Advertisement

Quick Links

Climax Air Inc.
DC Inverter Portable Air Conditioner
Model VS12 12,000 BTU
Introducing The World's
Most Efficient Portable Air Conditioner
VS12 User & Installation Manual Version 1.0
1
Climax Air Inc.
www.climax-air.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VS12 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Climax VS12

  • Page 1 Climax Air Inc. DC Inverter Portable Air Conditioner Model VS12 12,000 BTU Introducing The World’s Most Efficient Portable Air Conditioner VS12 User & Installation Manual Version 1.0 Climax Air Inc. www.climax-air.com...
  • Page 2 • The appliance, if it includes an electric heater, shall have at least 3 feet of clearance to combustible materials. • Contact an authorized service technician for repair or maintenance of this unit. • Contact an authorized installer for installation of this unit. Climax Air Inc. www.climax-air.com...
  • Page 3: Table Of Contents

    Operating instructions……………………………………………………………………………………………….. 9 INSTALLATION INSTRUCTIONS Location…………………………………………………………………………………………………………………….. 11 Window kit installation……………………………………………………………………………………………… 11 Exhaust hose installation…………………………………………………………………………………………… 14 Water drainage…………………………………………………………………………………………………………. 15 CARE AND MAINTENANCE Care and maintenance………………………………………………………………………………………………. 16 TROUBLESHOOTING TIPS Trouble shooting……………………………………………………………………………………………………..… 17 REMOTE CONTROL Remote Control ……………………………………………………………………………………………………..… 18 Climax Air Inc. www.climax-air.com...
  • Page 4: Environmental Notes

    • Children should be supervised to ensure that they do not play with the appliance. Climax Air Inc. www.climax-air.com...
  • Page 5: Safety Precautions Safety Rules

    1. Screwdriver 2. Tape measure or ruler 3. Knife or scissors 4. Saw (in the event that the window kit needs to be cut down in size because the window is too narrow for a direct installation) Climax Air Inc. www.climax-air.com...
  • Page 6: Electrical Information

    • Check that all the accessories are included within the package and please refer to the installation instructions for their usage. NOTE: All the illustrations in this manual are for explanative purpose only. Your air conditioner may be slightly different. The actual shape shall prevail. Climax Air Inc. www.climax-air.com...
  • Page 7: Names Of Parts

    ❽ Drain outlet ❾ Power cord outlet ❿ Power cord buckle (used only when storing the unit) Bottom tray drain outlet Power plug socket (use only when storing the unit) Vent control Air inlet Air filter Drain outlet Climax Air Inc. www.climax-air.com...
  • Page 8: Air Conditioner Features

    Celsius. To convert from one to the other, press ❽ LED Display and hold the Up and Down buttons at the same Shows the set time, for 3 seconds. and the While on DRY and FAN the room Climax Air Inc. www.climax-air.com...
  • Page 9: Operating Instructions

    0.0 will cancel the dehumidifying effect. Auto Start/Stop timer program. - Do not put the duct in the window. - When a malfunction (E1, E2, E3 or E4) occurs, the Auto Start/Stop timed program will also be cancelled. Climax Air Inc. www.climax-air.com...
  • Page 10 - When the Power is ON, the louver opens fully. Press the SWING button on the panel or remote controller to initiate the Auto swing feature. - The louver will swing up and down automatically. - Please do not try to adjust the louver manually. Climax Air Inc. www.climax-air.com...
  • Page 11: Installation Instructions Location

    Note: If the window opening is less than the mentioned minimum length of the window slider kit, cut the one with the hole in it short to fit the window opening. Do never cut out the hole in window slider kit. Climax Air Inc. www.climax-air.com...
  • Page 12 4. Close the window sash securely against the window. 5. Cut the foam seal to an appropriate length and seal the open gap between the top window sash and outer window sash. As shown in Fig. 11. Climax Air Inc. www.climax-air.com...
  • Page 13 Shown as in Fig.15. NOTE: All the illustrations in this manual are for explanation purpose only. Your unit may be slightly different. The actual shape shall prevail. Climax Air Inc. www.climax-air.com...
  • Page 14: Window Kit Installation

    The OPEN position removes stale air from the room and exhausts it to the outside. Fresh air is drawn in through normal passages in the home. When you don’t need to circulate the room air, set the Vent Control to the CLOSED position. Climax Air Inc. www.climax-air.com...
  • Page 15: Water Drainage

    (Fig.22). Reinstall the bottom drain plug and restart the machine until the "P1" symbol disappears. If the error repeats, call for service. NOTE: Be sure to reinstall the bottom drain plug before using the unit. Climax Air Inc. www.climax-air.com...
  • Page 16: Care And Maintenance

    - Stop the appliance and unplug it, wrap the cord and bundle it with tape(Fig.25). Remove the batteries from the remote controller. - Clean the air filter and reinstall it. Climax Air Inc. www.climax-air.com...
  • Page 17: Troubleshooting Tips

    5. Gurgling sound of the refrigerant inside the air- It is normal. conditioner. The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agent or manufacturer for details. Climax Air Inc. www.climax-air.com...
  • Page 18: Remote Controller Illustration

    AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION Climax Air Inc. www.climax-air.com...
  • Page 19 CONTENTS Handling the remote controller……………………………………………………………………………………………………. 2 Remote controller Specifications……………………………………………............3 Function buttons…………………………………………………………………………………………………………………………...4 Indicators on LCD……………………………………………………………………………………………………………………………6 How to use the buttons……………………………………………………………………………………………………………..7 Auto operation………………………………………………………………………………………………………………………………..7 Cooling/ Fan operation……………………………………………………………………………………………………….7 Dehumidifying operation…………………………………………………………………………………………………………………8 Swing operation………………………………………………………………………………………………………………………………8 Timer operation………………………………………………………………………………………………………………………………9 ECONOMY operation……………………………………………………………………………………………………………………..12 Climax Air Inc. www.climax-air.com...
  • Page 20: Handling The Remote Controller

    Batteries, placing the ( + ) and ( - ) ends correctly. (3) Reattach the cover by sliding it back into position. NOTE: When the batteries are removed, the remote controller erases all programming. After inserting new batteries, the remote controller must be reprogrammed. Climax Air Inc. www.climax-air.com...
  • Page 21: Remote Controller Specifications

    3. Indoor Setting Temperature Range: 17°C~30°C (62°F~88°F). 4. Full function of LCD (Liquid Crystal Display). NOTE: All the illustrations in this manual are for explanation purpose only. Your air conditioner may be slightly different. The actual shape shall Prevail. Climax Air Inc. www.climax-air.com...
  • Page 22 Once the recessed RESET button is pressed, all of the current settings will be cancelled and the controller will return to the initial settings. You must press the “ON” button on the remote to reactivate the remote. Climax Air Inc. www.climax-air.com...
  • Page 23 TIMER ON/OFF which indicates you have chosen both the Auto-on time and Auto-off time. LOCK Indicator LOCK display is displayed when pushing the LOCK button. Push the LOCK button to clear display. Climax Air Inc. www.climax-air.com...
  • Page 24: How To Use The Buttons

    You are not able to control the room temperature either. In this case, only step 1, 3 and 4 may be performed. Climax Air Inc. www.climax-air.com...
  • Page 25: Dehumidifying Operation

    To set the louver to a desired position, press the button once to move the louver to its position the press the button again to stop it. Climax Air Inc. www.climax-air.com...
  • Page 26: Timer Operation

    Then, after approximately another 2 seconds, the signal “h” will disappear and the set temperature will re-appear on the LCD display window. Climax Air Inc. www.climax-air.com...
  • Page 27 2. Press the TIMER ON button to display “6:0h” on the TIMER ON display of the remote controller. 3. Wait for about 3 seconds and the digital display area will show the temperature against. Now this function is activated. Climax Air Inc. www.climax-air.com...
  • Page 28 2.0h on the TIMER OFF display. 3. Press the TIMER ON button. 4. Press the TIMER ON button again to display 10h on the TIMER ON display. 5. Wait for the remote control to display the setting temperature. Climax Air Inc. www.climax-air.com...
  • Page 29 AUTO mode only. For the details, see “Sleep operation” in the “USER’S MANUAL”. NOTE: While the unit is running under SLEEP mode, it would be cancelled if the MODE, FAN SPEED or ON/OFF button is pressed. Climax Air Inc. www.climax-air.com...
  • Page 30 • Connect the equipment into an outlet on a circuit different form that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment. Climax Air Inc. www.climax-air.com...