Lighting And Start-Up Instructions - Norcold 3163 Service Manual

Table of Contents

Advertisement

Figure 8
The Lighting and Start-Up Instructions are located on
the top portion of the interior door liner.
Refer to Figure 8 for location of the operating controls.
Notice: When warm humid weather conditions are ob-
served, operate the refrigerator on either AC or
DC electric for a minimum of five (5) minutes
before attempting to follow the Start-Up Instruc-
tions for Gas operation.
AC Operation
1. Press mode selection button (C).
2. Set the thermostat (B) to the coldest (maximum)
setting. Allow to operate at maximum setting for
6 to 8 hours before setting to mid range.
DC Operation
1. Press mode selection button (D). There is no
need to set thermostat to any setting. The DC
operation is a continuous run (no thermostat
control) mode.
Gas Operation
1. Set thermostat (B) to the start setting.
2. Press mode selector button (E). Ignition spark
will be present at the burner.

Lighting and Start-Up Instructions

B
A
C
D
3. Push and hold the safety valve button (A) until
the indicator lamp (G) glows steady. Continue
to hold the safety valve button in for 15 seconds
and then release. The indicator lamp should
remain a steady glow. If the lamp turns off,
repeat this step.
Notice: On initial start-up, it may take longer for
the burner to light because of air being
purged from the gas supply line.
WARNING
Do not hold gas valve in more than 30 seconds. If the
flame is not indicated within this time, press selector
switch (F), wait 2 minutes, and retry. Continuing to hold
the gas valve in will cause gas to build up in the burner
area and can result in an explosion which can cause
property damage or severe personal injury.
1. Set thermostat to desired temperature setting.
Shut-Down: All Modes
Press mode selector button (F). This will interrupt all AC
and DC power and stop operation of the refrigerator.