NVT NV-EC1701 Complete Installation Manual

NVT NV-EC1701 Complete Installation Manual

Eoc ethernet over coax transceiver

Advertisement

Model NV-EC1701
EoC Ethernet over Coax Transceiver
with PoE, PoE+, or High Power PoE
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with a dry cloth.
7) Install in accordance with the manufacturer's instructions.
8) Do not install near any heat sources such as radiators, heat regis-
ters, stoves or other apparatus (including DVRs) that produce heat.
9) Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong.
The wider blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10) Protect the power cord from being walked on or pinched particu-
larly at plugs, convenience receptacles, and the point where they exit
from the apparatus.
11) Only use attachments/accessories specified by the manufacturer.
12) Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way, such as
a power supply cord or plug is damaged, liquid has been spilled, or
objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been
dropped. This installation should be made by a qualified service per-
son and should conform to all local codes.
13) BNC Connection: the installation shall be in accordance with the
applicable provisions of the National Electrical Code ANSI/NFPA 70,
Article 800.90 and Canadial Electrical Code Part 1, Section 60-504.
14) RJ45 PoE connection: to be connected only to networks or circuits
that are not routed to outside plant or building.
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER OR
BACK. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT EXPOSE THIS
APPARATUS TO RAIN OR MOISTURE.
This installation should be made by a qualified service person and
should conform to all local codes.
operating ambient temperature exceeds 185° F (85° C). The ventila-
tion should not be impeded by covering the unit with items, such as
newspapers, table-cloths, curtains, etc. No naked flame sources, such
as lighted candles should be placed on the apparatus.
use more than two power supplies within a network system.
splashing and no objects filled with liquids, such as vases, shall be
placed on the apparatus.
mains) assemblies for location installed.
remain readily operable.
duit as high-voltage wiring.
This product is intended to be supplied by a certified power source
marked "Class 2" or "LPS" and rated 48-56 VDC, minimum 840mA,
which may or may not be provided with the product.
Power supplies, when provided, are external inline, with an IEC380-
C14 power inlet and 6 ft (1.8 m) line-cord. Input Voltage is 100 ~240
VAC 50-60 Hz. A molded P1J 5.5 mm barrel connector provides a
Class 2 (SELV) 48-56 VDC regulated output. Line cord UL approved
type SPT-2, SVT, or SJT, 18/3 AWG Min. 300VAC, 60° C Max. 15ft
(4.5m) long. One end with IEC380-C13 appliance coupler and the
other end with NEMA 1015P or equivalent for country.
Page 1 of 14
Complete Installation Guide
WARNING - Do not install the unit in an environment where the
WARNING - Do not interconnect multiple outputs. Never
WARNING - The apparatus shall not be exposed to dripping or
WARNING - Use only a Certified power cord and plug (coupler /
WARNING - Power cord is regarded as main disconnect.
WARNING - The appliance coupler (power cord/mains) shall
WARNING - For safety, never put NVT signals in the same con-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NV-EC1701 and is the answer not in the manual?

Questions and answers

Summary of Contents for NVT NV-EC1701

  • Page 1 12) Refer all servicing to qualified service personnel. Servicing is WARNING - For safety, never put NVT signals in the same con- required when the apparatus has been damaged in any way, such as duit as high-voltage wiring.
  • Page 2: Product Overview

    PoE or PoE+ or High Power PoE cameras*. These transceivers are extremely simple to use, with no IP or MAC addressing required. Status LEDs indicate power and link connectivity/activity for RJ45 and BNC ports. They are backed by NVT’s award winning customer support and limited lifetime warranty.
  • Page 3: Configuration Instructions

    NV-EC1701 transceivers must be configured to communicate exclusively with other transceivers within their Network Group. This group typically consists of one NV-EC1701 located at the control room (usually connected to an ethernet switch or router), and up to four remote NV-EC1701 transceivers (usually connected to IP cameras).
  • Page 4: Installation Instructions

    Connect an RJ45 patch-cord between the RJ45 jack on the the replacement of an analog camera with an IP camera, while NV-EC1701 and either: 1) an IP camera video input on a Hybrid reusing the installed coax cable. Since most IP cameras support DVR, or 2) an Ethernet switch allocated for video.
  • Page 5 Firewall 6 Watt RJ45 IP Camera Port ≤328ft Model NV-EC1701 Ethernet over Coax Transceiver www.nvt.com ● (+1) 650.462.8100 ● (+44) (0) 208 977 6614 ≤328ft IP Camera (≤100m) (≤100m) ≤ 1,850 ft (560 m) with a 48V power supply Power Supply ≤...
  • Page 6: Network Architecture

    Traffic Management Considerations When sharing the resources of a LAN, the nature of the traffic must The NV-EC1701 supports TCP/IP, UDP, HTTP, Multi-cast, and other stan- be well understood for it to operate efficiently. For most end-users, dard protocols. This allows for the transmission of other network traffic the business use of their LAN is constantly changing, critical for their besides streaming video.
  • Page 7 IP Distance Calculator at www.nvt.com Figure 4 - Alternate Power Supply Location The NV-EC1701 has a power inlet connector that receives 48 or 56 volts from an external Class 2 SELV desk-style power supply. Power is distributed to: 1) the transceiver’s internal electronics;...
  • Page 8 Model NV-EC1701 EoC Ethernet over Coax Transceiver with PoE, PoE+, or High Power PoE WIRE DISTANCE CHARTS The distance capability of wire is dependant on its ability to deliver DC power, and separately, to deliver high-frequency data signals. The graph below shows maximum power delivery when using a 48V power supply. If you are using a 56V power supply, your distances will be 2.6 times those shown in figure 4.
  • Page 9 Model NV-EC1701 EoC Ethernet over Coax Transceiver with PoE, PoE+, or High Power PoE WIRE DISTANCE CHARTS Wire type and Data Distance Capability There are a wide variety of wire qualities, from copper-plated steel at the low end (CATV wire) to high performance low-loss pure copper.
  • Page 10: Technical Specifications

    Model NV-EC1701 EoC Ethernet over Coax Transceiver with PoE, PoE+, or High Power PoE TECHNICAL SPECIFICATIONS R J 4 5 E T H E R N E T I N T E R F A C E M E C H A N I C A L / E N V I R O N M E N T A L...
  • Page 11: Model Numbers

    Model NV-EC1701 EoC Ethernet over Coax Transceiver with PoE, PoE+, or High Power PoE MODEL NUMBERS Product NV-EC1701: Single transceiver only, no power supply Accessories NV-PS48-60W: 48VDC power supply, 60 watts with IEC line cord NV-PS56-60W: 56VDC power supply, 60 watts...
  • Page 12 Model NV-EC1701 EoC Ethernet over Coax Transceiver with PoE, PoE+, or High Power PoE TRANSCEIVER KITS Model NV-EC1701 EoC Ethernet over Coax Transceiver Kits Product Kits Single EoC Transmission System NV-EC1701-KIT1: 2 NV-EC1701 Transceivers 1 NV-PS48-60W Power Supply with IEC line cord...
  • Page 13 Cat5 Cat5 IP Camera Model NV-EC1701 Ethernet over Coax Transceiver www.nvt.com ● (+1) 650.462.8100 ● (+44) (0) 208 977 6614 Firewall 2- wire Cable Power Supply Figure 6 - Multicast Network On rare occasions, a customer will experience a problem where...
  • Page 14: Troubleshooting

    For example, test the IP camera obligation on the part of NVT with respect to any of the products.In the directly at the ethernet switch without other equipment. Then add in the event that any of the products is damaged, altered, or modified without NVT transceivers, back-to-back.