START
Is AMBER
LED
status
light ON solid,
alternately
flashing
bright-dim-bright-dim
like a heartbeaL
or flashing
ON and
OFF?
YES
Is AMBER
LED
status
light ON solid?
NO
Is AMBER
LED
status
light alternately
flashing
brighbdim-bright-dim
like a
heartbeat?
NO
Determine
status
code.
The status
code
is a single
or two digit number
with the
first number
determined
by the number
of
short flashes
and the second
number
after the plus (+) sign is the number
of
long flashes?
1
Go to section
below
for the status
code
that
was flashed.
1
Troubleshooting
Guide - ICP Variable
Speed
p
I--_
Is door switch
closed i
YES
I
I-'_
I
Is there
115V
gOing tO switch?
YES
I
I
Replace
do°r
switch
-4
Is there
115Vat
L1 and L2?
_
YES
Is there
24V at SEC-1
and SEC-2?
NO
_
YES
._
Is the 24V fuse
open?
4l
YES
Replace
fuse then
disconnect
thermostat
leads
to isolate
short circuit.
Replace
transformer.
]
-4
I
Replace
furnace
control.
I
Check
to make
sure that the correct
model
plug PL4 is installed.
The wiring
schematic
shows
all valid model
plugs.
Is the correct
model
plug installed?
_
NO
Replace
model
plug PL4.
The control
is locked
out and will auto-
reset after 1 hour.
Lockout
could
be due
to any of the following:
-
Flame
sense
circuit
failure.
-
Gas valve
relay stuck
open.
-
Software
check
error.
Reset
power
to clear lockout.
Replace
control
if code
repeats.
The last status
code has cleared.
To
recall
a previous
status
code disconnect
the R thermostat
connection,
reset
power,
and put setup
switch
SWI-1
in
the ON position.
The AMBER
LED will
flash
the status
codes
in the order
of
occurrence.
Record
status
codes
until
heartbeat
flashes.
After
heartbeat
flashes
several
times the status
codes
will repeat.
Status
codes
are erased
after 72 hours
or can be manually
erased
by putting
setup
switch
SWI-1
in the ON
position
and jumpering
R, W/W1,
and
Y/Y2 simultaneously
until the heartbeat
flashes.
When
done
put setup
switch
SWl-1
in the OFF position.
Was
there
a previous
status
code
other
than
the heartbeat?
I
Does
the control
respond
to W/W1,
W2,
Y1, Y/Y2,
and G (24V)
thermostat
signals?
YES
Run system
through
a low-heat,
high-
heat,
or cooling
cycle to check
operation.
Status
codes
are erased
after 72 hours
or can be manually
erased
by putting
setup
switch
SWI-1
in the ON position
andjumpering
R, W/W1,
and Y/Y2
simultaneously
until the heartbeat
flashes.
Replace
furnace
control.
Close
the door switch.
I-_
Is circuit
breaker
closed?
YES
J
Check
for continuity
in wire from circuit
breaker
to furnace.
Close
circuit
breaker
and go back
to
START.
Check
room thermostat
or
interconnecting
cable.
T.o
t_
s 24V present
at W/W1,
W2, Y1, Y/Y2 or
G thermostat
terminals
on the furnace
control?
YES
Disconnect
all the thermostat
wires
from
the furnace
control.
_
oes the problem
reieat
when
using a
jumper
wire?
NO
The thermostat
is not compatible
with the
furnace
control
Either
install
a ballast
resistor,
connect
the Com24V
thermostat
terminal
to the thermostat,
or replace
the
thermostat
I
F
"11
i-
tj'l
0")
I
--I
e-
=r
o
£
._.
ID
e-
I
#
e_