Advertisement

Quick Links

GSM
GSM
GSM
GSM Home/Business
Profile
Profile
Profile
Profile
For a better understanding of this product, please read this user manual thoroughly before using it.
Home/Business
Home/Business
Home/Business Alarm
User
User
User

User Manual

(LS-GSM-006)
(LS-GSM-006)
(LS-GSM-006)
(LS-GSM-006)
Alarm
Alarm
Alarm System
Manual
Manual
Manual
- 1 -
System
System
System

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LS-GSM-006 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lenser LS-GSM-006

  • Page 1: User Manual

    Home/Business Alarm Alarm System System User Manual User Manual User User Manual Manual (LS-GSM-006) (LS-GSM-006) (LS-GSM-006) (LS-GSM-006) Profile Profile Profile Profile For a better understanding of this product, please read this user manual thoroughly before using it. - 1 -...
  • Page 2: Table Of Contents

    Catalogue Catalogue Catalogue: : : : Catalogue Function Introduction SMS Number Setting Alarm Host Diagram Delete SMS Receiving Number Functions Settings Defense Zone Programming Initialization Home Arm Defense Zone Setting Enter Settings Artificial Voice Recording Exit Settings Siren Setting Operation Instructions Factory Reset Coding of Remote Controller System Status...
  • Page 3: Function Introduction

    Delete Phone Number Technical Parameters Function Instruction: Function Function Function Instruction: Instruction: Instruction: � 7 wired and 99 wireless defense zones; � LCD screen with time clock display; � Voice prompt for all operations; � 3 groups of timely arm and disarm; �...
  • Page 4: Alarm Host Diagram

    Alarm Alarm Host Host Diagram Diagram Alarm Alarm Host Host Diagram Diagram In order to make the main unit get the wireless signal well for all wireless accessories, please put the alarm host at the central place of your defense area. Make sure it’s away from large metal objects and household appliances which may cause high frequency interference, as well as barriers such as reinforced concrete wall or fire door, etc.
  • Page 5: Functions Settings

    display: LCD display: display: display: Function Function tings tings Function Function Set Settings tings � � � � Initialization Please insert SIM card and plug in power adaptor, and then power on the system, all the LED lights will be on for 2 seconds and you will hear a long beep; the system comes into initialization.
  • Page 6: Enter Settings

    Finally, turn on the backup battery switch. � � � � Enter Settings In the state of disarm, input 4-digit password by the keypad on the main unit and press [# # # # ] button to confirm. You will hear a voice prompt: please enter instruction. At the same time, [SET SET] indicator is on without flashing and [0000] displays on the screen, indicating the system enters setting status.
  • Page 7: Factory Reset

    � Factory Reset 95175308246 95175308246 95175308246] and press [# # # # ] to confirm, all the In disarm status, use keypad to input [95175308246 LED indicators will be on for 2 seconds and you will hear a long beep. The main unit gets all its settings cleared and restores to its factory settings successfully.
  • Page 8: Delete Remote Controller

    � Delete Remote Controller remote remote controller controller can’ ’ ’ ’ t t t t control control control main main unit unit after after after it it it it’ ’ ’ ’ s s s s deleted deleted deleted The remote remote controller controller can...
  • Page 9: Delete Defense Zone

    The wireless wireless wireless wireless detector detector detector detector can can’ ’ ’ ’ t t t t control control control control the the main main main main unit unit unit unit after after after after it it it it’ ’ ’ ’ s s s s deleted deleted deleted deleted .
  • Page 10: Change Program Password

    2 Change Program Password Program Program password password password is is is is the password password should should input input input in in in in order order order order to to to to Program Program password the password password you you should should input setup...
  • Page 11: Timing Settings

    and a voice prompt “setting finished”. FF]�[# # # # ] [32]�[AA AA]�[BB BB]�[CC CC]�[DD DD]�[EE EE]�[FF Operating method: AA indicates: the last 2 digits of the present year BB indicates: the 2 digits of the present month CC indicates: the 2 digits of the present date DD indicates: the 2 digits of the present hour EE indicates: the 2 digits of the present minute FF indicates: the 2 digits of the present second...
  • Page 12: Timely Disarm

    [33]�[22 22 22 22]�[45 45 45 45]�[# # # # ] Operating method: LCD display: 2) Timely Disarm In setup status, use keypad to input [36~38], then input the hour [AA] and minute [BB] of the time you want to set to disarm, and finally input [#] to confirm. You will hear a long beep and a voice prompt “setting finished”.
  • Page 13: Alarm Number Setting

    [39]�[0/1 0/1]�[# # # # ] Operating method: 0: turn off the function of timely arm/ disarm 1: turn on the function of timely arm/ disarm For example: turn on the function of timely arm/ disarm [39]�[1 1 1 1 ]�[# # # # ] Operating method: �...
  • Page 14: Lcd Display

    finished”, which indicate the alarming user number is deleted successfully. � Operating method: [XX [# # # # ] XX indicates: : : : the 1- 6 alarming user number [51 51 51 51] ~ [56 56 56 56] For example: Delete the third alarming user number from the system. �...
  • Page 15: Delete Sms Receiving Number

    � Delete SMS Receiving Number In setup state, use keypad to input [57 57 57 57] ~ [59 59 59 59], and then press [# # # # ] button to confirm. The main unit will make a beep, the [Signal Signal Signal Signal] indicator will flicker once and you will...
  • Page 16: Home Arm Defense Zone Setting

    C: C: C: defense zone location [1 1 1 1 ] SOS Alarm [2 2 2 2 ] Fire Alarm [3 3 3 3 ] Gas Leak Alarm [4 4 4 4 ] Door Alarm [5 5 5 5 ] Hall Alarm [6 6 6 6 ] Window Alarm [7 7 7 7 ] Balcony Alarm [8 8 8 8 ] Perimeter Alarm...
  • Page 17: Artificial Voice Recording

    � � � Operating method: [61 61 61 61] [12 12 12 12] [0 0 0 0 ] [# # # # ] � Artificial Voice Recording In setup state, use keypad to input [701 701], and then press [# # # # ] to confirm. The main unit will emit a beep and the [ ] indicator is on, and after 10 seconds countdown, recording starts: record at 30cm away from the main unit with moderate tone;...
  • Page 18: Operation Instructions

    Operat Operat Instructions Instructions Operat Operation ion Instructions Instructions � System status There are 4 status as following: � Arm: defense zone 1~99 will alarm when detectors are triggered � � � � Home Arm: in arm status, the defense zone which is set as [Home Arm] will alarm when detectors are triggered.
  • Page 19: Out Arm

    � Emergency Alarm: Press button, system will alarm at once. � Out Arm It means to guard all around your house while everyone is going out; all the detectors of the host are always working; when the detector is triggered by detecting source (anti-theft, fire prevention, gas leak, etc.), the alarm system will sound the alarm.
  • Page 20: Disarm

    LCD display: � Disarm It means to stop the alarm when the main unit sounds the alarm or make the alarm system in the state of non-warning. After disarming, even if you trigger the detector, the main unit would not sound alarm (excluding 24-hour defense areas). Use keypad to input system password, then press [# # # # ] button.
  • Page 21: Remote Control

    If you hang-up directly without answering the call, the system will call each preset number for 3 times circularly. Press [*]: Read the alarm information. Press [1]: Main unit stops alarming and Arm; it stops calling users. Press [2]: Main unit stops alarming and Disarm; it stops calling users. Press [3]: Siren off and monitors the scene for 30 seconds;...
  • Page 22: Emergency Help

    Press [4]: two-way intercom for 30 seconds. You can’t operate the main unit during this time. � Emergency Help Press [Emergency ] button on keypad, or [ ] button on remote controller or wireless panic button, the main unit will alarm and make call to the preset user numbers.
  • Page 23: Maintenance

    For example: the 51st defense zone; the 7th alarming; alarming time: 12:10, August 1st, 2008. LCE display one second, and then display the alarming time: GSM Signal Signal Signal Signal Checking Checking Checking Checking Before installing the main unit, you should check the signal of the installing place in order to ensure the unit can perform well.
  • Page 24: Notes

    detector once a month; if not permitted by condition, you should check it at least every three months. Check the main unit: Whether it can arm/disarm normally. Whether it can dial the number for alarm normally. Whether it can receive wireless detectors’ signal normally Whether the back-up battery can work normally.
  • Page 25 � List 1: Input Voltage DC12V/1A Standby Current <55mA Alarming Current <450mA Wireless Frequency 433MHz, 2262/4.7MΩ GSM Frequency 900/ 1800/ 1900MHz Back-up Battery NI-HI AAA*6 DC7.2V Siren Volume 110dB � List 2: Defense Alarm Home Arm Type Siren Zone Information Zone 1 effective invalid...
  • Page 26 Zone 7-99 effective invalid real-time Emergency alarm Wired effective invalid real-time Emergency defense zone alarm (96-99) Operation Password 8888 Remote control Remote control Password 1234 Siren Siren sound time 180 sec. Home Appliance Optional - 26 -...