•When the STOP button is pressed while the TEST-PLAY menu appears, or in TEST-PLAY or continuous playback mode, the mode changes
to the TEST mode stop state.
• When the PLAY button is pressed while the TEST-PLAY menu appears,continuous playback is initiated from the current pickup position.
• Whenever the DISP button is pressed in the TEST-PLAY mode, the address changes as follows.
0050 — 03C0 — 0700 — 08A0 — 0050 —
• Whenever the BASS key is pressed in the TEST-PLAY mode, the digit which is changed by the SKIP UP/DOWN button changes as follows.
0050 — 0050 — 0050 — 0050 — 0050 —
• When the SKIP UP button is pressed in the TEST-PLAY mode, the digit of address specified by the BASS button is set to +1h. (0 to F)
• When the SKIP DOWN button is pressed in the TEST-PLAY mode, the digit of address specified by the BASS button is set to -1h. (0 to F)
* When the SKIP UP/DOWN button is held down, the setting changes continuously, one cycle being 100 ms.
• When the BASS button is pressed in the continuous playback mode, the number of jump lines changes as follows.
1 — 10 — 400 — 1
* After the number of jump lines is indicated for one second, the address indication is restored.
• When the SKIP UP button is pressed in the continuous playback mode, the specified number of lines is jumped in the FWD direction.
• When the SKIP DOWN button is pressed in the continuous playback mode, the specified number of lines is jumped in the REV direction.
* When the SKIP UP/DOWN button is held down, jump is repeated every approx. 100 ms.
•Whenever the DISP button is pressed in the continuous playback mode, the indication changes as follows.
* Pit section
Continuous playback (SUBQ address indication)
[ S Q
|
Continuous playback (C1 error indication)
[ C E
|
Continuous playback (SUBQ address indication)
[ S Q
* Groove section
Continuous playback (ADIP address indication)
[ A P
|
Continuous playback (C1 error indication)
[ C E
|
Continuous playback (ADIP error indication)
[ A E
|
Continuous playback (ADIP address indication)
[ A P
: Address
: C1 Error rate
: ADIP Error rate
: JUMP lines
Mechanism Adjustment
1. Optical pickup grating inspecting method
OSCILLOSCOPE
TP141
GND
100Kohm
TP132
EOUT
470p
GND CH1 CH2
470p
b
X
Y
TP133
FOUT
100Kohm
LISSAJOUS'S WAVEFORM
LESS THAN A:B = 3:1
Figure 12-1 OPTICAL PICKUP GRATING DEVIATION
MEASURING METHOD
After the automatic adjustment is performed in the AUTO mode
(test mode) with the aid of high refection MD disc ("COMPLATE" is
displayed), the Lissajous's waveform (x-y) is adjusted.
1. Slightly loosen the 3 screws of spin motor, and make an
adjustment, observing the Lissajous's wavefor.
2. After adjustment tighten the screws in arder of<1> , <2> ,< 3> .
3. It confirms Lissajous's wavwform ripple mark once again.
[
T R _ ]
]
]
]
]
]
]
]
a
2
1
Shifting the spin motor installation
position, check the Lissajous's
waveform.
Figure 12-2
5. TEST-REC Mode
Step No.
Step 1
Test mode STOP state
Step 2
BASS button
Step 3
AUTO menu
Step 4
SKIP UP button x 4times (Or SKIP DOWN button x 6 times)
Step 5
TEST-REC menu
Step 6
When the DISP button is pressed, the process proceeds to (7).
When the PLAY button is pressed, the process proceeds to (9).
Step 7
TEST-REC mode
Step 8
PLAY button
Step 9
Continuous playback mode (groove)
Step 10
STOP button
Step 11
Test mode STOP state
• When the STOP button is pressed while the TEST-REC menu appears, or in the TEST-REC mode or continuous record mode, the mode
changes to the TEST mode stop state.
• When the PLAY button is pressed while the TEST-REC menu appears, the continuous record is initiated from the current pickup position.
• Whenever the DISP button is pressed in the TEST-REC mode, the address changes as follows.
0050 — 03C0 — 0700 — 08A0 — 0050 —
• Whenever the BASS button is pressed in the TEST-REC mode, the digit which is changed by the SKIP UP/DOWN button changes as
follows.
0050 — 0050 — 0050 — 0050 — 0050 —
• When the SKIP UP button s pressed in the TEST-REC mode, the digit of address specified by the BASS button is set to +1h.(0 to F)
• When the SKIP DOWN button is pressed in the TEST-REC mode, the digit of address specified by the BASS button is set to -1h. (0 to F)
* When the SKIP UP/DOWN button is held down, the setting changes continuously, one cycle being 100 ms.
• When the VOL UP/DOWN button is pressed in the TEST-REC mode or continuous record mode, the laser record power changes.
(Servo gain changes also according to record power.)
* After the laser record power is indicated for one second, the address indication is restored.
: Address
: Laser power cord
• Operation is disabled if the premastered disc or disc is in miserase-protected state.
6. INNER Mode
Step No.
Setting Method
Display
Step 1
Test mode STOP state
[
T E S T
Step 2
BASS button
Step 3
AUTO menu
[
A U T O
Step 4
SKIP UP button x 5 times
(Or SKIP DOWN button x 5 times)
Step 5
INNER menu
[
I N N E R
3
• When the STOP button is pressed while the INNER menu appears, the mode changes to TEST mode stop state.
: Address
Setting Method
[
[
[ T
[ A d 0 0 5 0
[ A P
[
[ R P W
]
Step No.
Setting Method
]
Step 6
PLAY button
Step 7
INNER switch position measurement
[ S Q
]
Step 8
STOP button
Step 9
Test mode STOP state
[
]
Display
T E S T
]
A U T O
]
R E C
]
]
]
T E S T
]
Display
]
T E S T
]

Advertisement