Advertisement

Quick Links

XP1200i/XP1600i/XP2000i/XP3000i
POWER INVERTER
OWNER'S MANUAL
XP1200i
XP1600i
XP2000i
XP3000i

Advertisement

Table of Contents
loading

Summary of Contents for Whistler Group XP1200i

  • Page 1 XP1200i/XP1600i/XP2000i/XP3000i POWER INVERTER OWNER’S MANUAL XP1200i XP1600i XP2000i XP3000i...
  • Page 2 If you have questions concerning the operation of this Whistler product please call customer service: 1-800-531-0004 Hours: Monday - Friday 8:00 am - 5:00 pm CT or visit www.whistlergroup.com Please keep your purchase receipt in a safe place. You may register your product online at www.whistlergroup.com.
  • Page 3 RV. They’re great for weekend use and life on the road. They’re also great for power outages. To fully acquaint yourself with the operation of this power inverter, we recommend reading this entire manual. Sincerely, THE WHISTLER GROUP, INC.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS Features Description ............... 3 Important Information ............. 6 Inverter Information ..............7 • Getting Started • Don’t Push It Battery Information ..............9 • Selecting the Optimum Power Source Cable Information ..............11 • Wire Cable Gauges Operation ................
  • Page 5: Features Description

    12 volt automobile and marine batteries or from portable high power 12 volt sources. XP2000i & up models XP1200i & XP1600i 6 4 2 NOTE: Front panel layout and controls are similar for models 1200 watt and up.
  • Page 6: Inverter Features

    FEATURES DESCRIPTION Inverter Features Three North American AC Outlets Remote Operation Jack The inverter is designed to be operated from a remote location via a WHISTLER Remote Control Switch (P/N Pro-RS01) which plugs into this socket. This optional accessory is available through WHISTLER or your WHISTLER dealer.
  • Page 7 FEATURES DESCRIPTION • Under Voltage Protection. The inverter will turn itself off when the input is less than 10.0+/-0.5 volts DC. • Overload Protection. The inverter will turn itself off when the continuous draw or the surge draw of the equipment being operated exceeds the maximum power rating for the inverter.
  • Page 8: Important Information

    IMPORTANT INFORMATION This manual will provide you with directions for the safe and efficient operation of your WHISTLER inverter. Read the manual carefully before using your new WHISTLER inverter and keep the manual on file for future reference. NOTE: Your WHISTLER inverter is designed to operate from a 12 volt power source only.
  • Page 9: Inverter Information

    INVERTER INFORMATION Getting Started Power equipment and appliances which operate with motors or tubes require an initial surge of power to get them up and running. This power surge is referred to as the “starting load” or “peak load”. (By comparison, electrical devices such as standard light bulbs do not require a large starting load.) Once the equipment or appliance has been powered up, it settles down to a slower pace and requires far less electrical power to...
  • Page 10: Don't Push It

    INVERTER INFORMATION Don’t Push It. Although your Whistler power inverter has the capacity to provide power output (excess current) equal to approximately two times its rated wattage capacity for a very brief period, it is designed to operate equipment and appliances with start up load wattage ratings no higher than its own maximum continuous wattage rating.
  • Page 11: Battery Information

    BATTERY INFORMATION If a piece of equipment or an appliance will not operate, first confirm that the inverter has been properly connected to the 12 volt power source. If all connections have been properly made, turn the inverter rocker switch ON (l), OFF (O) and ON (I) again in quick succession.
  • Page 12 BATTERY INFORMATION 3. Conclusion: The reserve power of the battery is sufficient to satisfy the continuous load demand placed on the inverter for a maximum of about one hour. (49.8 Ah divided by 50A = 1 hour). NOTE: • When the inverter will be operating equipment or appliances with high continuous load ratings for extended periods, it is not advisable to power the inverter with the same battery used to power your vehicle.
  • Page 13: Cable Information

    #4 gauge wire to make the connections. Within four to six feet, use a minimum of #2 gauge wire for XP1200i, #0 gauge for XP1600i. At distances between six feet to ten feet, use #0 gauge wire for XP1200i, #00 gauge for XP1600i. XP2000i...
  • Page 14: Operation

    OPERATION Check Whistler’s online store for cable availability. Making the Connection. 1. Make certain that the Power switch is in the center OFF (O) position. 2. Connect the cables to the power input terminals at the rear of the inverter and tighten the screws to make a secure connection.
  • Page 15 OPERATION Whistler warranty. • Making the connection between the Positive (+) terminals may cause a spark as a result of current flowing to the capacitors in the inverter. This is a normal occurrence. Due to the potential for sparking, however, it is extremely important that both the inverter and the 12 volt battery be well removed from any possible source of flammable fumes or gases.
  • Page 16 OPERATION 8. Turn the inverter to the ON (I) position. Turn on the equipment or appliance. 9. Plug the USB powered device into the inverter’s USB power port. 10. The USB can be powered independantly of the inverter by turning on the rocker switch to the USB (II) position. NOTE: Indicator LED will not illuminate in this position.
  • Page 17: Important Information On Battery Chargers

    OPERATION Important Information on Battery Chargers Using your inverter with battery chargers for power tools, flashlights, video cameras and laptop computers may cause damage to the inverter or the charging unit. Check with the appliance manufacturer for compatibility with modified sine wave inverters if you’re unsure.
  • Page 18: Additional Safety Features

    ADDITIONAL SAFETY FEATURES Automatic Shut Down & Related Safety Features. This inverter has an unique LED indicator warning light system which operates in conjunction with the automatic shut down feature. These indicator lights operate as follows: GREEN LED: System ready. RED LED: System overload/automatic shut down.
  • Page 19 ADDITIONAL SAFETY FEATURES For You Television Fans & Audiophiles. Although the inverter is shielded and filtered to minimize signal interference, some interference with your television picture may be unavoidable, especially with weak signals. However, here are some suggestions that may improve the reception. 1.
  • Page 20: For You Microwave Chefs

    ADDITIONAL SAFETY FEATURES For You Microwave Chefs. The power rating commonly associated with microwave ovens is the “cooking power” which is the power being “delivered” to the item being microwaved. The actual operating power requirement rating is higher than the cooking power rating and typically is referenced on the back of the microwave.
  • Page 21: Care And Maintainence

    CARE & MAINTAINENCE To maintain your inverter in proper working condition, note the following important safety precautions: • MOISTURE. Keep the inverter dry. Do not expose it to moisture. Do not operate the inverter if you, the inverter, the device being operated or any other surfaces that may come in contact with any power sources are wet.
  • Page 22: Operating Principles

    OPERATING PRINCIPLES Whistler inverters work in two stages. During the first stage, the DC to DC converter increases the DC input voltage from the power source (e.g. a 12 volt battery) to 145 volts DC. In the second stage, the high voltage DC is converted to 115 volts (60 Hz AC) using advanced power MOSFET transistors in a full bridge configuration.
  • Page 23 OPERATING PRINCIPLES Consequently, these meters will not read the RMS modified sine wave voltage correctly and, when measuring your Whistler inverter output, the meters will read about 20 to 30 volts too low. To accurately measure the output voltage of your inverter, use a true RMS reading voltmeter such as a Fluke 87, Fluke 8060A, Beckman 4410, Triplett 4200 or any multimeter identified as “True RMS.”...
  • Page 24: Operation Summary

    OPERATION SUMMARY In Review. • Never attempt to operate your Whistler inverter from any power source other than a 12 volt battery or a group of batteries that total 12 volts. • Always make certain that the power cable terminal connections Negative (-) to Negative (-) and Positive (+) to Positive (+).
  • Page 25 OPERATION SUMMARY • In the event of automatic shut down, turn the inverter OFF (O) immediately. Do not restart the inverter until the source of the problem has been identified and corrected. • To avoid battery drain, always disconnect the inverter when the vehicle is not in use for long periods.
  • Page 26: Troubleshooting

    TROUBLESHOOTING PROBLEM: TV Interference Problem Solution Electrical interference from Add a Ferrite data line filter inverter. on to the TV power cord. This filter is available at electronic supply stores. PROBLEM: Low or No Output Voltage Problem Solution Using incorrect type of Use true RMS reading meter voltmeter to test output See “For You Technical...
  • Page 27: Specifications

    Reduce the load on the inverter to rated continuous power output. XP1200i INVERTER SPECIFICATIONS Maximum Continuous Power ..........1200 Watts Maximum Surge Capability (Peak Power) ......2400 Watts* No Load Current Draw ..............< 1.0A Waveform .............. Modified Sine Wave Operating Input Voltage Range ......
  • Page 28 SPECIFICATION XP1600i INVERTER SPECIFICATIONS Maximum Continuous Power ..........1600 Watts Maximum Surge Capability (Peak Power) ......3200 Watts* No Load Current Draw ..............< 1.0A Waveform ............... Modified Sine Wave Operating Input Voltage Range ......11-15+0.5 Volts DC AC Receptacle ........Three North American 3 Prong USB Port ................
  • Page 29: Warranty Information

    WARRANTY Consumer Warranty This Whistler product is warranted to the original purchaser for a period of two (2) years from the date of original purchase against all defects in materials and workmanship, when purchased from an authorized Whistler retailer. This limited warranty is void if the unit is abused, misused, modified, installed improperly, or if the housing and/or serial numbers have been removed.
  • Page 30 WARRANTY 1. Ship the unit in the original carton or in a suitable sturdy equivalent, fully insured, with return receipt requested to: Whistler Repair Dept. 1412 South 1st St. Rogers, AR. 72756 Please allow 3 weeks turnaround time. IMPORTANT: Whistler will not assume responsibility for loss or damage incurred in shipping.
  • Page 31: Service Out Of Warranty

    • The unit has been misused, abused, modified, installed improperly, or had its housing removed. The out of warranty service fee for these inverters are as follows: XP1200i inverter is $75.00 XP1600i inverter is $95.00 XP2000i inverter is $125.00 XP3000i inverter is $185.00 If you require out of warranty service, please return your unit as outlined in the section “Service Under Warranty”...
  • Page 32 Bentonville, AR 72712 Toll Free (800) 531-0004 TEL (479) 273-6012 FX (479) 273-2927 www.whistlergroup.com CUSTOMER RETURN CENTER 1412 South 1st St. Rogers, AR 72756 Customer Service Tel (800) 531-0004 Email: info@whistlergroup.com P/N 401566 Rev.2 © 05/2014 The Whistler Group, Inc.

This manual is also suitable for:

Xp1600iXp2000iXp3000i

Table of Contents