The ATP1000 lets you control all programming and operation of compatible security systems
(see the "Specifications" section).
The large 2-line, 16-character display provides easy to read messages to indicate the current sta-
tus of the system. The touchpad includes police, fire, and auxiliary panic buttons that can be acti-
vated anytime. A built-in speaker provides alarm, status, and button-press sounds. A swing-
down door reveals a label with basic system operating commands. The door can be removed by
simply opening it past its stop point. The door can also be reattached later if desired.
Tools and Equipment Needed
•
4-conductor, 22- or 18-gauge wire
•
Screwdriver
•
#6 screws and anchors (included)
•
Panhead screws for gang box installation
•
Saw or utility knife for cutting wallboard
Guidelines
•
Mount the touchpad in an environmentally controlled area (32°F to 120°F/0°C to 49°C).
•
When mounting the touchpad, allow at least 3 inches below it for the swing-down cover.
•
Do not exceed the maximum available power. See the panel installation instructions for max-
imum available power.
•
Table 1 describes the power used by the touchpad.
•
Table 2 describes the maximum wire lengths allowed between the touchpad and the panel.
Table 1: Touchpad Power Usage
Current (mA)
110
Maximum alarm current with the
buzzer sounding and the touchpad
illuminated from a button press
60
Typical operation
12
Power saving mode (no panel AC
power)
Table 2: Maximum Touchpad Wire Lengths
Wire Gauge
Max. Touchpad Wire Length
(Unshielded or
Between Touchpad and Panel
Shielded)
18
750 feet
22
300 feet
$73 7RXFKSDG'LVSOD\
Conditions
,QVWDOODWLRQ ,QVWUXFWLRQV
'RFXPHQW 1XPEHU 5HY $
2FWREHU
1
Need help?
Do you have a question about the ATP1000 and is the answer not in the manual?
Questions and answers
Manual de uso
The user manual for the GE Interlogix ATP1000 provides information on installation, power requirements, operating conditions, and troubleshooting for the ATP1000 touchpad. It includes instructions for resetting the system, compatibility details with Concord panels, and specifications such as power requirements (12 VDC nominal), temperature range (32°F to 120°F), and humidity tolerance (95% relative, non-condensing). It also covers UL listings for fire and burglar alarm compliance.
This answer is automatically generated