Advertisement

Video Matrix Switch Series
PIH-816III/832III/864III
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Lilin PIH-832III

  • Page 1 Video Matrix Switch Series PIH-816III/832III/864III INSTRUCTION MANUAL...
  • Page 2: Table Of Contents

    CONTENTS Features ............................1 Warnings & Cautions ..........................2 Connection Panel ..........................3 System Diagram ..........................4 System Connection ..........................5 Operation Monitor Display On Power Up .......................6 Setup Mode ..........................6 Setting Time & Date ........................7 Setting Password ........................8 Deleting Password ........................8 Setting Sequence Table .......................9 Setting Monitor ...........................9...
  • Page 3: Features

    Each Fast Dome can set up to 4 groups of preset points. PIH-816III : 16 alarm inputs and 1 alarm outputs PIH-832III : 32 alarm inputs and 1 alarm outputs PIH-864III : 64 alarm inputs and 1 alarm outputs Buzzer and warning display under video loss or alarm situation.
  • Page 4: Warnings & Cautions

    WARNINGS & CAUTIONS Please read the manual before attempting installation or operation 1. Please be aware of the warning and caution notices. 2. Don't use any chemical detergent to clean the machine surface, use a damp cotton cloth only. 3. Please install the Matrix in a dry area, water and high humidity may cause damage of internal parts. An external housing should be used for outdoor installation.
  • Page 5: Connection Panel

    RS232 ALARM IN ALARM KEY BOARD VIDEO LOST MLP1 MLP2 RECEIVER AC IN VIDEO IN VIDEO OUT PIH-832III (32 video inputs, 8 video outputs) RS232 ALARM IN ALARM KEY BOARD VIDEO LOST MLP1 MLP2 RECEIVER AC IN VIDEO IN VIDEO OUT...
  • Page 6: System Diagram

    SYSTEM DIAGRAM RS485 RS485 Fast Domes Pan/Tilt Co-Axial RS485 RS485 Co-Axial PIH-820 Receiver Control Lines Co-Axial RS485 Cameras RS485 Co-Axial DA Y NIG Co-Axial PIH-820 Receiver Control Lines RS485 Co-Axial DA Y NIG RS485 Co-Axial Co-Axial PIH-820 DA Y NIG Receiver Control Lines...
  • Page 7: System Connection

    SYSTEM CONNECTION The Matrix System has the ability to process multi-input video signals and control up to 64 external RS-485 receivers and Fast Domes via twist pair cable. Matrix and Fast Domes/RS-485 Receiver connection Connection of first Dome/Receiver to Matrix: TXD+ of RECEIVER connector located at the back of matrix system should be connected to TXDI+ on Dome/Receiver.
  • Page 8: Operation

    OPERATION Monitor Display When Power Up 1st Video input must be connected when power up the system. Otherwise unreadable codes will be displayed. Remaining Video inputs may be connected randomly. When matrix is powered up, the system will perform an auto-test including video-input signals, and non-connected Video-input will be displayed(See diagram below).
  • Page 9: Setting Time & Date

    4. ID & RECEIVER SETUP: SETUP MENU To set camera ID and Receiver number. 1. SYSTEM SETUP 2. SEQUENCE TABLE 3. MONITOR SETUP 5. ALARM SETUP: 4. ID & RECEIVER SETUP 5. ALARM SETUP To set up corresponding alarm and camera. 6.
  • Page 10: Setting Password

    Setting Password For security reason, password can be set up as follows: SYSTEM SETUP SETUP MENU PASSWORD SETUP 1. SYSTEM SETUP ENTER NEW PASSWORD 1. DATE / TIME SETUP Enter Password 2. SEQUENCE TABLE 2. PASSWORD SETUP 3. MONITOR SETUP 3.
  • Page 11: Setting Sequence Table

    Setting Sequence Table 16 sequence tables can be set in this Matrix System. Each sequence table contains 32 positions allowing set up of 32 cameras and corresponding dwell time. Each SEQUENCE TABLE can be assigned to different monitors as follows. Note: Monitor will only display cameras with dwell time set up in each sequence table when GLOBAL DWELL TIME in MONITOR SETUP is set to 0 sec.
  • Page 12: Id & Receiver Setup

    1. Press numeric key 3 to enter MONITOR SETUP from SETUP MENU. 2. Press numeric key 2 followed by ENT key. The 2nd monitor is selected as shown above. (1~16 monitors can be selected depending on the model purchased) 3. Use blinking cursor to set up after monitor is selected. Press numeric key 1 followed by ENT key to set 1st sequence table.
  • Page 13: Alarm Setup (Alarm And Corresponding Camera)

    1. Press numeric key 4 to enter ID & RECEIVER SETUP from SETUP MANU. 2. Press numeric key 1 followed by ENT key from ID & RECEIVER SETUP, to select 1st camera/receiver. (Up to 64 cameras/receiver can be selected. Depend on the model. See MENU shown above) 3.
  • Page 14: Alarm Time Setup

    Preset NO: 4 should correspond with 4th alarm input. Preset NO: 5 should correspond with 5th alarm input. Preset NO: 6 should correspond with 6th alarm input. If alarm from matrix was linked to a Fast Dome Camera then PRESET NO should start from 7 and onward. (If the dome also has alarms connected.) 1st Alarm input of Matrix corresponding to 7th preset position of Fast Dome.
  • Page 15: Dome Setup (Fast Dome)

    Dome Setup (Fast Dome) Matrix can connect to Fast Dome Cameras. 128 preset positions can be set for a Fast Dome Camera. As follows: DOME SETUP DOME SETUP SETUP MENU DOME NO 1 DOME NO 1 1. SYSTEM SETUP 2. SEQUENCE TABLE RESET <...
  • Page 16 3. Set 17~128 presets as follows: DOME SETUP DOME SETUP DOME NO 1 DOME NO 1 RESET < Y/N > N RESET < Y/N > N PRESET NO PRESET No 17 < 1 TO 128 > DWELL <SEC.> < 0 TO 255 > SPEED <1/SEC.>...
  • Page 17: Recalling Monitor Or Camera

    Recalling Monitor or Camera The Matrix can switch up to 16 monitors and 64 cameras. It is necessary to recall a monitor then the camera to gain control: MON 01 <H> 10/13/98 MON 01 <H> 10/13/98 CAM 01>CAMERA01 17 28 01 CAM 01>CAMERA01 17 28 01 Enter MON...
  • Page 18: Controlling Ptz Or Fast Dome Camera

    Controlling Scanner or Fast Dome Camera Manual control Scanner or Fast Dome Camera as follows: MON 01 <H> 10/13/98 MON 01 <H> 10/13/98 CAM 01>CAMERA01 17 28 01 CAM 01>CAMERA01 17 28 01 < Select the monitor and camera first. If Fast Dome Camera or Scanner is set as Camera 1 and the 1st monitor is selected, start the process from the MENU As shown above: 1.
  • Page 19: Recalling Preset Position

    Recalling Preset Position To recall presets as follows: MON 01 <H> 10/13/98 MON 01 <H> 10/13/98 CAM 01>CAMERA01 17 28 01 CAM 01>CAMERA01 17 28 01 < Select monitor and camera. If Fast Dome Camera is set as Camera 1 of 1st monitor, start the process as shown above: 1.
  • Page 20: Auto Touring Activate/Stop

    Auto Touring Activate/Stop When preset positions were set and the groups were selected, Auto Touring can be activated by pressing AUTO PAN key. MON 01 <H> 10/13/98 MON 01 <H> 10/13/98 CAM 01>CAMERA01 17 28 01 CAM 01>CAMERA01 17 28 01 <...
  • Page 21: Recording Alarm Video Loss Signals

    Recording Alarm Video Loss Signals 03/12 08 00 CAMERA 01 ALARM MON 01 <H> 10/13/98 CAM 01>CAMERA01 17 28 01 03/12 08 10 CAMERA 02 ALARM < 03/12 09 30 CAMERA 03 ALARM 03/12 10 00 CAMERA 12 V.LOSS 03/12 11 20 CAMERA 03 ALARM 03/12 15 00 CAMERA 23 V.LOSS 03/12 23 06 CAMERA 09 V.LOSS 03/13 06 00 CAMERA 08 ALARM...
  • Page 22: Alarm Connections

    ALARM CONNECTIONS GROUP 1 JACK ALARM POINT JACK ALARM POINT JACK ALARM POINT NO OUTPUT NC OUTPUT COMMON COM OUTPUT COMMON GROUP 2 JACK ALARM POINT JACK ALARM POINT JACK ALARM POINT LEAVE LEAVE COMMON LEAVE COMMON...
  • Page 23: Setting Switch Of Receiver

    Note: Black on top represents "ON" MLP2 (Merit LILIN Protocol 2) is the new protocol for controlling fast dome cameras. The protocol contains 7 bytes which include a check-sum byte and extra control codes. The check-sum byte, for example, can prevent RS-485 interference affecting a protocol.
  • Page 24: Specification Table

    SPECIFICATION TABLE P I H - 8 1 6 P I H - 8 3 2 P I H - 8 6 4 MODEL NO. Camera Input Video Output Alarm Port Input Alarm Port Output RS485 Control R S 4 8 5 s t a n d a r d , 9 6 0 0 b a u d Protocol 8 d a t a b i t , 1 s t o p b i t , n o p a r i t y Display Mode...
  • Page 25: Rs-232 9Pin D-Sub Connection

    RS-232 9PIN D-SUB CONNECTION PIN number PIN Asignment Received Data Transmitted Data Data Terminal Ready Signal Ground Data Set Ready Data Terminal Ready 66-816IIICSE-1...
  • Page 26 MERIT LILIN ENT. CO., LTD http://www.meritlilin.com 66-816IIICSE...

This manual is also suitable for:

Pih-864iiiPih-816iii

Table of Contents