Electrical Adjustments; Preparations; Required Equipment; Service Mode Setting - Sony VPL-VW90ES Service Manual

Hide thumbs Also See for VPL-VW90ES:
Table of Contents

Advertisement

2-1. Preparations

2-1-1. Required Equipment

. Oscilloscope
Tektronix 2465 or equivalent (bandwidth: 350 MHz or more)
. NTSC, PAL, SECAM component signal generator
Tektronix TG2000 +AVG1 (optional module) +AWVG1 (optional module) or equivalent
. VG (Programmable video signal generator)
VG849C or equivalent
. Digital voltmeter
Advantest TR6845 or equivalent
. Luminance meter
. Chrominance difference gauge
n
Perform the following adjustments at least 15 minutes after turning on the power.

2-1-2. Service Mode Setting

1. Set the "Status" to "On" in the "Setup" menu.
2. Close the menu by pressing "MENU" if its displayed.
3. Press the buttons in the following order in 5 seconds: " "→" "→" "→" "
4. The message "Do you wish to enter into the SERVICE MODE? Yes No" will be displayed.
5. Select "Yes".
m
. When leaving the SERVICE MODE, perform step 3.
"Do you wish to return to the USER MODE? Yes No" will be displayed. Select "Yes".
. Before entering or exiting the SERVICE MODE, be sure to select any input terminals other than
HDMI1 and HDMI2. Alternately, select the menus in the following order: MENU/Function/Control for
HDMI Setting/Control for HDMI, and change the setup from ON to OFF.
. Note that when the items (W/B, Device Adjust) that can be adjusted in the Service mode are adjusted
and stored in memory, they are saved in NVM and the factory default data will be lost.
Be sure to perform "Save to memory" after entering and exiting the Gamma adjustment mode. If the
values are changed in the Gamma adjustment mode and you want to reset to the original value, turn off
the power of the unit and turn it on again. The UF data does not change even if the mode for Advanced
Iris in Cinema Black Pro in Picture Adjust is changed without performing "Save to memory". When
"Save to memory" is performed at that time, the UF data of each Iris mode will be overwritten and lost.
VPL-VW90ES
Section 2

Electrical Adjustments

2-1 (E)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents