Download Print this page

Compass G1000i User Manual

Inverter generator

Advertisement

Quick Links

G1000i Inverter Generator
User's manual
Please read the manual carefully before using the generator.
This guide contains important guidance for safe operation.

Advertisement

loading
Need help?

Need help?

Do you have a question about the G1000i and is the answer not in the manual?

Questions and answers

Summary of Contents for Compass G1000i

  • Page 1 G1000i Inverter Generator User’s manual Please read the manual carefully before using the generator. This guide contains important guidance for safe operation.
  • Page 2 Warning As long as you operate according to the guide, the G1000i generator will be safe and reliable. Please read and understand the guide without fail before you use it, or else casualties or damage of the equipment will be caused by incorrect operation.
  • Page 3 G1000i Inverter Generator Catalogue Safety matters Label position of safety matters Components identifier Check before operation Start the engine (operation at high altitudes) Usage Turn off the engine maintenance Transport/storage Examine and repair the breakdown 10. Technical specification 11. Wiring diagram...
  • Page 4 To ensure safe operation matters Warning If you operate the G1000i generator according to the guide, the generator will run safely. Please read and understand the guide without fail before you use it, or else casualties or damage of the equipment will be caused by incorrect operation.
  • Page 5 These labels warn you of those latent dangers that will possibly cause serious accidents involving casualties. Please read carefully the words on the labels, the safety warnings and the notes recounted in the guide. If the labels have fallen off or are illegible, please contact the G1000i agent and change them.
  • Page 6 G1000i Inverter Generator Components identifier...
  • Page 7 G1000i Inverter Generator Controlling panel: Attention: Tip: We have a smart display: when the machine is running it the state of voltage, frequency, and power used by the machine. It can be useful to avoid overloading when using the machine.
  • Page 8 G1000i Inverter Generator Warning When the electrical equipment needs disconnecting from the electric power, the intelligent gasoline-saving system can not run effectively. When the generator is connected with a high electric charge, turn off the intelligent gasoline-saving valve to minimize the change of middle pressure.
  • Page 9 G1000i Inverter Generator 4. Check before operation Warning Check the generator, keep it on a horizontal surface without fail, and ensure that the engine is turned off. 1. Check the oil level Warning Using oil without cleanser or 2-strokes engine’s oil may shorten the generator’s service life.
  • Page 10 G1000i Inverter Generator the security line. But to avoid the inconvenience caused by unexpected machine halt, we advise you to check the oil level regularly. 2. Check the gasoline level: Please use gasoline for cars. (It’s better to use no lead gasoline or having low content of lead, in order to reduce the accumulation of charcoal in the burning room.)
  • Page 11 G1000i Inverter Generator The gasoline containing alcohol If you decide to use the gasoline containing alcohol (bioethanol), its octane value can not below the level recommended by manufacturer. There are two kinds of alcoholic gasoline: one contains ethanol, and the other contains methanol.
  • Page 12 G1000i Inverter Generator...
  • Page 13 G1000i Inverter Generator Start the engine Before starting the engine, cut off the load from the alternating current socket on the engine. Totally turn the valve to the “OPEN” position clockwise. Note: when transporting the engine, you should turn the ventilating pole of the gasoline-burning lid to the “CLOSE”...
  • Page 14 G1000i Inverter Generator Note: when the engine is hot or the environmental temperature is relatively high, do not use the air-blocking valve. Pull the starting hold (fig. A) slightly until you feel the pressure, then release the hold slowly by hand.
  • Page 15 G1000i Inverter Generator Attention If the engine can not restart after halting, check the oil level ahead of other failures. Operation at high altitudes At high altitudes, the standard carburetor air and gasoline mixture will become excessively dense, causing the decrease of the engine’s functions, and increase of gasoline consumption.
  • Page 16 G1000i Inverter Generator Usage of the engine If all the installations that are connected have been earthed, make sure to earth the engine. Warning In order to prevent getting an electric shock because of incorrect operation, the engine should be earthed. The earth port of the engine and the outside earth source are connected by a thick cable.
  • Page 17 G1000i Inverter Generator If you need to lengthen the cable, please use the soft cable with rubber cover (according to IEC245 or relevant requirements). The length requirement of the lengthened cable: 60 meters for 1.5 square millimeters one, and 100 meters for 2.5 square millimeters one. If the cable is too long, the resistance in it will become so large that the applicable electric power will decrease.
  • Page 18 G1000i Inverter Generator examine it to find out the breakdown. The outputting and overloading indicator lights If the generator is in a good working order, the outputting indicator light (green) is on. If the generator overloads ( over 2KVA), or in case of a short circuit inside the electrical machine it links to, the outputting indicator light (green) will turn off, while the overloading indicator light (red) will lighten.
  • Page 19 G1000i Inverter Generator Warning In order to prevent spark appearing around the battery, first link the charging wire to the generator, and then to the battery. The dismantlement should start from the battery. Before you link the charging wire to the battery which is installed on the car, first disconnect the battery’s ground wire.
  • Page 20 G1000i Inverter Generator current. Overloading direct circuit may make the defender of the direct current trip. (The pressed switch springs back.) If this happens, wait for a few minutes, and then press the defender again to re-operate. Low oil level alarming system Low oil pressure alarming system is designed to prevent the engine being damaged by lack of machine oil in the crankcase.
  • Page 21 G1000i Inverter Generator 7. Turn off the engine If you want to stop the engine urgently, turn the switch of the engine to the “CLOSE” position. Normal use: Turn off all the installations that are connected, and unplug the plug (Fig. B).
  • Page 22 G1000i Inverter Generator 8. Maintenance The purpose of making maintenance and adjustment plan is to keep the generator in the best working condition. Please check and maintain the generator according to the plan in the following chart. Warning Please turn off the engine before you carry out any repair. If the engine needs to run when repairing, make sure the operating area is well ventilated, as the exhaust contains toxic CO.
  • Page 23 G1000i Inverter Generator (1). If used in dirty places, the generator should be maintained more regularly. (2). Unless the user has proper tool or he is a specialist on machine, the maintenance of the above items should be done by the authorized agent. Please refer to the handbook.
  • Page 24 G1000i Inverter Generator send it to the local repair station or recycle center. Do not pour the oil to the ground or into the rubbish. 3. Maintenance of the air filter Dirty air filter will block the air from entering the carburetor. In order to prevent the carburetor from failure, please maintain the air filter regularly.
  • Page 25 G1000i Inverter Generator 3. Maintenance of the spark plug Recommended spark plug: A7RC or NGK R7HSA To ensure the engine to work in good order, the clearance of the spark plug must be correct, and has no accumulated charcoal. 1. Dismantle the repair cover of the spark plug (Fig. A).
  • Page 26 G1000i Inverter Generator 7. Install the spark plug carefully by hand. Pay attention not to overlap the screw thread. 8. After installing a new spark plug by hand, screw it with a spanner for a half circle in order to press the washer tightly. If an old spark plug is installed, you only need to screw it from one eighth circle to one fourth circle after it is fixed.
  • Page 27 G1000i Inverter Generator 9. Transport / Storage In order to avoid the generator leaking oil during transport or temporary storage, make sure to switch off the generator, keeping it at a standing pose under normal operations. After the engine is totally cooled, turn the ventilating pole of the gasoline-filling lid to the “close”...
  • Page 28 G1000i Inverter Generator C. Screw down the oil-discharging screw on the lid of the spark plug. Pull the starting hold for three or four times, and discharge the gasoline from the oil-spouting pump. D. Turn the switch of the engine to the “CLOSE” position. Then screw the oil-discharging screw tightly.
  • Page 29 G1000i Inverter Generator 10. Examine and repair the breakdown If the engine can not be started: Does the gasoline tank still have gasoline? → If not, fill gasoline into the gasoline tank. ↓yes Is the switch of the generator on the “open” position?→ If not, switch on the engine.
  • Page 30 G1000i Inverter Generator 11. Technical specifications Size and weight model G1000I length*width*height(mm) 480*260*380 net weight(kg) 15.3 Engine model 144F engine type stroke 4, overhead air valve, one cylinder exhaust quantity(diameter of tank * stroke) 43,5*36mm compressing proportion 8.5:1 rotate speed...
  • Page 31 G1000i Inverter Generator...