TROUBLESHOOTING
MOTOR WILL NOT START
CAUSE
Unit is unplugged
Starter button or bail improperly used
Overload protection switch has popped out
NOTE:
For maintenance beyond the minor adjustments listed above, or for replacement parts, please
call the Customer Support Department at 1-866-206-2707 (U.S.) or 1-877-696-5533 (Canada).
MOTOR*
Motor Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electric, Corded
Motor Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 VAC
Motor Amperage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 Amps
Operating RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to 8,000 rpm
Ignition Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bail Lock Safety Button
Overload Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 V 5 amp Breaker
CULTIVATOR*
Drive Shaft Tube. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Steel Tube
Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Steel Tube
Cultivating Path Width (Maximum) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 inches (22.86 cm)
Cultivating Depth (Maximum) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 inches (12.70 cm)
Approximate Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 lb. (12.25 kg)
* All specifications are based on the latest product information available at the time of printing. We
reserve the right to make changes at any time without notice.
4
SOLUTION
Make sure that extension cord is securely plugged
into cultivator's cord outlet receptacle on one end
and a 110V outlet on the opposite end.
Press starter button and hold it in while
squeezing bail against the handle.
Depress overload protection switch. Follow
starting instructions.