Henley Stove Lisbon 400, Lisbon 500, Lisbon 700, Lisbon 900 Installation And Operating Manual

Advertisement

Henley
Stoves
PLEASE READ ALL THESE INSTRUCTIONS CAREFULLY!
For safety reasons it is essential that your stove is correctly installed and operated.
Henley Stoves cannot accept responsibility for any fault or consequential problems
arising through incorrect installation or operation.
Important: – This product must be installed by a suitably qualified installer.
The Heating Specialists
Lisbon 400, 500, 700, 900
Installation and Operating Manual
"Every Home Deserves A Henley"

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lisbon 400, Lisbon 500, Lisbon 700, Lisbon 900 and is the answer not in the manual?

Questions and answers

Summary of Contents for Henley Stove Lisbon 400, Lisbon 500, Lisbon 700, Lisbon 900

  • Page 1 Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Lisbon 400, 500, 700, 900 Installation and Operating Manual PLEASE READ ALL THESE INSTRUCTIONS CAREFULLY! For safety reasons it is essential that your stove is correctly installed and operated. Henley Stoves cannot accept responsibility for any fault or consequential problems arising through incorrect installation or operation.
  • Page 2: Table Of Contents

    “Every Home Deserves A Henley” Congratulations on your purchase of your Henley Stove. With the proper care and attention your Henley stove will give you a lifetime of heat, comfort and pleasure. This manual contains instructions on how to install and maintain your Henley Stove.
  • Page 3: Technical Specification

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Lisbon 700 Henley Technical Specification Stoves Drawing All dimensions are correct at time of printing but may be subject to slight change. Please confirm exact dimensions of your new stove prior to commencing installation works Height: 620 | Width: 758mm Depth: 370mm | Flue Dimentions: 153mm...
  • Page 4: Stove Commissioning Checklist

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Stove Commissioning Checklist Please complete the form below as it will be of great assistance in the unlikely event that there is a problem with the stove or a warranty claim needs to be made. Please contact the installer or dealer if there is a problem. Dealer appliance was purchased from Name: Address:...
  • Page 5: Installation Instructions

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Installation Instructions 1. Before installation and/or use of this appliance please read these instructions carefully to ensure that all requirements are fully understood. The appliance must be fitted by a registered installer*, or approved by your local building control officer.
  • Page 6: Ventilation

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Ventilation This appliance requires a constant supply of air to maintain proper combustion and effective flue performance. An inadequate air supply can result in poor combustion and smoke entering the room which is potentially dangerous.
  • Page 7: Flue Positions

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Flue Positions These positions are defined by Document J of the Building Regulations. Seek specialist advice if installing in a dwelling with a thatched roof Horizontal Terminal Adjacent Measurement Flue Building 150mm Vertical...
  • Page 8: Height Over Roof

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Height Over Roof Outlet of a chimney or a flue to be not less that 1m above the highest point of contact of chimney and roof. Where the roof has a pitch of more than 10º...
  • Page 9: Flue Options - Top/Rear

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Flue Options - Top Flue from top of stove External Air Supply If not using External Air Supply do not remove cover from back of outlet. The stove can then be fluedl ike a standard stove Flue Options - Diagram We recommend flexi liner is...
  • Page 10: The Clean Air Act 1993 And Smoke Control Areas

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” The Clean Air Act 1993 And Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area.
  • Page 11: Lighting The Stove

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Lighting The Stove We recommend that you have two or three small fires before you operate your stove to its maximum heat output. This is to allow the paint to cure in steadily and to give a long service life of the paint finish. During this curing in process you may notice an unpleasant smell whilst the finishes finally cure.
  • Page 12: Operation With Door Left Open

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Operation With Door Left Open Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left open. Dampers Left Open Operation with the air controls or dampers open can cause excess smoke. The appliance must not be operated with air controls or dampers door left open except as directed in the instructions.
  • Page 13: Maintenance - Replacing The Fire Rope Around Your Stove Door

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Maintenance - Replacing The Fire Rope Around Your Stove Door Periodically visually check over the door rope seal for any damage, cuts or tears and detached sections. The rope gasketing can be replaced, using a universal roping kit. Instructions for rope replacement are as follows: •...
  • Page 14: Maintenance - Replacing The Glass In Your Stove Door

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Maintenance - Replacing The Glass In Your Stove Door Replacing the glass in your stove door In the event of the door glass being broken it can easily be replaced using the following procedure: •...
  • Page 15: Air Control

    Henley Stoves appliances have air systems providing cleaner burning, and greater efficiency and control, please see the diagram to view where the various air controls are located on your Henley Stove. 1. Primary Air - Turning this wheel anti-clockwise opens the primary air and allows air into the stove. You would normally open this wheel when starting a fire to allow air into the stove for maximum combustion.
  • Page 16: Stove Finish (Paint)

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Stove Finish (Paint) The outside of the stove is finished in a durable high temperature paint. It is best cleaned by brushing down with a soft brush. Do not allow water to remain on the surface when cold or rust may occur. The high temperature paint finish should not require attention for some time, depending on use.
  • Page 17: Parts

    “Every Home Deserves A Henley” Parts Over time you may require replacement parts for your Henley Stove. Replacement parts are available through your local stockist. Please use the below diagram to establish the part you require for your stove. Please ensure you quote the model name and also the serial number of the stove when orderig your spare parts.
  • Page 18: Safety

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Safety A fireguard conforming to BS 8423:2010 should be used in the presence of children, the old or infirm. Please note, this appliance should be used with the fire door closed at all times except when fuelling, de-ashing or initial lighting.
  • Page 19: Frequently Asked Questions

    Henley The Heating Specialists Stoves “Every Home Deserves A Henley” Frequently Asked Questions Why are my air inlets puffing smoke? Combustion gases can build up in the firebox and ignite as small explosions, causing smoke to puff out of the air inlets and other openings.
  • Page 21: Warranty Form

    Henley Warranty Form Stoves You need to register your warranty online or via the post in order to activate the warranty for your stove. The appliance needs to be installed by a HETAS approved fitter and in accordance of Building Regulations to be valid. In the event you require a service engineer to inspect the appliance, a standard charge of €120 is payable prior to any inspection.