INSTALLATION MANUAL
FOR Solartec PHOTOVOLTAIC
MODULES
S60MC series
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important safety
instructions for the PV module that must be
followed during the installation and the
maintenance of PV modules.
PLEASE READ THIS MANUAL CAREFULLY BEFORE
INSTALLING OR USING THE MODULES.
PLEASE PASS ALONG THIS MANUAL TO YOUR CUSTOMER.
INTRODUCTION
Thank you for choosing Solartec (PV) module
This Installation Manual contains essential
information for electrical and mechanical
installation that you must know before
installing Solartec modules. This Manual also
contains safety information you need to be
familiar with. All the information described in
this Manual is the intellectual property of
Solartec and is based on the technologies and
experience that have been acquired and
accumulated over the long history of Solartec.
This Manual does not constitute a warranty,
expressed or implied. Solartec does not
assume responsibility and expressly disclaims
liability for loss, damage, or expense arising
out of or in any way connected with
installation, operation, use or maintenance of
PV modules. No responsibility is assumed by
Solartec for any infringement of patents or
other rights of third parties that may result
from use of PV modules. Solartec reserves the
right to make changes to the product,
specifications or Installation Manual without
prior notice.
The mechanical and electrical installation
of PV systems should be performed in
accordance with all applicable codes; including
electrical codes, building codes, and electric
utility interconnect requirements. Such
requirements may vary for mounting location,
such as building rooftop or motor vehicle
applications. Requirements may also vary with
system voltage, and for DC or AC application.
Contact local authorities for governing
regulations.
Photovoltaic
electricity when exposed to light and
therefore can produce an electrical shock or
.
burn. Modules produce voltage even when
not connected to an electrical circuit or load.
Modules produce nearly full voltage when
exposed to as little as 5% of full sunlight and
both current and power increase with light
intensity. Use insulated tools and rubber
gloves when working with modules in
sunlight.
PV modules have no on/off switch.
Modules can be rendered inoperative only by
removing them from sunlight, or by fully
covering their front surface with cloth,
cardboard, or other completely opaque
material, or by working with modules face
down on a smooth, flat surface.
Modules can produce higher output than
the rated specifications. Industry standard
ratings are made at conditions of 1000
watts/m2
Reflection from snow or water can increase
Codes and Regulations
Safety Precautions
modules
and
25°C
cell
produce
DC
temperature.

Advertisement

loading
Need help?

Need help?

Do you have a question about the S60MC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Solartec S60MC Series

  • Page 1 Manual is the intellectual property of sunlight. Solartec and is based on the technologies and PV modules have no on/off switch. experience that have been acquired and Modules can be rendered inoperative only by accumulated over the long history of Solartec.
  • Page 2 “landscape” or “portrait.” typically face north. Please make sure that There are several approved ways to mount there are no obstructions in the surroundings these Solartec Modules to a support structure. site installation. Artificially They may be mounted either using the bolt...
  • Page 3 as show in Dimensions (back view of the connected in parallel or used in conjunction module) and Figure 1 (mounting detail). with a battery. If the modules are installed in The module should be fastened with four (4) parallel electrically, each module (or series stainless steel M8 (5/16”) bolts, stainless steel string of module so connected) shall be M8 washers, stainless steel M8 spring washers...
  • Page 4 safety. The grounding connections between modules must be approved by a qualified electrician, the grounding itself must be made by a qualified electrician. Recommended torque value 2.3N.m (20in-lb). grounding clip accepts solid uninsulated copper wire sizes 10 or 12 AWG. The wire must not be nicked Figure 3 Notice: Use TYCO.