Xceed X2300KS Instruction Manual

Xceed X2300KS Instruction Manual

Petrol generator

Advertisement

INSTRUCTION MANUAL
X2300KS / 254-2173
2300W
PETROL GENERATOR

Advertisement

Table of Contents
loading

Summary of Contents for Xceed X2300KS

  • Page 1 INSTRUCTION MANUAL X2300KS / 254-2173 2300W PETROL GENERATOR...
  • Page 2: Table Of Contents

    Risk of moving parts Risk from lifting special care to heed the Cautions and Warnings. Additional safety rules for generators Your Xceed power tool has many features that will make Unpacking Know your product your job faster and easier. Safety, performance, and...
  • Page 3: Introduction

    Wear eye protection. special care to heed the Cautions and Warnings. Fuel type: Unleaded Wear hearing protection. Your Xceed power tool has many features that will make Wear breathing protection. your job faster and easier. Safety, performance, and Oil type: 4 Stroke...
  • Page 4: Safety Instructions

    Safety instructions Personal safety • Stay alert, watch what you are doing and use WARNING. Read and understand all instructions. common sense when operating a power tool. Failure to follow all instructions listed below may result in Do not use a power tool while you are tired or under the electric shock, fire and/or serious injury.
  • Page 5 Power tool use and care • Do not force the power tool. Use the correct power tool for your application. The correct power tool will do the job better and safer at the rate for which it was designed. • Do not use the power tool if the switch does not turn it on and off.
  • Page 6: Risk Of Electrocution And Fire

    Risk of electrocution and fire Hazard What could happen How to prevent it Extension cord can come into contact Remove extension cord from the Improper storage of extension cord. with hot engine parts resulting in generator and store separately away damage.
  • Page 7: Risk Of Fire

    Risk of fire Hazard What could happen How to prevent it Fuel and fuel vapours can become ignited Turn engine off and allow it to cool before Attempting to fill the fuel by coming in contact with hot components adding fuel to the tank. Equip area of tank while the engine is such as the muffler, engine exhaust gases, operation with a fire extinguisher certified...
  • Page 8: Risk Of Injury And Property Damage When Transporting Generator

    Risk of injury and property damage when transporting generator Hazard What could happen How to prevent it Fuel or oil can leak or spill and The generator is equipped with a fuel drain valve, Fire, inhalation, damage could result in fire or breathing turn the valve to the off position before transporting to to vehicle surfaces hazard, serious injury or death...
  • Page 9: Risk Of Hot Surfaces

    Risk of hot surfaces Hazard What could happen How to prevent it Contact with hot surfaces, such as During operation, touch only the Contact with hot engine and engines exhaust components, could control surfaces of the generator. Keep generator components. result in serious burns.
  • Page 10: Additional Safety Rules For Generators

    Due to modern mass production techniques, it is unlikely spilling of fuel as this may also ignite with the hot motor. that your Xceed generator is faulty or that a part is missing. Never refuel whilst the engine running. If you find anything wrong, do not operate the tool until the •...
  • Page 11: Know Your Product

    Know your product 1. Fuel tank 2. Fuel tank cap 3. Fuel level gauge 4. AC circuit breaker 5. DC reset button 6. Ground (frame) terminal 7. Oil filler cap 8. AC sockets 9. DC battery charging socket 10. DC appliance socket 11.
  • Page 12: Automatic Voltage Regulator (Avr)

    Ensure you DO NOT fuel the generator in close proximity ie. kettles, toasters to any open flames, lit cigarettes, or hot objects. The Xceed 2300w generator is not recommended for use • The generator should also be located in an open area on sensitive electronic equipment including LCD / plasma with fresh air and NOT in a confined area.
  • Page 13: Checking The Engine Oil

    1. Check the Red positive wire is connected to the battery Checking the engine oil terminal and the insulating cover is fully pulled over the The motor of this generator is not filled with oil when unpacked. terminal. Prior to starting the motor ensure the crank case is filled with 2.
  • Page 14: Starting The Engine With Key Start (Electric Start Models)

    5. Once you hear the motor Starting the engine with key start operating, release the key Note. Before starting the motor, ensure you have filled the to allow the position to crank case to the correct level with oil and fuel has been move from ‘START’...
  • Page 15: Starting The Engine Manually

    Starting the engine manually Stopping the engine Note. Follow steps 1 to 3 of 1. Before stopping, ensure that no electrical apparatus is the ‘Starting the engine with connected to the generator. key start’ section. 2. Turn the key start ignition 1.
  • Page 16: Ac Circuit Breaker

    Be sure that all appliances are in good working order before WARNING. Prior to connecting any appliance to the connecting them to the generator. If an appliance begins to generator, check the rating label of the appliance. The operate abnormally, becomes sluggish, or stops suddenly, generator has a rated value and is shown on the generator turn “OFF”...
  • Page 17: To Use The Appliance Outlet

    The 12V – 14V outlets are suitable to charge most size lead To use the battery charging outlet acid type car batteries while the appliance outlet will run The generator is fitted with most 12V appliances fitted with the car cigarette type plug, a socket outlet specifically rated up to 5A.
  • Page 18: To Use The Usb Power Outlet

    After connection to the battery, RECHECK to ensure the To use the USB power outlet connections are as above. These range of generators are fitted with a 5 Volt USB 2. Start the generator and allow the generator to warm up. power outlet.
  • Page 19: To Use The Dc Appliance Outlet Or Usb Without The Generator Being Operated

    To use the DC appliance outlet or USB 12V appliance socket: 10 amp. without the generator being operated 5 V USB: 1 amp. Both sockets can be used at the one time. The 12 volt appliance outlet and or the USB outlet can be used if a 12V car battery is connected to the charging socket Note.
  • Page 20: Carbon Build Up

    5. When re connecting appliances, reduce the load to that If the generator is being used for solely charging a battery, which previously overloaded the generator. it is recommended to run the 240Vac at around 500W for the generators up to 2000W and 1000W for the generators Note.
  • Page 21: Periodic Maintenance

    Periodic maintenance Item Remarks Pre-operation Initial 1 Every 3 Every 6 Every 12 check (daily) months months months months or 20Hr or 50Hr or 100Hr or 300Hr Check condition, adjust gap and Spark plug • clean. Replace if necessary. Check oil level. •...
  • Page 22: Storage

    Storage Engine oil replacement If you are going to store your generator for more than 30 1. Place the generator on a level surface and warm up the days, use the following information as a guide to prepare the engine for several minutes. The stop the engine. generator for storage.
  • Page 23: Petrol Tank Filter

    2. Remove the air filter (Fig. V). Tap extension fuel filter 3. Wash the air filter in solvent A small fuel filter has been fitted to the inlet side of the fuel or kerosene and allow to dry. valve (20), inside the tank. This tap extension fuel filter (24) 4.
  • Page 24: Cleaning

    replaced. Do not operate the generator without this filter in Cleaning place. To replace the filter after cleaning, or with a new filter, 1. Keep your machine clean. The outside of the machine simply screw the filter into the inlet side of the tap. can be cleaned using a damp soft cloth with a mild 5.
  • Page 25: Troubleshooting

    Troubleshooting Trouble Possible cause Suggested remedy 1. Low on fuel or oil content 1a. Add Fuel ( ensure fuel is fresh) Engine will not start 1b. Fill oil in motor until oil runs out of filler hole 2. Generator not sitting on level ground. 2.
  • Page 26 Troubleshooting (continued) Trouble Possible cause Suggested remedy 1. Generator overloaded 1. Reduce load Generator overheating 2. Insufficient ventilation 2. Move to adequate supply of fresh air 1. DC circuit overloaded. 1a. Remove DC load and reset cut out No DC Output after 5 min 1b.

Table of Contents