Download Print this page

Sharp ER-A520 Programming Manual page 21

Electronic
Hide thumbs Also See for ER-A520:

Advertisement

* 7 In case of CCD COMPULSORY for ALL SERVER:
Until DAILY ALL SERVER RESETTING is done, any other daily
reports that reports the CID can not be executed.
The key sequence for DAILY ALL SERVER RESETTING.
In case of CCD COMPULSORY for the INDIVIDUAL SERVER:
Until ALL SERVER RESETTING is done, any other reports that
reports the CID totals can not be executed.
The key sequence for the INDIVIDUAL server/cashier resetting is
unique and is outlined below.
<CCD ENTRY>
JOB#
@/FOR
Q'ty
Amount
@/FOR
Repeat
*
#
CONV1
Amount
CONV2
CONV3
SBTL
* : The Non-add [#] function key is used for CASH and CHECK
amount entry.
** : The total CASH and CHECK amount entered by [#] can be dis-
played by depressing the [SBTL].
* 8 The stacked report function enables different reports to be printed
successively with a single reporting operation.
The programming for the stacked reports can be accomplished in
the PGM2 mode.
Stacked reports can be printed by performing the following key
operation in the X1/Z1 and X2/Z2 modes.
Reading
x90
@/FOR
CA/AT
Resetting
If the job code of a report within the stacked report preset is pro-
grammed, it is ignored (that report is not printed).
Also, if stacked reports include any other reports for which a Z reports
can not be taken, the reports are ignored and are not printed.
A maximum of 15 different reports can be printed successively with
a single reporting operation.
Those 15 reports can include those reports that are identical in
code number. In this case, however, if any data changes due to the
printing of the previous report, the changed data is printed on the
following report.
For example:
Consecutive number: The counter is incremented by one.
Z report:
Data is reset to zero.
CA/AT
#
CONV1
VOID
CA/AT
CONV2
CONV3
ER-A520/ER-A530 REPORT MODES (OP X/Z, X1/Z1 and X2/Z2)
* 9 Reading display only.
The displayed amount can be cleared by deparessing the [CL] key.
KEY
(Display amount)
[Action]
Individual counters for the following Z reports are incremented when
those reports are printed.
1) General daily total report (Z1)
2) General periodic total report (Z2)
3) Hourly report (Z1)
4) Daily net total report (Z2)
5) PLU/UPC report (Z1/Z2)
6) Individual server and All server report (Z1/Z2)
[Additional function]
(1) Secret code entry
When printing reports in the X1/Z1 mode and X2/Z2 mode, if a
secret code has been preset, the code must be entered prior to per-
forming key operation to take reports.
The secret code can be entered following the procedure shown
below.
XXX
CA/AT
Secret code
(2) Overflow mark
If the amount or quantity in any totalizer other than the GT to be
printed on an X or Z reports exceeds a programmed limit, the indi-
cation mark (overflow mark) is printed for the totalizer concerned.
Q'TY:
Max. 7 (-9999999~+9999999)
AMOUNT: Max. 9 (-999999999~+999999999)
The overflow mark may be printed even if a totalizer does not reach
the maximum amount. This occurs, for example, when the amount
or quantity in the totalizer gets smaller than the maximum amount
due to the entry of a negative amount after the overflowing of the
totalizer. This means that when the totalizer overflows once, the
overflow mark (for example, "!!") is printed.
(3) MODE TITLE
Each report prints a MODE TITLE at a header of report.
The Report Titles are as follows.
OPX report
#051 * OPX *
OPZ report
#051 * OPZ *
X1 report
#151 * X 1 *
Z1 report
#151 * Z 1 *
X2 report
#251 * X 2 *
Z2 report
#251 * Z 2 *
(4) Report cancel function
All report printing can be stopped.
Printing can be cancelled by turning the mode switch to MGR posi-
tion while the data is printing. (In this case, the contents of memory
are not cleared.)
<Print sample of Report cancel>
:
:
*
*
*
*
123456789012345678901234
4 – 3
CL
(Display initialize)
* 10
* 11
CA/AT
*
1 the report cancel symbol

Advertisement

loading

This manual is also suitable for:

Er-a530