  • Page 1: Wood Burning

    FIREWARM 8, 12, 20, Maxi FREESTANDING WOOD BURNING BOILER STOVES Installation and Operating Instructions Please hand these instructions to the stove user when the installation is complete. Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls.
  • Page 2: Technical Specifications

    Technical Specifications. Main Dimensions Firewarm 8 6” 1” Firewarm 12 6” 1.5” 6” 1.5” Firewarm 20 Firewarm Maxi 6” 1.5” Technical Specifications (Wood) Firewarm 8kW Firewarm 12kW Firewarm 20kW Firewarm Maxi Boiler Boiler Boiler Boiler Total Heat Output 13.0 20.9 27.1...
  • Page 3: Assembly Instructions

    It is strongly recommended that this stove is fitted to your heating system by a knowledgeable, experienced and suitably qualified (Hetas or equivalent) plumber or Heating Engineer with experience in fitting boiler stoves. Firewarm Stoves cannot accept responsibility for any fault arising through incorrect installation.
  • Page 4 1. Remove stove from pallet and carefully tip it over onto it’s back. 2. Ensure legs and fixings are present as shown. 3. Ensure the tapped holes, on the base, are free from obstruction. Use a sharp screwdriver to remove any fire cement. Secure the legs and fixings using the screws and washers provided, two screws and two washers per leg.
  • Page 5 1. Fit the Flue Collar using the 4-M6 set screws and washers supplied. Screw The M6 nuts on the M6 screws all the way to the end. Then put the washer over the screw/nut assembly and secure the collar to the lid/back as desired. The flue collar is shown below fixed to the top of the stove.
  • Page 6 List of Components Door Handle Airwash Control Handle Airwash assembly Primary Air Caps Riddling Handle Ash Pan Ash Pan Tool Coal Catcher Baffle Plate Legs Leg Height Screws M8 Leg Screws M8 Leg Washers M8 Flue Collar Flue Collar Screws M6 Flue Collar Nuts M6 Flue Collar Washers M6 Grate Surround LH...
  • Page 7: Installation Instructions

    Installation Instructions READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION These instructions cover the basic principles to ensure satisfactory installation of the stove, although detail may need slight modification to suit particular local site conditions. In all cases the installation must comply with National and European Building Regulations, Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove.
  • Page 8 these requirements are not met, the chimney should be lined by a suitable method. The chimney must be swept before connection to the stove. Where the chimney is believed to have previously served an open fire installation, it is possible that the higher flue gas temperature from the stove may loosen deposits that were previously firmly adhered, with the consequent risk of flue blockage.
  • Page 9 Boiler Connection Revised 11-07-11...
  • Page 10 The gravity circuit must not contain any shut off valves and should be fully lagged to minimise heat loss. The pipes should not exceed 7.8 meters (25ft) in length to/from the cylinder. In general, the shorter the run of pipework the less heat loss and the more efficient the water heating.
  • Page 11 A heat soak radiator of at least 2kW must be used on the same gravity circuit, positioned above the stove. This is used to dissipate heat when the central heating is switched off or the HW cylinder is fully heated. Link Up: On heating and hot water installations, a semi-pumped system should be used to the central heating system with gravity circulation to the hot water cylinder.
  • Page 12: Operating Instructions

    Operating Instructions This appliance is not suitable for use in a shared flue. This appliance should not be operated with the doors open. Aerosol Sprays Do not use an aerosol spray on or near the stove when it is alight. Air Controls This stove has been designed to burn clean and efficient.
  • Page 13 Do not use liquid fuels in this appliance. Size of Fuel Log Length Maximum Log Lengths Firewarm 8 Boiler Stove 350mm Firewarm 12 Boiler Stove 390mm Firewarm 20 Boiler Stove...
  • Page 14 Lighting the Stove We recommend that you have two or three small fires before you operate your stove to its maximum heat output. This is to allow the paint to cure in steadily and to give a long service life of the paint finish.
  • Page 15: Safety Notes For Your Guidance

    Safety Notes for your guidance FIRES CAN BE DANGEROUS – Always use a fireguard in the presence of children, the elderly or the infirm. DO NOT OVERFIRE – it is possible to fire the stove beyond its design capacity, this could damage the stove, so watch for signs of overfiring –...
  • Page 16 Each stove will have spin valves, which will allow you to easily regulate the heat output. 5 What warranty policy do I get? Firewarm Stoves will replace, free of charge, any working part that fails (under normal operating conditions) within 12 months of purchase. Consumables such as glass or stove rope are not guaranteed.