BUS-TECH 40-01459-D0-001 Installation Manual

Pci escon adapter

Advertisement

Quick Links

EnterpriseExpress Adapter/ESCON
PCI ESCON A
dapter
INSTALLATION GUIDE
Installation Guide
Part Number 40-01459-D0-001
129 Middlesex Turnpike, Burlington Ma. 01803
(781) 272-8200 Fax (781) 272-0342
www.bustech.com

Advertisement

Table of Contents
loading

Summary of Contents for BUS-TECH 40-01459-D0-001

  • Page 1 EnterpriseExpress Adapter/ESCON PCI ESCON A dapter INSTALLATION GUIDE Installation Guide Part Number 40-01459-D0-001 129 Middlesex Turnpike, Burlington Ma. 01803 • (781) 272-8200 Fax (781) 272-0342 • www.bustech.com...
  • Page 2 COMPLIANCE WITH APPLICABLE REGULATIONS DEPENDS ON THE USE OF SHIELDED CABLES. IT IS THE USER WHO IS RESPONSIBLE FOR PROCURING THE APPROPRIATE CABLES. Bus-Tech PCI ESCON Installation Guide Sixth Edition (January 2001) Part Number 40-01459-D0-001 Copyright 2001 by BUS-TECH, INC. © 129 Middlesex Turnpike Burlington, MA 01803...
  • Page 3: Table Of Contents

    Table of Contents BOUT UBLICATION Who Should Use This Publication ...iii How to Use This Publication ...iii What is Included in This Publication ...iii What’s New in this Release?... iv 1. I HAPTER NTRODUCTION Server Software ... 1 Related Documentation ... 2 Minimum System Requirements...
  • Page 5: About This Publication

    About This Publication This User's Guide provides the information necessary to install and configure Bus- Tech's PCI ESCON Adapter (PBSA) to connect a Server to an IBM Mainframe. The following terms are used as synonyms for the PCI ESCON Adapter in this publication and in some software installation screens: Bus-Tech PCI to ESCON Adapter (PBSA) PBSA...
  • Page 6: What's New In This Release

    CHAPTER 6. TROUBLESHOOTING – This chapter takes the reader through some troubleshooting steps to be tried when the adapter is not working properly. What’s New in this Release? Plug and Play drivers for Microsoft Windows 2000 Server have been added to the installation kit.
  • Page 7: Chapter 1. Introduction

    Chapter 1. I NTRODUCTION The PCI ESCON Adapter from Bus-Tech, Inc. is a high performance adapter that enables PCI-based systems to communicate with mainframe systems through direct IBM channel attachment. The ESCON adapter acts as a control unit for Enterprise Systems Connections (ESCON);...
  • Page 8: Related Documentation

    Additionally, the PCI ESCON Adapter includes TCP/IP Direct Connect for the Windows 2000 and NT environments. Direct Connect provides a high-performance, point-to-point TCP/IP connections between the mainframe and the server’s TCP/IP stack and can be used with Bus-Tech’s MPC+ for Windows NT to provide High- Speed Data Access Services (HSAS) and MPC Point-to-Point (MPCPTP) connections.
  • Page 9: Minimum System Requirements

    Minimum System Requirements Hardware The minimum hardware requirements for using the PCI ESCON Adapter are: - Pentium 100Mhz - 64MB RAM for Windows NT Systems -128MB RAM for Windows 2000 Systems - 1 Available PCI BusMaster Slot - 2 MB Hard Disk Space (for Bus-Tech Drivers) Software Windows The supported releases of Microsoft software are:...
  • Page 11: Chapter 2. Hardware Installation

    Chapter 2. H ARDWARE Installing the Adapter CAUTION! The PCI ESCON Adapter is a PC adapter card and as such can be damaged by Electrostatic Discharge. Before removing the adapter from it’s protective static bag, please ensure that you are free of static charge. At minimum, you should ground yourself to the system you are using.
  • Page 12 4. Remove the adapter from its protective anti-static bag and insert the adapter into the chosen PCI bus slot. Make sure the adapter is fully inserted in the slot. Place a screw through the top of the mounting bracket and securely fasten to the system chassis.
  • Page 13: Chapter 3. Driver Installation

    Chapter 3. D RIVER The PCI ESCON Adapter offers drivers for Microsoft's Windows 2000 Server and Microsoft Windows NT Server. This chapter discusses installation of the drivers. Please refer to the section appropriate to your operating environment. Windows 2000 Note: Bus-Tech adapters include drivers for both Windows 2000 and Windows NT. These drivers are different and can only be installed in the appropriate environment.
  • Page 14 Figure 3-2. Search the Floppy The hardware wizard will search the Windows directory and then the floppy disk. When it finds the PBSA drivers it will prompt you for approval to install (Figure 3-3). Figure 3-3. Confirm PBSA Driver Install Windows 2000 will install the new drivers.
  • Page 15 Figure 3-4. New Found Hardware Wizard Completing Driver Installation 9...
  • Page 16: Windows Nt

    Windows NT The PBSA network driver is always required in order to allow Windows NT to communicate with the adapter. The driver must be installed once for each PCI ESCON Adapter installed in the system. The following step-by-step procedure will install the driver into your Windows NT Server.
  • Page 17 Figure 3-6. Network Screen 3. From the Select Network Adapter screen (Figure 3-7), click the Have Disk... button. Figure 3-7. Add Network Adapter Driver Installation 11...
  • Page 18 4. The Insert Disk screen is displayed (Figure 3-8). With the floppy inserted into the floppy drive point to the root directory by entering "A: " where A is your floppy drive and press OK. 5. The Select OEM Option dialog box will be displayed (Figure 3-9). Highlight\select the Bus-Tech PCI ESCON Adapter and click OK.
  • Page 19 Figure 3-10. ESCON Configuration 7. As shown in Figure 3-11, the adapter should now be listed in the Network Adapters box. Clicking Close will cause the system to configure the network and prompt you to restart the system. Figure 3-11. Network Settings Showing PBSA Driver Installation 13...
  • Page 21: Escon Configuration

    Chapter 4. ESCON C Figure 4-1. ESCON Attached Controllers Overview ESCON controllers, including the PCI ESCON Adapter (PBSA), can be connected to the mainframe in more than one fashion. As shown in Figure 4-1, Controller 1 is attached directly to one of the mainframe’s ESCON channels. Assuming the mainframe is running a single Logical Partition (LPAR), this is simplest option for connecting an ESCON controller to the mainframe.
  • Page 22 Finally, using both ESCON Directors and EMIF, it is possible for a single ESCON controller to communicate with multiple Logical Partitions (LPARs) running on multiple mainframes, using multiple ESCON channels. Because an ESCON controller may be attached to an ESCON director, which may be connected to multiple mainframes and Logical Partitions (LPARs), it is necessary to configure the ESCON controller in order to define how the unit will appear to each environment.
  • Page 23 Channel Link – The address of the ESCON director port that connects to the mainframe this device is to communicate with. The value range is from 01-FE hexadecimal. In Figure 4-2 the mainframe uses a channel link address '02' to communicate with Server 1.
  • Page 24: Configuration

    Configuration ESCON configuration may be defined and viewed from any of the upper level software including the data link service for Microsoft’s Host Integration Server or SNA Server, data link control for Communications Server, TCP/IP Passthrough, TCP/IP Direct Connect, or MPC+ for Windows. Clicking a Configure ESCON button will immediately display the ESCON devices configured for the adapter (see Figure 4-6) and allow you to add, modify, or remove devices in the list.
  • Page 25 In Windows NT the ESCON configuration may be accessed through the system Control Panel. From the main screen of Control Panel double click the Network Icon (See Figure 4-4). Figure 4-4. Windows NT Control Panel Select the Adapters tab (Figure 4-5). Figure 4-5.
  • Page 26 The Bus-Tech PCI ESCON Adapter should be included in the list. Selecting the Bus-Tech adapter and clicking Properties will bring up the ESCON Configuration Screen (Figure 4-6). Figure 4-6. Bus-Tech’s ESCON Configuration Screen To configure a new device click Add… Figure 4-7.
  • Page 27 device A0 and A1, enter 2. Optionally enter a Description to be associated with this device. Remember that for TCP/IP Passthrough and TCP/IP Direct Connect CTC connections you must define two consecutive devices. Additionally for TCP/IP Passthrough the first device must be even numbered (00, 02, 20, 40, A0, etc.) Press Add to add the device(s) to the ESCON configuration file.
  • Page 29: Tcp/Ip Direct Connect 23

    Chapter 5. TCP/IP D TCP/IP Direct Connect software included with the PCI ESCON Adapter provides high-performance, point-to-point TCP/IP communications between a Windows server (Windows 2000 or Windows NT 4.0) and the mainframe. TCP/IP Direct Connect operates over Channel-to-Channel (CTC) or Multi-Path Channel Plus (MPC+) links. TCP/IP Direct Connect is not required and does not need to be installed for TCP/IP Passthrough for Windows NT, Communications Server, Microsoft’s Host Integration Server or Microsoft’s SNA Server.
  • Page 30: Windows 2000

    TCP/IP Direct Connect supports three link types across the ESCON channel: Channel-to-Channel (CTC), High-Speed Access Services (HSAS) for UDP, or Multi- Path Channel Point-to-Point (MPCPTP). HSAS and MPCPTP require installation of MPC+ for Windows (MPC+). CTC links use two ESCON devices (one for read, one for write) to communicate with mainframe TCP/IP stacks such as OS/390 TCP/IP, MVS TCP/IP and VM TCP/IP.
  • Page 31 2. Click OK when Setup displays it’s Welcome dialog (Figure 5-4). Figure 5-4. TCP/IP Direct Connect Install Confirmation 3. The TCP/IP Direct Connect Properties dialog will display (Figure 5-5). Figure 5-5. TCP/IP Direct Connect Properties You must define the Link type and Link properties in order to complete the install.
  • Page 32 defined by the install you have just completed. Right click the connection and select Properties (Figure 5-7). Figure 5-7. New Local Connection 6. Uncheck Client for Microsoft Networks, File and Printer Sharing for Microsoft Networks, and DLC Protocol since these services are not supported on the mainframe (Figure 5-8).
  • Page 33 7. Enter an IP address and Subnet mask to be associated with this link on the server. This is the address a mainframe-based application will use to establish contact with the Windows 2000 server (Figure 5-9). The address must be in the same IP subnet as the address assigned to this link on the mainframe.
  • Page 34: Deleting A Link

    Deleting a Link To remove a previously installed TCP/IP Direct Connect link from Windows 2000, you must uninstall the TCP/IP Direct Connect Adapter. This is accomplished using the Device Manager in the Windows 2000 Computer Management utility (Figure 5-10). 28 PCI ESCON Adapter Installation Guide Figure 5-10.
  • Page 35: Windows Nt

    Windows NT The following step-by-step procedure will install the TCP/IP Direct Connect and configure it for use without MPC+. Installation and configuration of TCP/IP Direct Connect using MPC+ is discussed in the “MPC+ for Windows NT Installation Guide”. The PBSA driver must be installed before TCP/IP Direct Connect (see Page 10). Step 1.
  • Page 36 Figure 5-12. Adapter List with ESCON Adapter 3. Click the Add button to add a new adapter. The Select Network Adapter dialog box will display a list of adapters included with Windows NT (Figure 5-13.). Figure 5-13. Select Network Adapter 4.
  • Page 37 Figure 5-14.Insert Disk 5. Insert the TCP/IP Direct Connect diskette into your floppy. Click OK. 6. The Select OEM Option dialog (Figure 5-15) will display TCP/IP Direct Connect. Click OK to install the driver. Figure 5-15. Select OEM Option 7. The TCP/IP Direct Connect Adapter Properties screen for Channel-to-Channel (CTC) link type (Figure 5-16) will display.
  • Page 38 Figure 5-16. Adapter Properties You must define the Link type and Link properties in order to complete the install. Please refer to the Link Configuration section later in this chapter. 8. After defining the fields click Close to save your values and return to the Network Adapters screen (Figure 5-17).
  • Page 39 9. Click on Bindings. Show bindings for all adapters (Figure 5-18). Check that only the TCP/IP Protocol is bound to the TCP/IP Direct Connect Adapter. Disable any other service or protocol bound to TCP/IP Direct Connect. Figure 5-18. Adapter Bindings 10.
  • Page 40 11. Use your mouse to select TCP/IP Direct Connect from the list of Adapters bound to TCP/IP (Figure 5-20). Figure 5-20. Select TCP/IP Direct Connect 12. Enter an IP Address and Subnet Mask; defining the address that the mainframe will use to communicate with the server (Figure 5-21). Note that the mainframe IP address and this address must be in the same subnet.
  • Page 41 Figure 5-21. Assigning an IP Address to the ESCON Adapter 13. Click OK. Windows NT will complete the binding process and prompt you to reboot the server. You must reboot for network changes to take affect. Installation of TCP/IP Direct Connect is complete. TCP/IP Direct Connect 35...
  • Page 42: Link Configuration

    Link Configuration Figure 5-22 shows the properties that must be configured for CTC Links. Complete these fields as follows: Mainframe IP Address – The IP address of the mainframe this connection is to communicate with. This must match the HOME IP address assigned in the TCP/IP Profile.
  • Page 43 MTU – Maximum Transmission Unit must match what is defined on the mainframe for this connection or packet loss will occur. The recommended MTU for CTC connections is 32000. To configure MPC+ links, either HSAS or MPCPTP, please refer to the MPC+ for Windows Installation Guide.
  • Page 44: Mainframe Configuration

    Mainframe Configuration This section discusses configuration of the mainframe for use with TCP/IP Direct Connect over a Channel-to-Channel (CTC) link. Mainframe configuration for Communications Server, SNA Server, TCP/IP Passthrough for Windows NT, and MPC+ for Windows is discussed in the user’s guide that accompanied each individual product.
  • Page 45: Tcp/Ip Profile

    TCP/IP Profile TCP/IP Direct Connect links require the IBM TCP/IP protocol stack running on your System/390. Your TCP/IP Profile will need to be modified to support the new link. The following is an example of the entries required to define a connection: ;...
  • Page 46 Figure 5-23. Multiple TCP/IP Direct Connect ESCON Configuration 40 PCI ESCON Adapter Installation Guide IOCDS – LPAR 0 *** CHPID STATEMENTS *** CHPID PATH=((22)),TYPE=CNC,SWITCH=01,SHARED *** CNTLUNIT STATEMENTS *** CNTLUNIT CUNUMBR=002,CUADD=0,PATH=(22), UNITADD=((00,2)),UNIT=SCTC,LINK=(CB) *** IODEVICE STATEMENTS *** IODEVICE ADDRESS=(200,2),UNIT=SCTC IOCDS – LPAR 1 *** CHPID STATEMENTS *** CHPID PATH=((22)),TYPE=CNC,SWITCH=01,SHARED *** CNTLUNIT STATEMENTS ***...
  • Page 47: Tcp/Ip Routing

    TCP/IP Routing TCP/IP Direct Connect is a Network Driver Interface Specification (NDIS) compliant adapter driver. TCP/IP Direct Connect makes the PCI ESCON Adapter appear exactly like any other Network Interface Card (NIC) to the Windows server. As a result when TCP/IP Direct Connect and a PCI ESCON Adapter are installed along with one or more Local Area Network (LAN) adapters the Windows server becomes a multihomed system.
  • Page 48 Subnet 0 Subnet 1 Subnet 2 Subnet 3 As shown, the Ethernet segment makes up subnet 0 and the Token-Ring makes up subnet 1. Subnets 2 and 3 are currently not used. The router’s Ethernet port is assigned an IP address in Subnet 0 and the Token-Ring port is assigned an address in subnet 1.
  • Page 49 Figure 5-26. TCP/IP Direct Connect Configuration Screens Notice also that the subnet these two addresses are in is different than the subnet of the server’s LAN adapter (207.168.12.68). Microsoft’s TCP/IP stack can be configured to automatically forward IP packets between network adapters as long as those adapters are in different subnets.
  • Page 50: Updating Workstation Configurations

    Updating Workstation Configurations In most existing networks today it will not be necessary to update the TCP/IP configuration on a workstation in order to allow it to connect to the mainframe using an ESCON adapter and TCP/IP Direct Connect. Most workstations already point to an existing router and/or server as a default gateway and that will be all that is needed.
  • Page 51 Figure 5-28. Windows 95 TCP/IP Properties TCP/IP Direct Connect 45...
  • Page 53: Chapter 6. Troubleshooting

    Chapter 6. T ROUBLESHOOTING If your PCI ESCON Adapter fails to initiate successfully this chapter will provide you with some general troubleshooting guidelines to help you identify and fix your problem. If after you have been through this troubleshooting chapter you are still unable to make your adapter work properly please refer to the section titled “Help and Service Information”...
  • Page 54 STEP 1. With your server powered on, check to make sure both LEDs are lit. If the top LED is Green and the bottom LED is Orange then the adapter has successfully completed POST and loaded firmware. This is the normal condition prior to starting the software.
  • Page 55: Escon Configuration

    ESCON Configuration When the adapter loads the emulation it also loads the ESCON device configuration (see Chapter 4.). This configuration must match the configuration defined on your mainframe(s). In Windows 2000 you may display an ESCON adapter’s device configuration using the Device Manager in the Computer Management utility (Figure 6-1).
  • Page 56 Highlight the ESCON adapter and click Properties. Figure 6-3. ESCON Device Configuration The ESCON Devices tab shows the devices configured for this adapter. Verify that the units defined here match those defined on the mainframe. Make sure you are using the correct device numbers in upper layers of software. Correct any discrepancies you find and reset the server.
  • Page 57: Tcp/Ip Direct Connect

    TCP/IP Direct Connect If TCP/IP Direct Connect is configured with a link type of HSAS or MPCPTP, please refer to the section titled “Troubleshooting” in the “MPC+ for Windows NT Installation Guide”. In Windows 2000 the easiest way to tell if TCP/IP Direct Connect has failed to activate is to look at the system’s console(Figure 6-4).
  • Page 58 Figure 6-5. TCP/IP Direct Connect Properties ; CTC connection DEVICE DEVCTC1 CTC a40 LINK LINKCTC1 CTC 0 DEVCTC1 HOME 207.169.12.129 LINKCTC1 GATEWAY ; Direct Routes - Routes that are directly connected to my interfaces. ; Network First Hop 207.169.12.130 = START DEVCTC1 Figure 6-6.
  • Page 59: Help And Service Information

    Help and Service Information If you have questions about your new Bus-Tech product, or require technical assistance, visit the Bus-Tech Web site at http:\\www.bustech.com. You can also get help and information through the Bus-Tech’s Technical Support line, Monday through Friday, 8:30 am – 5:00pm Eastern time. Response time may vary depending on the number and nature of the calls received.
  • Page 60: Step 3: Placing The Call

    If possible, be at your computer. Your technical support representative might want to walk you through the problem during the call. Step 3: Placing the Call If you call after your warranty or maintenance contract has expired, you might be charged a fee.
  • Page 61: Customer Response

    BURLINGTON, MA 01803 ATTENTION: CUSTOMER SUPPORT Or, call us at: (781) 272-8200 FAX: (781) 272-0342. Or, visit our Web Site at: www.bustech.com Bus-Tech PCI ESCON Adapter Installation Guide Sixth Edition (January 2001) Part Number 40-01459-D0-001 Help and Service Information 55...
  • Page 63: Technical Specifications

    Technical Specifications Physical Attributes Dimensions Power Requirements Operating Temperature Standards Connectors ESCON Serial Port Software On Board Emulations Available Device Drivers and APIs Optional Data Link Drivers Standard Full Size PCI Adapter Length 12.283” Height 4.2” 5.5 Amp. at + 5V DC 20 mAmp.