Metos MAXIGLASS NOVERTA User Manual
Metos MAXIGLASS NOVERTA User Manual

Metos MAXIGLASS NOVERTA User Manual

Glass door bottle coolers

Advertisement

Quick Links

GLASS DOOR BOTTLE COOLERS
METOS MAXIGLASS NOVERTA
4146700,4146702, 4146704, 4146706, 4146708, 4146710, 4146712, 4146714, 4146716, 4146718, 4146720, 4146722, 4146724,
4146726, 4146728, 4146730, 4146732, 4146734

USER MANUAL

05.10.2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAXIGLASS NOVERTA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Metos MAXIGLASS NOVERTA

  • Page 1: User Manual

    GLASS DOOR BOTTLE COOLERS METOS MAXIGLASS NOVERTA 4146700,4146702, 4146704, 4146706, 4146708, 4146710, 4146712, 4146714, 4146716, 4146718, 4146720, 4146722, 4146724, 4146726, 4146728, 4146730, 4146732, 4146734 USER MANUAL 05.10.2012...
  • Page 2: Table Of Contents

    Table of Contents Safety precautions ............................3 1.1. Refrigerant ..............................3 1.2. During operation ............................3 1.3. After use ..............................3 Product description ..........................4 2.1. Type plate ..............................4 Installation ..............................5 3.1. How does it work ............................5 3.2. Installing the appliance ..........................5 3.3. Fitting storage racks ............................5 3.4.
  • Page 3: Safety Precautions

    METOS Maxiglass Noverta 05.10.2012 Safety precautions Prior to use check • whether the power supply is suitable for this product • that the plug and the lead are not damaged • ensure that the product is standing fi rmly and level Hold the plug when removing the plug from the socket.
  • Page 4: Product Description

    05.10.2012 METOS Maxiglass Noverta Product description 1 Type plate (inside) 3 Air in/outlet 5 Thermostat 2 Door 4 On/off switch 2.1. Type plate Type Refrigerant type + volume Power consumption Supply Rated current Climate classifi cation * Construction year Unit serial number *A refrigerator is produced for optimal performance within certain ambient temperatures.
  • Page 5: Installation

    METOS Maxiglass Noverta 05.10.2012 Installation Never install the refrigerator next to a heat source. 3.1. How does it work A refrigerator works by extracting heat from the space to be refrigerated and to release this in the sur- rounding area. For maximum air circulation it is recommended to allow at least 10 cm space around the refrigerator.
  • Page 6: Power Supply

    05.10.2012 METOS Maxiglass Noverta 3.4. Power supply • If this device cable is damaged it must be replaced with an original cable supplied by the producer. • In case of emergency: remove the plug lead from the socket. • The socket should be within easy reach of the cabinet.
  • Page 7: Using The Appliance

    METOS Maxiglass Noverta 05.10.2012 Using the appliance 4.1. Prior to use • Clean the cabinet prior to use. For further details we refer to the maintenance section. • Leave the installation to stand for at least 2 hours before switching on the cabinet.
  • Page 8: Temperature Setting

    05.10.2012 METOS Maxiglass Noverta 4.2.1. Temperature setting • Push and immediately release the SET key, the set point will be shown. • Push and relase of SET key or wait for 5 sec. to return to the normal view. Change of setpoint •...
  • Page 9: Alarm Signals

    METOS Maxiglass Noverta 05.10.2012 4.2.5. Alarm signals Mess. Cause Output Room probe failure Compressor output according to Con e COF Evaporator probe failure Defrost end is timed Condenser probe failure Condenser temperature alarm is not managed Maximum temperature alarm Outputs unchanged...
  • Page 10: Cleaning

    05.10.2012 METOS Maxiglass Noverta Cleaning • Before fi rst use the cabinet should be cleaned using water and a mild detergent. • Intensive use requires regular cleaning. • The MG1/** has a maintenance free condenser. • Check and clean the magnetic seals on a regular basis. If the seal is not airtight it will have a negative effect on the refrigeration performance and it needs to be replaced immediately.
  • Page 11: Troubleshooting

    METOS Maxiglass Noverta 05.10.2012 Troubleshooting Always remove the plug from the socket when carrying out cleaning and repairs The cabinet does not start. • Check the plug. • Restore the power supply by replacing a fault fuse or by using the on/off switch.
  • Page 12: Technical Information

    05.10.2012 METOS Maxiglass Noverta Technical information Power supply 220...240V /50 Hz / 1 Refrigerant R134a Cooling capacity 240W* (5,08CC) Thermostate Electronic Temperature range +1...18°C (set value +6°C) TYPE MG1/140RGCS MG1/140RG MG1/140LGCS MG1/140LG Power con- 173 W* 173 W* 173 W*...
  • Page 13 METOS Maxiglass Noverta 05.10.2012 TYPE MG1/150SD Power con- 173 W* sumption Volume 150 l Weight 58 kg llumination 1 x 3 W Capacity 2x 50 kg/ door tray Dims. 602x506x900/910 mm incl. feet TYPE MG1/250G MG1/250GCS MG1/250DD MG1/250SD MG1/250DDCS Power con-...
  • Page 14 05.10.2012 METOS Maxiglass Noverta TYPE MG1/315G MG1/315GCS MG1/315SD Power con- 316 W* 316 W* 316 W* sumption Volume 315 l 315 l 315 l Paino 103 kg 103 kg 103 kg llumination 1 x 4 W 1 x 4 W...
  • Page 15 METOS Maxiglass Noverta 05.10.2012 CE declaration of conformity for machines (directive 2006/42/EC, Appendix II, sub A) Manufacturer: Gamko BV Address: Mon Plaisir 75 4879 AL, Etten-Leur The Netherlands Herewith declares that Gamko product range type: • MG1/ Is provided as defi ned in: •...