Smalvic AI-45BT LX12-ETCR INOX Use And Maintenance Manual

Blast chillers - quick freezers

Advertisement

Quick Links

USE AND MAINTENANCE MANUAL FOR BLAST CHILLERS - - - -
USE AND MAINTENANCE MANUAL FOR BLAST CHILLERS
USE AND MAINTENANCE MANUAL FOR BLAST CHILLERS
USE AND MAINTENANCE MANUAL FOR BLAST CHILLERS
AI-45BT LX12-ETCR INOX / AI-45BT LX12-ETCW INOX
AI-45BT LX12-TCR INOX / AI-45BT LX12-TCW INOX
9880028100-EN-240314
QUICK FREEZERS
QUICK FREEZERS
QUICK FREEZERS
QUICK FREEZERS
MODELS:
MODELS:
MODELS:
MODELS:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AI-45BT LX12-ETCR INOX and is the answer not in the manual?

Questions and answers

Summary of Contents for Smalvic AI-45BT LX12-ETCR INOX

  • Page 1 USE AND MAINTENANCE MANUAL FOR BLAST CHILLERS USE AND MAINTENANCE MANUAL FOR BLAST CHILLERS - - - - QUICK FREEZERS QUICK FREEZERS QUICK FREEZERS QUICK FREEZERS MODELS: MODELS: MODELS: MODELS: AI-45BT LX12-ETCR INOX / AI-45BT LX12-ETCW INOX AI-45BT LX12-TCR INOX / AI-45BT LX12-TCW INOX 9880028100-EN-240314...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS PAGE GENERAL WARNINGS BLAST CHILLER FEATURES SAFETY MEASURES - IMPORTANT INFORMATION UNPACKING DISPOSAL OF THE MACHINE INSTALLATION DIMENSIONS CABINET INSERTING THE BLAST CHILLER IN THE CABINET FEATURES OF THE CABINET ELECTRICAL CONNECTION ASSEMBLY/REPLACEMENT OF THE POWER SUPPLY CABLE DESCRIPTION OF CONTROL PANELS AND DISPLAY...
  • Page 3: General Warnings

    GENERAL WARNINGS BLAST CHILLER FEATURES This manual contains the instructions for the installation, use and maintenance of the blast chiller and must always be kept with the unit, even when changing owners. Before operating, read the instructions thoroughly to prevent any risks to people or property. This will also lead to optimal operation of the unit with maximum performance.
  • Page 4: Unpacking

    UNPACKING Remove the cardboard and Styrofoam packaging, lift out the unit and remove the wooden platform. Place the unit on the ground near the area where it is to be installed. Check the integrity of the machine and make sure it was not damaged during transport.
  • Page 5: Dimensions

    DIMENSIONS CABINET The dimensions of the opening to be made in the cabinet for fitting the blast chiller are indicated in the figures. Make sure the cabinet in which the blast chiller will be installed is able to support the weight of 40 kg. It is necessary to create an opening in the rear part of the bottom of the cabinet or in the blast chiller support shelf, to allow sufficient air entry and circulation for proper operation.
  • Page 6: Inserting The Blast Chiller In The Cabinet

    INSERTING THE BLAST CHILLER IN THE CABINET It is important that all operations relating to installation of the device are carried out by qualified staff. Ensure the blast chiller is safely installed inside the cabinet. Use screws A for mounting the blast chiller. FEATURES OF THE CABINET The technical requisites of the cabinet are the following: The cabinet and its components must be able to withstand temperatures of up to 90°C without presenting...
  • Page 7: Description Of Control Panels And Display

    TWO KNOB ASSISTED TOUCH CONTROL PANEL ON/OFF key FISH SANIFICATION CYCLE key PRECOOLING CYCLE key BOTTLE CHILLING CYCLE key START/STOP key CONFIRM key UP/DOWN SELECTION knob +/- SELECTION knob CONFIRM by pressing CONFIRM by pressing MODELS: AI-45BT LX12-ETCR INOX AI-45BT LX12-ETCW INOX 9880028100-EN-240314...
  • Page 8: Shared Display

    SHARED DISPLAY TIME display CLOCK display TEMPERATURE display OPERATION display TIMER icon ALARM icon PROGRESSIVE TIME icon CYCLE DURATION icon BLAST CHILLING icon DEEP FREEZING icon BLAST CHILLING +3° C icon DEEP FREEZING -18° C icon HARD icon NEEDLE PROBE icon DEFROST icon PRECOOLING icon BOTTLE icon...
  • Page 9: Activation And Shutdown (On/Off)

    If a blackout - power failure occurs during a blast chilling/deep freezing or storage cycle, when reset the unit will start the cycle from where it was interrupted and will indicate it using an intermittent audible signal for 3 minutes or until a key is pressed.
  • Page 10 For: Soups, broths, roast beef, barbecued meat, Béchamel POSITIVE +3° C TIMED HARD BLAST CHILL CYCLE (80 MINUTES) For: Pork roast, meat loaf, beans, potato salad POSITIVE +3° C TIMED HARD BLAST CHILL CYCLE (90 MINUTES) For: Meat sauce, roasted meat, braised meat, stewed meat -18°...
  • Page 11: Selecting Saved Programs

    POSITIVE +3° C SOFT BLAST CHILL CYCLE WITH NEEDLE PROBE Default Default Set Temp. Chamber -2°C -10°C 0°C Set Probe Temp. 3°C 0°C 10°C POSITIVE +3° C HARD BLAST CHILL CYCLE WITH NEEDLE PROBE Default Default Set Chamber Temp. -3°C -10°C 0°C Set Probe Temp.
  • Page 12: Changing Settings In An Editable Program

    Before starting the cycle, read the instructions described in the chapter OPTIMISING THE WORK CYCLES. After selecting the program desired, press the key to start the cycle. The rapidly alternating icons and the flashing icon indicate that the cycle is in operation. At the end of the cycle, the unit will emit an audible signal for 3 minutes and will automatically go into the STORAGE cycle indicated by the icon, the word...
  • Page 13: Description Of Special Cycles

    DESCRIPTION OF SPECIAL CYCLES BOTTLE CHILLING CYCLE The BOTTLE CHILLING CYCLE allows the user to quickly chill bottles of wine, beer or any other beverage. The unit allows the operating time for this cycle to be varied. Once the program is selected, turn the knob until you see the flashing icon .
  • Page 14: Display Description

    DISPLAY DESCRIPTION DISPLAY ELAPSED TIME The unit lets you display the elapsed time of the cycle in progress. When the knob (in the versions with knobs) or the key (in the versions without knobs) is pressed, the display and the icon flash, displaying the elapsed time (for 5 seconds).
  • Page 15: Parameters That Can Be Changed By The User

    PARAMETERS THAT CAN BE CHANGED BY THE USER The unit lets the user change the volume values and brightness of the display. The parameters are accessed with the unit off by simultaneously pressing the keys (in versions with knobs) or the keys (in versions without knobs), for at least 3 seconds.
  • Page 16: Ordinary Maintenance

    ORDINARY MAINTENANCE WARNINGS Read the safety precautions and warnings in the beginning of the manual. The manufacturer shall not be liable for any damages caused by incorrect operations or any improper use of the machine according to what is specified in this instruction manual. It is essential to remember some basic operations before cleaning: Disconnect the machine from the mains by turning of the main switch and unplugging.
  • Page 17: Troubleshooting

    TROUBLESHOOTING The following table is a valid and useful support in seeking possible solutions to some operating anomalies that could occur. PROBLEM CAUSE SOLUTION The controller / board does Check the power and make sure the unit is No power not come on plugged in.
  • Page 18: Wiring Diagram

    WIRING DIAGRAM 9880028100-EN-240314...