4x6 Amplified AV System Aria By Channel Vision A4623 4x6 Amplified AV System Aria By Channel Vision A4623R A4623 A4623R 4-input 6-zone Amplified AV System...
Page 2
The A4623/A4623R is a 4 input 6 zone matrix A/V controller with an integrated amplifier designed for whole-house audio/video distribution. The unit provides both pre-amp outputs and speaker level outputs for each of the 6 zones making it easy to add a higher power amplifier for more demanding applications.
IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions for future reference 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this device near water. 6. Clean only with a dry cloth. 7 Do not block any ventilation openings. Install in accordance with these instructions.
Page 4
Vid 3 Vid 4 Mute Connecting a standard IR repeater to the A4623... A standard IR repeating device may be connected directly to the A4623 allowing the unit to be controlled from a learning IR remote. The connection is similar to the wiring configuration shown above for the A0127, except there are only three wires as shown below.
Page 5
Using the A0505 remote control... The A0505 is designed to allow you to control your A4623 without having to touch the buttons on the A0127. Simply point the A0501 remote control at the IR sensor located at the bottom of the A0127 and press the desired button.
Page 6
A4623 Re Each zone is controlled through the A0127 keypad which connects to the RJ-45 jacks on the rear panel. See page 4 for connection details Connect serial data controller to the Serial port (Hex codes on pages 8-11) 6 Control 5...
Page 7
DO NOT OPEN T3.15AL/250V 115VAC Main Power Fuse IR Link allows two A4623 units to be joined so that IR signals picked up by the keypads of the first unit can be shared to the second unit. The IR-4180 cable can be used to link two units together.
Page 8
RS-232 Control Code: For installations requiring more sophistication the A4623 supports RS-232 making it well suited for use with automation systems. Baud Rate: 19200, 8N1 (8Bit Data, No Parity, 1 Stop Bit) Each transmission = 8 ASCII bytes Check Sum = The sum of the first 7 bytes inverted and truncated Note: the check sum for each command is included in the following charts.
Page 9
Zone 2 Commands Function Hex Command ASCII Command Zone 2 Power Toggle A46Z2PL’ 41 34 36 5A 32 50 4C 2C A46Z2PA7 41 34 36 5A 32 50 41 37 All Power Toggle A46Z2S1D 41 34 36 5A 32 53 31 44 Zone 2, Select Source 1 A46Z2S2C 41 34 36 5A 32 53 32 43...
Page 10
Zone 4 Commands Function Hex Command ASCII Command Zone 4 Power Toggle A46Z4PL* 41 34 36 5A 34 50 4C 2A A46Z4PA5 41 34 36 5A 34 50 41 35 All Power Toggle A46Z4S1B 41 34 36 5A 34 53 31 42 Zone 4, Select Source 1 A46Z4S2A 41 34 36 5A 34 53 32 41...
Page 11
Zone 6 Commands Function Hex Command ASCII Command Zone 6 Power Toggle A46Z6PL( 41 34 36 5A 36 50 4C 28 A46Z6PA3 41 34 36 5A 36 50 41 33 All Power Toggle A46Z6S1@ 41 34 36 5A 36 53 31 40 Zone 6, Select Source 1 A46Z6S2? 41 34 36 5A 36 53 32 3F...