UWE Viper 2000 Installation Instructions Manual

UWE Viper 2000 Installation Instructions Manual

Advertisement

Quick Links

I n t r o d u c t i o n
This instruction sheet only deals with control unit Viper
2000.
Remove all packaging and check that the goods supplied
are not damaged.
Check that the articles supplied correspond with those
specified on the delivery note.
P l a c e m e n t o f t h e c o n t r o l u ni t s
The control units are to be placed at a place where it is protect-
ed from water. The nodes should be placed in the distribution
box. The display unit is to be places in a way that the driver
doesn't have to move, and preferably in a way that a minimum
of sunlight is reflected in the display.
To mount the sensors, see separate installation sheet
PRD0070.
S t r u c t u r e o f t h e c o n t r o l s y s t e m

Example of structure in an articulated bus

PRD0167E01en
Drivers place temperature
Outside temperature
Defroster temperature
Drivers place
Flap: Floor/Screen, Fresh/Recirc
Gov. valves: Defroster, Drivers convector
Fans: Heating fan, Defroster fan
Compartment temperature
Air duct temperature
Feed water temperature
Climate zone 1
Node 1
Flap: Fresh/Recirculation
Gov. valves: Convectors, TSV
Fans: Heating fan, TSV
Node 2
UWE Verken AB
Installation Instructions
Viper 2000 Control System
Read through the documentation attached to the prod-
uct before starting installation work.
Ensure that the control units are placed at a place pro-
tected from water.
Compartment temperature
Air duct temperature
Auxiliary temperature
Climate zone 2
Flap: Fresh/Recirculation
Gov. valves: Convectors, TSV
Fans: Heating fan, TSV
Booster pump (node 1 when two-axled bus)
AC system (node 1 when two-axled bus)
PRD0167E01en
1(6)

Advertisement

loading

Summary of Contents for UWE Viper 2000

  • Page 1 Installation Instructions Viper 2000 Control System PRD0167E01en I n t r o d u c t i o n • This instruction sheet only deals with control unit Viper 2000. • Remove all packaging and check that the goods supplied Read through the documentation attached to the prod- are not damaged.
  • Page 2 Installation Instructions, Viper 2000 Control System C o n n e c t i o n o f d is p l a y u n i t ( s y s t 1 ) Connections to components should be performed according to...
  • Page 3 Installation Instructions, Viper 2000 Control System Table 1: Display unit Description Comment Type footnote Relay + AC : CO2 12 pole AC Ice detection <5V = Ice CO2:1 Digital input AC HP In series with Clutch activation CO2:2 Digital input...
  • Page 4 Installation Instructions, Viper 2000 Control System C o n n e c t i o n o f c o m p a r t m e n t u ni t ( s y s t 1 ) Connections to components should be performed according to...
  • Page 5 Installation Instructions, Viper 2000 Control System Table 2: Compartment unit Description Comment Type footnote PWM - 26 kHz Duty Cycle modulated differential CO1:19 EIA RS485 transmitter out- output for direct interface with PWM switch. put. 15kV ESD protection, NonInv. slew rate limited.
  • Page 6 Installation Instructions, Viper 2000 Control System The feedback potentiometers can be connected If no high current drivers are used, only one of directly between GND and +24V. Variations of these outputs need to be used. If only one high supply voltage is internally compensated.