2.3
DESCRIPTION OF PROTECTIVE DEVICES
2.3.1 Thermal protection
This machine is protected by a thermostat, which prevents
the machine from operating if the allowable temperatures are
exceeded. In this condition the display will show the error
code E1.

3 INSTALLATION

Only skilled personnel should install the machine. All con-
nections must be carried out according to current regula-
tions, and in full observance of safety laws (regulation CEI
26-10 - CENELEC HD 427).
1. Place the welding machine in a stable and safe position.
Air must circulate freely, both incoming and outgoing,
and the welding machine must be protected from entry
by liquids, dirt, metal filings, etc.
2. Make sure that the supply voltage matches the voltage
indicated on the specifications plate of the welding
machine. When mounting a plug, make sure it has an
adequate capacity, and that the yellow/green conductor
of the power supply cable is connected to the earth pin.
The capacity of the overload cutout switch or fuses
installed in series with the power supply must be equiv-
alent to the absorbed current I1 of the machine.
Any extension cords must be sized appropriately for the
absorbed current I1.
Q
O
B
A
P
S
T
R
U
3. Pacemaker wearers are prohibited from using the
machine or approach the cables.
4. Fully insert the earth cable plug into une socket (U or V)
and turn clockwise.
5. Fully insert the gun plug into one socket (U or V) and turn
clockwise.
6. Insert the 3-pin control connector into the socket pro-
vided; if the manual cycle "MAN" is selected, the spot-
welding cycle begins when the torch trigger is pressed.
7. Turn on the welding machine using the switch X on the
back of the machine.
8. To limit exposure to the magnetic field, keep the gun
cable on the side of the hand holding it, avoiding wrap-
ping the cable around.

4 DESCRIPTION OF THE EQUIPMENT

A- Key to select the operator "USER".
B- LED. Signals the activation or shutdown of the oper-
ator selection function.
C- Key. Activates the pulse heating function.
It is used to produce heat on thick sheet metal.
It delivers three consecutive pulses at a fixed inter-
val of 360 msec.
The buttons S and T adjust the power; display R
shows the setting.
Minimum = 20 Maximum = 90.
D
C
E
F
G
H
I
L
M
N
W
V
Fig. 1
Y
X
7