3.1.3 INSPECTION (FAULT ANALYSIS PROGRAM) METHOD

Caution: Please use in the Real MS-DOS mode. (The program does not work in the MS-DOS prompt (DOS window) of the
Windows.)
• Discs to be used
CD-ROM
DVD-ROM (Single)
DVD-ROM (Dual)
DVD-RAM Recorded disc
CD-R Blank disc
CD-RW Blank disc
DVD-R Blank disc
DVD-RW Blank disc
DVD+R Blank disc
DVD+RW Blank disc
DVD+R DL Blank disc
• Inspection program disc
FA Program Disc: GGS1061
• Installation method
Copy the program file "R8a_fa.exe" .
• Execution method
1. Start the PC in the MS-DOS mode.
2. Move to the directory to which the program file has been copied.
Example: cd dvr108 [enter]
3. Execute the program.
r8a_fa /e /sv [enter]
Operation
To move the window
To select the measurement item
To execute the measurement
To execute all items continuously
To quit the program
• Start-up screen
R8
5
6
:GGV1054
:GGV1035
:GGV1036
:GGV1181
:GGV1126 (Mitsui) or GGV1216 (TAIYO-YUDEN)
:GGV1088 (Multi Speed) or GGV1089 (High Speed) or GGV1215 (Ultra Speed)
:GGV1139 (PIONEER or GGV1219 (TAIYO-YUDEN)
:GGV1170 (TDK) or GGV1218 (TDK)
:GGV1217 (Mitsubishi-Chemical) or Richo
:GGV1220 (Mitsubishi-Chemical) or Richo
:GGV1221 (Mitsubishi-Chemical) or Mitsubishi
(For "C:\dvr108")
Key Operation
Right or left cursor keys
Up or down cursor keys
Enter key
Space key
Esc key
for FA
(GGS1061)
r8a_fa.exe ver0.5
LDI C
6
7
Operation
To format
1. DVD-RW, 2. DVD+RW, 3. CD-RW
To select the drive unit
1. R7, 2. R6