  • Page 1 - 1 -...
  • Page 2: Table Of Contents

    Contents 1. Safety Point for Attention...................................... 1 2. Parts & Subassemblies ......................................2 3. Check-ups before Operation ....................................3 4. Starting of generator......................................6 5. Usage of Generator ........................................ 9 6. Stopping of generator ......................................12 7. Maintenance ......................................... 13 8.
  • Page 3: Safety Point For Attention

    1. Safety Point for Attention 1) Do not use it indoors 2) Do not open it in wet 3) Do not connect it to the line for house Environment appliance 4) keep flammables 1m 5) Do not overfill to cause over- Min.
  • Page 4: Parts & Subassemblies

    2. . . . Parts & Subassemblies 1) Fuel indicator 9)Starting handle 2)Fuel tank up 10)Fuel filter cup 3)AC socket 11)Fuel valve 4)AC breaker 12)Air filter 5)Voltmeter 13)Choke handle 6)Machine oil plug gap 14)Exhaust silencer 7)Engine switch 15) Spark plug 8)Discharging bolt 16)Grounding terminal - 2 -...
  • Page 5: Check-Ups Before Operation

    3. . . . Check-ups before Operation · · · · Scope of temperature the genertor set is appli- Cable for.-15 5 5 5 ℃ ℃ ℃ ℃ to 40 to 40 to 40 to 40℃ ℃ ℃ ℃ ..·...
  • Page 6 . . . . Level of fuel C. Remount the cap A. Check the fuel level on the fuel indicator B. If the fuel level is too low,serew off the fuel tank cap fill it with 3. Air filter Fuel to the shoulder of the filter. A.
  • Page 7 C. . . . It is dirty ,take out the element for cleaning 4.Battery · · · · Wash it in solvent · · · · Squeeze dry Check to make sure that the electrolyte levelin every call is · · · · Drop some drips of machine oil into it. Between the upper and lower limit lines.
  • Page 8: Starting Of Generator

    4. . . . Starting of generator Starting with kick starter 4. Turn the choke handle to “CLOSE” positioon 1. Remove all loads from the AC output terminal. Caution: DO not close the choke when starting a hot engine. 2. Turn off the AC circuit breaker. 5.Turn on the engine switch.
  • Page 9 6. . . . Gently hold the starting pull handle till some resistance is felt Electric start and then 1. Remove all loads from the output terminal Pull it abruptly. 2. Turn of the AC breaker. Waring: Never let the starting pull handle retract suddenly but return it gently.
  • Page 10 4. . . . Set the choke handle to “Close” position 6. Release the electric start. Caution: Do not close the choke when starting a hot engine 7: When the engine is warmed up,set the cloke handle to “Open” position 5: Turn on the electronic start switch.
  • Page 11: Usage Of Generator

    5. Usage of Generator To keep the generator in optimal con- Dition mechanically and electrically the Following points shall be observed. Warning: The generator has to be Ground for fear that any mistake would Be made electrically. The total power of electric load shall not exceed the rated power of the generator.
  • Page 12 When two or more loads are to be connected to the · Generator can’t work over load.It should be no more than generator,they shall be connected from the one requiring larger current to that requiring a small one. Of rated power with load for long run. ·...
  • Page 13 4: Connecting the AC breaker Note: Over current will automatically turn off the AC breaker. When that is turned off,the generator shall be restarted with load reduced a few minutes thereafter. Use of AC 1. Starting the engine. 2. Ensuring that the voltmete indictes voltage. 3.
  • Page 14: Stopping Of Generator

    6. . . . Stopping of generator 1.Turn off the AC breaker. 3. Remove all loads. 4. Close the fuel valve. 2. Turn off the engine switch Note:When an emergent stop of the engine is needed,turn the generator switch to “OFF” position. - 12 -...
  • Page 15: Maintenance

    Mainte nance - 13 -...
  • Page 16 1. . . . Replacing machine oil 2. Spark plug Open the filling hole. 1. Remove the spark plug cap. Remove the oil discharging bolt and drain off the used 2.Remove the spark plug. 3. Remove carbon deposit. 4. Check the spark plug gap Remount the oil discharging bolt tightly.
  • Page 17 5. . . . Remount the spark plug and its cap 3. Clean the cup and screen. 4. Remount the cup and screen 3. Fuel filtering cup 1. Close the fuel valve 2. Remove the setting cup and straining screen. - 15 -...
  • Page 18: Storage

    8. . . . Storage 1. Drain off fuel from the fuel tank. 5. Remount the dis- 2. Clean and then remount the straining screen and setting Charging bolt tightly,fill Cup. The machine with fresh Machine oil to the upper Limit mark and then re- Mount the gage.
  • Page 19: Troubleshooting

    9. . . . Troubleshooting The engine can not start: - 17 -...
  • Page 20 There is no Voltage? Check the circuit protector. Check the spark plug - 18 -...
  • Page 21: Technical Data

    10. Technical data Item Model TI9000LXU / TI9000LXT Rated Voltage (V) 120V / 240 Rated output (KW) Max. output (KW) Rated Frequency (Hz) Power factor Voltage regulate Self-excited conxtant voltage Engine model 190FD Bore × stroke (mm) 90 × 66 Compression ratio 8.0 : 1...
  • Page 22: Battery Unit

    11. Battery Unit ( Electric ) 1. Mount the battery unit reliably in position with bolts, nuts and washers. 2. Get the electric start cable through under the tank and connect it to the solenoid. 3. Connect the grounding wire to the rear end of the generator. 4.
  • Page 23 Instruction of Using / Maintaining Generator Maintainance – free Battery Respected Customers: Kindly read the instruction carefully before using the maintainance – free battery, which is composed of three parts. Part one: how to use the battery; part two: how to change the battery; part three: how to maintain the battery. Part one: how to use the battery 1.
  • Page 24 ★ ★ ★ ★ Forbidden: not charge the battery in a long time. ★ ★ ★ ★ 4. Charge the battery within the restricted voltage (13.8V ~ ~ ~ ~ 14.4V), or there will be serious result. Part two: how to charge the battery 1.
  • Page 25: Wheel Unit

    12. Wheel Unit ( Pick out and buy ) 1. Fix the four wheels to the axle by washers and pins. 2. Fix the wheel axle to the generator by bolts and nuts. 1) Internal side 2) Shorter side 3) Longer side 4) Wheel lock pin 5) Lock dise 6) Engine side...
  • Page 26 LOOSE PARTS LIST The following items are included with the generator: No. Description ……………………… Qty Wheel …………………………… Wheel Axle ……………………… 2 Large Cotter Pin ……………… Small Cotter Pin ……………… Clevis Pin ……………………… Handle ………………………… Bolt …………………………… Frame Support with Foot ……… 2 - 24 -...
  • Page 27 UNPACKING 2 small cotter pins 2 large cotter pins This product requires assembly. ■ Remove one end of the box and carefully slide out the ■ Raise generator and any accessories. generator opposite the recoil NOTE: The generator is heavy. If you must lift the unit out of the starter high enough to gain box, get another person to help you and lift with your legs, not access to the frame bottom;...
  • Page 28 ■ Insert a large cotter pin through the hole in the axle. ■ Locate the following item: Bend the ends of the pin to secure. 2 handles 2 clevis pins ■ Repeat the process on the other side. 2 small cotter pins ■...
  • Page 29: Automatically Gasoline Generator Manual

    13. Automatically Gasoline Generator Manual Ⅰ Ⅰ Ⅰ Ⅰ . Introduction Automatically Gasoline Generator is the intelligent generator without the operation by Man. It will be automatically started and stooped when power cut and come. It could also automatically adjust the choke to fit the different temperature environment to let the generator reliably start during the range of the pointed temperature.
  • Page 30 Ⅲ Ⅲ Ⅲ Ⅲ . The operating procedure of automatically control generator 1. Inspection and connection before use the generator B. Automatically controlled condition A. lock switch: place to “OFF” If the power network is power off, the work indicating light B.
  • Page 31 3. . . . Maintenances Notice IV. The indication of working condition A. Control switch must be put to “OFF” and disassemble the 220V 1. Stand-by indicating: light “ON” power inlet before manual operating,manual/electrical starting or 2. Generator power outlet indicating: light “OFF” maintaining or changing the bettery.
  • Page 32 - 30 -...
  • Page 33 - 31 -...
  • Page 34 - 32 -...

Table of Contents