OWNER' S MANUAL
WIRE CONTROLLER OF AIR CONDITIONER
MODEL: KJR-12B/DPBG(T)-E
Brivis Part No:B026000
Brivis Climate Systems Pty Ltd
Tel:1300 BRIVIS
brivis.com.au
Thank you very much for purchasing our product.
Before using your unit, please read this manual carefully and keep it for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for Brivis KJR-12B/DPBGT-E

  • Page 1 OWNER’ S MANUAL WIRE CONTROLLER OF AIR CONDITIONER MODEL: KJR-12B/DPBG(T)-E Brivis Part No:B026000 Brivis Climate Systems Pty Ltd Tel:1300 BRIVIS brivis.com.au Thank you very much for purchasing our product. Before using your unit, please read this manual carefully and keep it for future reference.
  • Page 3 ● This manual gives detailed description of the precautions that should be brought to your attention during operation. ● In order to ensure correct service of the wired controller please read this manual carefully before using the unit. ● For convenience of future reference, keep this manual after reading it.
  • Page 4: Table Of Contents

    CONTENTS 1. SAFETY PRECAUTION................1 2. SUMMARIZE....................2 3. FUNCTION SUMMARY................2 4. NAME AND FUNCTION OF INDICATORS ON THE WIRE CONTROLLER.................... 3 5. INSTALLATION METHOD................4 6. NAME AND OPERATION OF THE BUTTON ON THE WIRE CONTROL- LER......................5 7.
  • Page 5: Safety Precaution

    1. SAFETY PRECAUTIONS The following contents are stated on the product and the operation manual, including usage, precautions against personal harm and property loss, and the methods of using the product correctly and safely. After fully understanding the following contents (identifiers and icons), read the text body and observe the following rules.
  • Page 6: Summarize

    Warning Please entrust the distributor or professionals to install the unit. The installers must have the relevant know-how. Delegate Improper installation performed by the user without perm installation Warning arning ission may cause fire, electric,shock, personal injury or water leakage. Do not spray flammable aerosol to the wire Forbid controller directly.
  • Page 7: Controller

    4. NAME AND FUCTION OF INDICATORS ON THE CONTROLLER Operation mode indication Follow me function ON/OFF indication Fan speed indication Lock Timer ON/OFF Temperature display zone ① Operation mode indication: When adjust setting off time or only off When press " MODE " button, the follow- time is set , the "OFF"...
  • Page 8: Installation Method

    the same as setting temperature. It is speed. available under cooling, heating, auto ⑥ Lock: mode. When the " LOCK " button is pressed, ④ ON/OFF indication : the icon appear and other buttons is When is on, the icon display, unable, press again, the icon disappear.
  • Page 9: Name And Operation Of The Button On The Wire Control- Ler

    When a wire controller is needed, a small 5-way terminal should be added, fix an infrared emitter with gumwater near the receiver on the switch board. Connect its anode and cathode to A and B,and +5V, GND, RUN to C, D, E on the switch board. 6.
  • Page 10 When under cool, heat and auto mode, ① Mode botton: press this button, follow me function is When press this botton, the operation active. Press again, this function is mode change following ineffective. sequence: ⑥ Turbo button : →AUTO → COOL→DRY→HEAT→FAN If press this button in cooling mode, the Remark: For the cooling only model, the fan speed will increase (available to some...
  • Page 11: Using Method

    want to prevent setting from being changed accidentally or play fully. Push the LOCK button again when you want to ⑩ Adjust button ▲: cancel the LOCK mode. Set indoor temperature up. If press and hold on, it will increase at 1 degree per 7.
  • Page 12: Dry Operation

    1. Press "MODE" button, select "COOL" , Timer on only: "HEAT" or "FAN ONLY" mode. 1. Press " TIME ON " button, it display 2. Press temperature adjust button to "SET" on LCD, and display " H " and select setting temp.. "ON"...
  • Page 13: Change Timer

    1. Set timer on time as the corresponding 8. TECHNICAL INDICA- step1 and 2. TION AND REQUIRE- 2. Set timer off time as the corresponding MENT step1 and 2. 3. Timer off time must be longer than 1.EMI and EMC comply to CE, timer on time.
  • Page 14 Version: QS01X-002BW 202000100350...
  • Page 19 OWNER’ S MANUAL Brivis Ducted Inverter Programmable Controller Brivis Part No:B026001 Brivis Climate Systems Pty Ltd Tel:1300 BRIVIS brivis.com.au Thank you very much for purchasing our product. Before using your unit, please read this manual carefully and keep it for future reference.
  • Page 21 ● This manual provides a detailed description of the precautions that should be brought to your attention during operation. ● In order to ensure correct service of the wired controller please read this manual carefully before using the unit. ● For future reference, keep this manual in a safe place after reading it.
  • Page 22 CONTENTS 1. SAFETY PRECAUTION................1 2. SUMMARISE....................2 3. FUNCTION SUMMARY................2 4. NAME AND FUNCTION OF INDICATORS ON THE CONTROLLER..3 5. INSTALLATION METHOD................4 6. NAME AND OPERATION OF THE CONTROLLER BUTTONS....5 7. METHOD OF OPERATION................. 7 SET TIME....................
  • Page 23: Safety Precaution

    1. SAFETY PRECAUTIONS The following contents are stated on the product and the operation manual, including usage, precautions against personal harm and property loss, and the methods of using the product correctly and safely. After fully understanding the following contents (identifiers and icons), read the text and observe the following rules.
  • Page 24: Function Summary

    Warning Only suitably authorised and trained professionals should install the unit. Delegate Improper installation performed by the user without Warning arning installation permission may cause fire, electric,shock, personal injury or water leak. Do not spray flammable aerosols onto the wired Forbid controller directly.
  • Page 25 4. DISPLAY NAME AND FUNCTION ON PROGRAMMABLE CONTROLLER Day of Week Lock Operation mode Period Time Date Error Temperature Timer on/off ①Operational mode indication: ③Fault indication. By pressing "MODE" then either "ADD" ④Temperature indication. or "REDUCE", the mode of operation ⑤Programmable Controller switch can be changed/cycled: indication.
  • Page 27 6. BUTTON NAME AND OPERATION OF THE PROGRAMMABLE CONTROLLER ① Mode button: By pressing "MODE" then either "ADD" ②Fan speed button: press this button or "REDUCE", the mode of operation and "ADD" or "REDUCE" to select can be changed/cycled: High, Middle, Low or Auto fan speed. To Cool =>...
  • Page 28 ④Date button: In the interim or normal display mode, press the button, and ⑧Cancel button: Used to exit without saving then enter the date, the sequence is a change/setting, or to cancel the lock. year--month--day of the week. ⑨Query button: Press “QUERY” to select temperature values, press "CANCEL"...
  • Page 29: Set Time

    SET DATE adjust the minutes. Press "ADD" or adjust minutes, "REDUCE" press "CONFIRM" to save and go back. DATE 7. CONTROLLER SETUP set year REDUCE SET TIME CONFIRM TIME set month REDUCE set hours REDUCE CONFIRM CONFIRM set day of the REDUCE set minutes REDUCE...
  • Page 30: Set Mode

    SET FAN SPEED *Unit must be on to set fan speed NOTE Press "CANCEL" button to go back to the previous step, or the normal display screen. select fan speed REDUCE to save and exit CONFIRM SET MODE MODE NOTE Press "CANCEL"...
  • Page 31: Query Plan / Program

    QUERY PLAN SET PLAN EDIT QUERY select day of select day of REDUCE REDUCE the week the week CONFIRM CONFIRM select the start => select period REDUCE REDUCE hour of the first period display various param- CONFIRM CONFIRM eters of the selected period back select the start...
  • Page 32 from previous page CONFIRM select mode REDUCE CONFIRM select fan speed REDUCE CONFIRM select temperature REDUCE setting of the first period is done CONFIRM Press "CONFIRM" button REDUCE for 3 to 5 seconds to return to the 'select day of the week' step directly. Set the parameters of the next period *=>...
  • Page 33: Technical Indication And Requirement

    If selecting "AUTO" in the fan mode in some time periods, the 'auto' fan fan speed will not be displayed. However, the fan will operate in "AUTO" mode but the controller will display "CURRENTLY". 8. TECHNICAL INDICATION AND REQUIREMENT EMI and EMC comply to CE 9.
  • Page 34: Table Of Protection States / Faults

    10. TABLE OF PROTECTION STATES / FAULTS Protection states Description Other protection Compressor overcurrent Power supply over-under voltage protection Low pressure protection High pressure protection Supply air temperature protection Compressor temperature protection Condensing Unit high temperature protection Anti-cool supply air or defrost protection Evaporator temperature protection...
  • Page 35 End Document Brivis Climate Systems www.brivis.com.au Tel: 1300 BRIVIS Tel: 1300 274847 September 2012...