ventilating use only. Do not use to exhaust hazardous or explosive material
and vapors.
2.
Not for use in a cooking area ( Fig. 1)
3.
This fan is designed fore installation in ceiling up to a 7/12 pitch. Duct connector must point up.
DO NOT MOUNT THIS FAN IN A WALL.
FOR VENTILATING FAN
DO NOT INSTALL ABOVE OR
INSIDE THIS AREA
FLOOR
COOKING
EQUIPMENT
FIGURE 1

Advertisement

loading

Summary of Contents for Prime PME 50

  • Page 1 INSTALLATION MANUAL FOR VENTILATING FAN Models : PME 50, PME70, PME90, PME110, PME130 PME50L, PME70L, PME90L, PME110L, PME130L SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURES WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT. THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED TECHNICIAN Please read these instructions before attempting to install, operate or service the ventilation fan, Failure to comply with instruction could be result in personal injury and / or property damage.
  • Page 2 Rough Opening: 17.8cm (7”) l * 17.8cm (7”) w Housing Size: 17cm (6 11/16”) l * 17cm (6 11/16”) w * 18.5cm(7 9/32”) h PME 50, PME 50L, PME 70, PME 70L, PME 90, Tapping Screw PME 90L, PME 110, PME 110L, PME 130, PME 130L Fan Housing with sliding hanger bars installed Rough Opening: 26.5cm (10 1/2”) l * 26.5cm (10 1/2”) w...
  • Page 3: Specifications

    SWITCH BOX BLACK (BROWN) BLACK (BROWN) IMPORTANT: The power to your PRIME Air ventilation fan must disconnect before installation WHITE (BLUE) WHITE (BLUE) AC POWER begins. Be certain all wiring complies with local codes and that the fan unit is properly ground.
  • Page 4 File This Warranty with Your Important Papers Prime warrants to the original consumer purchaser of its products that such products will be free from defects in materials and / or workmanship for a period of three years from the date of original purchase. Consumer must provide proof of date of purchase.