Dometic CK400
5

Technical description

The extractor hood CK400 removes odours and steam that arises during
cooking. The device is equipped with a removable and washable filter, two
built-in halogen lamps and a fan with two power levels. It is connected via a
flexible pipeline with the interior area and can be mounted on the roof of the
motorhome due to its weather-resistant cover cap.
5.1
Control elements
No. in
fig. 2,
Description
page 3
1
Filter
2
Fan On/Off switch
3
Light On/Off switch
4
Halogen lamps
6

Mounting the extractor hood

Note on installation location
The extractor hood should preferably be mounted above the cooking zone
and built into a suspended cabinet if possible. The distance between the gas
hob flame and the extractor hood must be at least 50 cm.
The fan should be mounted on the roof on a level surface. When mounted on
a sloping surface, the roof hood must be rotated so that one of the three wa-
ter drainage holes is directed toward the incline. A tilt angle up to 20° will not
affect the performance of the fan when the motor is not running.
6.1
Mounting the fan
➤ Select an appropriate installation location for the fan on the roof.
➤ Draw the location and size of the opening of 105 mm diameter (fig. 3,
page 3).
➤ Pre-drill and cut out the hole on the roof carefully with a keyhole saw or
similar tool.