Troubleshooting - Philips 32PFL4508 Service Manual

Hide thumbs Also See for 32PFL4508:
Table of Contents

Advertisement

[Power Supply Section]
FLOW CHART NO.1
The power cannot be turned on.
Is the fuse (F602) normal?
Is the P-ON+21V line voltage normal?
FLOW CHART NO.2
The fuse blows out.
FLOW CHART NO.3
When the output voltage fluctuates.
FLOW CHART NO.4
When buzz sound can be heard in the periphery of power circuit.

TROUBLESHOOTING

Yes
Yes
Yes
Yes
No
See FLOW CHART No.2 <The fuse blows out.>
No
Check if there is any leak or short-circuit on the
primary circuit component and repair it if defective.
(D601, D602, D603, D604, Q601, Q602, T601)
No
No
Check IC602, D660, D661, Q653 and their periphery
circuit. Repair it if defective.