Failure Codes - Blomberg TKF 8439 Service Handbook

Hide thumbs Also See for TKF 8439:
Table of Contents

Advertisement

Arçelik/Blomberg 2009 ARES MLCD 8 kg

Failure Codes :

Failure
code
0
1
2
3
4
5
6
ERROR_HEATER_HIGH_TEMPERATURE
7
ERROR_DOOR_HIGH_TEMPERATURE
8
9
10
ERROR_TEMPERATURE_DIFFERENCE
11
ERROR_HEATER_TEMPERATURE_RAPIDLY_INCREASED
12
13
14
15
16
17
Tumble Dryer Service Handbook
Description
ERROR_CONSTANT_VALUE
N/A
ERROR_TANK_FULL
ERROR_ROTARY
ERROR_HEATER_NTC
ERROR_DOOR_NTC
ERROR_CLEAN_FILTER
ERROR_BROKEN_STRAP
ERROR_DOOR_OPENED
ERROR_HIGH_VOLTAGE
ERROR_LOW_VOLTAGE
ERROR_MAX_TIME
ERROR_DRUM_IDLE
ERROR_Program_ROTARY
Explanation
The same valued is read
for 5 minutes
N/A
Water tank is full
Rotary is broken
Heater NTC is shot circuit
or open circuit.
Door NTC is shot circuit or
open circuit.
Heater tempareture is
over limit.
Door tempareture is over
limit.
Filter is full with fuzz
V-belt is broken
The temparature
difference between heater
NTC and Door NTC is 60
degrees
Heater temparature is
rapidly increased between
15 and 25 seconds.
The door is opened during
the cycle.
The voltage is over 265V .
The voltage is
under 165V .
If the humidity sensor
drying programs reaches
its maximum time limits.
Only beginning of sensor
drying programs.
If the Rotary is turned
during Run Mode.