GONU14RS User’s manual www.xtendlan.com Product Introduction The GONU14RS is a GEPON ONU terminal, which complies with the IEEE 802.3ah standard and the CTC2.0 standard. The device provides one EPON interface, four 10/100BASE-T Ethernet interfaces, one CATV RF connector, and two FXS VoIP interfaces. The EPON interface provides passive Ethernet access and 1.25G symmetrical broadband data transmission.
GONU14RS User’s manual www.xtendlan.com G.711, G.726, G.729 voice coding RFC2833 DTMF T.38, G711 FAX transparent pass-through mode Special service of VoIP UART CONSOLE port 1.3 LED Indicators and Interfaces Front Panel Figure 1 Front panel...
Page 6
GONU14RS User’s manual www.xtendlan.com Color Status Description The receiving optical power of the Blinks ONU is lower than the sensitivity of the optical receiver. PON_LOS The receiving optical power of the ONU is normal. The phone is registered to the SIP Server.
GONU14RS User’s manual www.xtendlan.com Item Parameters Specifications FDA 21CFR 1040.10 and 1040.11 Laser eye safety EN (IEC) 60825-1 EN (IEC) 60825-2 Green standard RoHS L x W x H: 218 mm x 172 mm x 41 Physical...
GONU14RS User’s manual www.xtendlan.com 1.6 Environment Requirements Item Specifications Operating temperature 0ºC~40ºC Storage temperature -40ºC~75ºC Operating humidity 10%~90%, non-condensing Storage humidity 5%~95%, non-condensing Power Power adapter output: 10.8 V~13.2 V DC 1.7 Safety Precautions Refer to the following instructions to protect the device from risks and damage caused by fire and electric power: ...
The GONU14RS uses special external power adapter of 12 V DC. 2.2 PON Interface The optical interface of the GONU14RS is an SC/APC interface and is on the right of the rear panel. During setup, remove the plastic dust cap of the SC/APC interface and keep it well for future usage.
ONU, the fiber connector of the fiber line, or the uncovered area of the fiber. 2.3 Ethernet Interface The GONU14RS provides four channels of general Ethernet service interfaces of standard RJ45 connectors. The general Ethernet service interface is of MDI/MDI-X self-adaptation. You can use either crossover cable or straight-through cable.
GONU14RS User’s manual www.xtendlan.com Definition Color Null Brown Table 2 Pinout of crossover cable at Ethernet RJ-45 port Definition Color RXD+ Green and white RXD- Green TXD+ Orange and white Null Blue Null Blue and white TXD- Orange Null Brown and white...
GONU14RS User’s manual www.xtendlan.com Username: Admin Password: Admin 3.2 Home Page The HOME page is as follows. Parameters in this page are described as follows: Field Description System Uptime The interval since the last system start-up. Connection status of the LAN interface. In this case, it is the connection status of the VoIP interface.
GONU14RS User’s manual www.xtendlan.com Field Description Provisioning Connection status of the Provision. Status Whether the voice service is started. If at least one Voice Service phone is registered to the SIP Server, the value of this field is UP. Otherwise, it is DOWN.
Page 15
GONU14RS User’s manual www.xtendlan.com IP Settings Unmanaged: Do not configure the IP address information of the LAN interface. Obtain an IP address automatically: Obtain an IP address through DHCP from LAN side. IP Address: The IP address obtained by DHCP.
GONU14RS User’s manual www.xtendlan.com Lease Time: The lease time of DHCP Server. – Enable DHCP Relay: Enable DHCP proxy function. Relay IP: The IP address of DHCP proxy. Server and Relay Off: Disable DHCP Server and DHCP proxy on the LAN side.
Page 17
GONU14RS User’s manual www.xtendlan.com PPP Settings: Username: User name of PPPoE – Password: Password of PPPoE – Keep Alive: Keep alive time of PPPoE. – Authentication: Select the authentication mode of PPPoE. – MTU: Maximum transmission unit of PPPoE –...
Page 18
GONU14RS User’s manual www.xtendlan.com For setting the static IP address, see the following figure: Static Settings IP Address: Set the IP address. – Mask: Set the subnet mask. – MAC: Ethernet address – Restore: Restore the default Ethernet address.
Page 19
GONU14RS User’s manual www.xtendlan.com After setting the parameters, click Apply to apply the settings immediately. Because the configuration is lost if the IAD is powered off, you must click Save All in the System Command page from the Tools menu. See the following...
GONU14RS User’s manual www.xtendlan.com After setting the parameters, click Apply to apply the settings immediately. Because the configuration is lost if the IAD is powered off, you must click Save All in the System Command page from the Tools menu. See the following figure: 3.4 Advanced Configuration of Network Interface...
GONU14RS User’s manual www.xtendlan.com 3.5.1 Provision Configuration With the provision function, the IAD can automatically upgrade configuration files and system IMAGE in the specified address. Click Provisioning in the left pane and the Provision Configuration page appears: Parameters are described as follows:...
GONU14RS User’s manual www.xtendlan.com Field Description Storage path of the configuration file for Provisioning Profile Base upgrade. The value of this field can be HTTP or TFTP address. Storage path of the Image file for upgrade. Image Firmware Base URL The value of this field can be HTTP or TFTP address.
Page 23
GONU14RS User’s manual www.xtendlan.com Parameters are described as follows: Field Description Register status of the channel. That is, REG_STATUS whether the channel is registered to the SIP Server. Time of RTP packaging. The value can be Packet_TIME 10 ms, 20 ms, or 30 ms. The default value is 20 ms.
Page 24
GONU14RS User’s manual www.xtendlan.com Field Description IP address or domain name of the SIP PROXY_FQDN proxy. PROXY_PORT Port number of the SIP proxy. IP address or domain name of the SIP REG_FQDN registered server. REG_PORT Port number of the SIP registered server.
Page 25
GONU14RS User’s manual www.xtendlan.com Field Description function, and the value indicates the specific time interval. VAD_ENABLE Enable voice activity detection (VAD). EC_ENABLE Enable echo cancellation. MWI_STATE The status of MWI. Enable multi-way conference. This function NWAY_CONF is not supported. Enable call waiting, when working with CW_DEFAULT CALL_WAITING.
GONU14RS User’s manual www.xtendlan.com Field Description Enable call waiting when working with CALL_WAITING CW_DEFAULT. If this service is enabled and a NOTIFY message is received in the voice mailbox, you can hear intermittent dialing tone after picking up the receiver. Otherwise, you hear the normal dialing tone.
GONU14RS User’s manual www.xtendlan.com Click Save All to save all configurations. 3.6.2 Restoring Default Configuration Click System Commands > TOOLS and the following page appears:...
GONU14RS User’s manual www.xtendlan.com Parameters are described as follows. Field/Button Description Provisioned Parameters Relevant voice configuration. Non-Provisioned Other configuration parameters. Parameters Restore the selected configuration to Restore Defaults factory default configuration. 3.7 Online Update of Image/Configuration Choose TOOLS > Update Gateway and the following page appears:...
Page 29
GONU14RS User’s manual www.xtendlan.com Select the Image file or configuration file for update and click Update Gateway. The update process is as shown in the following page:...
Page 30
GONU14RS User’s manual www.xtendlan.com After the upgrade is complete, the page shown in the following figure appears:...
Page 31
GONU14RS User’s manual www.xtendlan.com If you update the Image file, the system automatically reboots after the update is complete. If you update the configuration file, you need to manually reboot the system.
GONU14RS User’s manual www.xtendlan.com VoIP – Supplementary Services Feature codes of the supplementary services are as follows: Supplementary Service Type Feature Code Call transfer with no consultation Call transfer with third-party consultation Three-way conferencing Call return Redial when busy Cancel call waiting...
GONU14RS User’s manual www.xtendlan.com In the Voice Parameters page, enable CALL_TRANSFER. In the conversation, press the cradle to hold B. Press <#90>+<transferred number> to transfer the call. 4.3 Call Transfer with Third-Party Consultation Description: A and B are in a conversation. A presses the Flash key to hold the conversation with B, and dials a feature code to call C.
GONU14RS User’s manual www.xtendlan.com 4.6 Redial when Busy Description: A calls B, B is busy, A hangs up, and waits for some time, and automatically calls B. Operation: In the Voice Parameters page, enable REPEAT_DIAL. Perform an outgoing call and the other party is busy. Press <#5>...
GONU14RS User’s manual www.xtendlan.com 4.8.2 Call Forwarding when Busy Description: This function forwards incoming calls to a preset number when the local party is busy. Operation: In the Voice Parameters page, enable Call forwarding. Pick up the phone and press <*74>+<forwarding number>, to activate call forwarding when busy.
GONU14RS User’s manual www.xtendlan.com Acronyms and Abbreviations In the Voice Parameters page, enable DO_NOT_DISTURB. Pick up the phone and press <*78>, to activate the do not disturb function. Pick up the phone and hang up, to deactivate the do not disturb function.
Page 37
Appendix A Acronyms and Abbreviations CATV Community Antenna Television EPON Ethernet Passive Optical Network Dynamic Bandwidth Allocation Forward Error Correction FTTB Fiber to The Building FTTH Fiber To The Home IGMP Internet Group Management Protocol Optical Line Terminal Optical Network Unit Passive Optical Network Quality of Service SLIC...