Malfunction Code - Daikin FXDQ20PVE Operation Manual

Vrv system inverter
Table of Contents

Advertisement

(1) Use a vacuum cleaner (A) or wash the air filter
(B) to remove dust and trash.
(A) Remove dust and trash using a vacuum
cleaner.
(B) Wash it with water.
When the air filter is very dirty, use a soft brush
and neutral detergent.
Dewater and dry in the shade.
3. Attach the air filter.
4. Push the "filter sign reset" button on the
remote controller.
The display "
" vanishes.
〈Cleaning the air outlet and exterior〉
CAUTION
• Do not use gasoline, benzene, thinner, polish-
ing powder or liquid insecticide.
• Do not use hot water of 50°C or higher, as doing
so may result in discoloration or deformation.
(1) Clean with dry soft cloth.
(When it is difficult to remove stains, use water
or neutral detergent.)
If the following phenomenon occurs, con-
tact your dealer.
WARNING
• When any abnormality is found (burnt odor),
turn off the power switch.
Continued operation under such circumstances
may result in a failure, electric shock or fire.
• Contact your dealer.
Phenomenon
• If a safety device such as a fuse, a breaker or an
earth leakage breaker frequently actuates;
Take the following actions before contact.
Do not turn on the main power switch.
• If the ON/OFF switch does not properly work;
Take the following actions before contact.
Turn off the main power switch.
3
Phenomenon
• Water leaks out from the air conditioner.
Take the following actions before contact.
Stop the operation.
Phenomenon
• The "OPERATION lamp", "INSPECTION dis-
play" or "UNIT No." is winking and lit, and "MAL-
FUNCTION CODE" is displayed.
UNIT No.
C
INSPECTION
display
Take the following actions before contact.
Inform the dealer of the details being displayed
on the remote controller.
Product type and running noise
Model No.
FXDQ20PVE
Model
Function
Combination
system
Condenser
cooling method
Type
Air blowing
method
Rated cooling
2200
capacity (W)
Rated heating
2500
capacity (W)
Operating sound dB
(A) (conversion values
33
under noise-less room)
Explanation
• The actual value during operation is higher than
the indicated value under the influence of envi-
ronmental noise and echo.
• The above data is subject to change by means
of technological innovation.
• The operating sound is based on the rear side suc-
tion inlet, and the external static pressure 10Pa.
Operating sound for under suction inlet:
[operating sound for rear side suction inlet] + 5dB.
However, when installation to which the external
static pressure becomes low is carried out 5dB or
more may go up.
OPERATION lamp
L
H
INDOOR UNIT No. in
which a malfunction occurs

MALFUNCTION CODE

FXDQ25PVE
FXDQ32PVE
Heat pump type
Separate type
Air cooling type
Direct air-blowing type
2800
3600
3200
4000
33
33
English