Summary of Contents for Eclipse Security ECL-IPSP220I
Page 1
ECL-IPSP220I User’s Manual Version 1.3.0...
Page 2
Table of Contents FEATURES AND FUNCTIONS ..................1 General Introduction..............................1 Features ..................................1 1.2.1 On-Screen Menu..............................1 1.2.2 Proportional Pan and Tilt ............................1 1.2.3 On-screen Tips...............................1 1.2.4 Preset Setup and Call ............................1 1.2.5 Auto Scan................................1 1.2.6 Auto Touring ................................1 1.2.7 Auto Pattern................................1 1.2.8 Privacy Masking ..............................1 1.2.9 Action on Alarm..............................2...
MENU ..........................9 Screen Menu Index ..............................9 Self-diagnosis System Information ........................10 Main Menu .................................10 Menu Operation ..............................11 4.4.1 System Information..............................11 4.4.2 Display Setting ..............................12 4.4.3 Camera Setting ..............................12 4.4.4 Function Setting ..............................16 4.4.5 IR Light Setup...............................24 Dome Abnormal Phenomenon Operation ......................25 4.5.1 Restore to Factory Default Setup ........................25 4.5.2...
Page 4
Welcome Thank you for purchasing our product! This user’s manual is designed to be a reference tool for the operation of your system. Here you can find information about this speed dome features and functions, as well as a detailed menu tree. Please keep it well for future reference! Before installation and operation, please read the following safeguards and warnings carefully!
Page 5
Important Safeguards and Warnings 1.Electrical safety All installation and operation here should conform to your local electrical safety codes. We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation. We are not liable for any problems caused by unauthorized modification or attempted repair. 2.Transportation Security No heavy stress, violent vibration or water splash are allowed during transportation, storage and installation.
Page 6
Before installation, please open the package and check that all the components are included in the package: Contact you local retailer ASAP if something is missing in your package.
1 Features and Functions 1.1 General Introduction This series IR network intelligent speed dome product is an integrated high intelligent speed dome. It adopts new configuration design and is easy for the project construction. This is a digital and intelligent product of vivid video.
1.2.9 Action on Alarm This series IR high definition speed dome has 7 alarm inputs (normal open or normal close) and 2 alarm outputs (normal open). Alarms can be individually programmed to initiated pattern, or go to an associated preset, scanning, touring when received. Dome will return to a previously programmed state after alarm acknowledgement or to its previous position before alarm.
2 Quick Configuration Tool 2.1 Overview Quick configuration tool can search current IP address, modify IP address. At the same time, you can use it to upgrade the device. Please note the tool only applies to the IP addresses in the same segment. 2.2 Operation Double click the “ConfigTools.exe”icon, you can see an interface is shown as in Figure 2-1.
Page 10
Figure 2-3 If you want to modify the device IP address without logging in the device web interface, you can go to the configuration tool main interface to set. In the configuration tool search interface (Figure 2-1), please select a device IP address and then double click it to open the login interface.
Page 11
Figure 2-5 For detailed information and operation instruction of the quick configuration tool, please refer to the Quick Configuration Tool User’s Manual included in the resources CD.
3 Web Operation This series IPC product support the Web access and management via PC. Web includes several modules: live view, PTZ, set, alarm, logout and etc. IP camera factory default setup: IP address: 192.168.1.108. User name: admin Password: admin 3.1 Network Connection Please follow the steps listed below for network connection.
Page 13
Figure 3-2 After installation, the interface is shown as below. See Figure 3-3. Please input your user name and password. Default factory name is admin and password is admin. Select the network connection type. The login type includes: TCP/UDP/Multicast. Note: For security reasons, please modify your password after you first login. Figure 3-3 After you logged in, you can see the main window.
Page 14
Figure 3-4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction.
4 Menu 4.1 Screen Menu Index Note: ERR means current setup is invalid; you need to restores speed dome factory default setup. Slight difference may be found due to different series. SYSTEM INITIAL INFORMATION… INFORMATION ADDR INFORMATION… SYSTEM TIME SETTING… SET NORTH LANGUAGE :ENGLISH...
Note: ERR means current setup is invalid. Please make sure all the cable connections are right. 4.2 Self-diagnosis System Information ADDR :001-H BAUD RATE :9600 PARITY :NONE SOFTWARE :V1.02.0.RHNDDC BACK EXIT After installation, please connect speed dome to power. The system goes on a self-diagnosis, and then it pops up the above interface to show the system information.
4.4 Menu Operation In the speed dome main menu, you can use the left/right button on the keyboard or in the speed dome terminal menu to configure the system menu. Before setup, please move the cursor to the current item you want to configure.
ADDR TYPE : HARD ADDR-HARD : 001 ADDR-SOFT : 001 BACK EXIT Move the cursor to SITE INFORMATION and then click confirm button. ADDR TYPE: There are two options: soft and hard. Please use the left/right button on the keyboard or in the speed dome terminal menu to set.
Page 19
WB SETTING EXPOSURE SETTING DAY/NIGHT SETTING FOCUS SETUP ZOOM SPEED : 08 APERTURE : 09 APERTURE CTRL LEVEL :8 NEXT PAGE BACK EXIT Move the cursor to CAMERA SETTING and then click confirm button, you can go to the submenu. WHITE BALANCE SETUP: Move the cursor to current option and then click confirm button, you can go to the third menu.
Page 20
B GAIN: Before you set B GAIN option, please note the mode shall not be auto. Please use the left/right button on the keyboard or in the speed dome terminal menu to set. BACK: Go back to previous menu. EXIT: Log out system menu. 4.4.3.2 Exposure Setting AE MODE : AUTO...
Page 21
3D NOISE REDUCTION: It is to set the speed dome 3D noise reduction setup. Please use the left/right button on the keyboard or in the speed dome terminal menu to set. BLC: It is an abbreviation for back light compensation. System can compensate the object in the dark light to achieve a clear video.
FOCUS LIMIT: It is to set the camera focus limit. Please use the left/right button on the keyboard or in the speed dome terminal menu to set. FOCUS SENSITIVITY: It is to set the camera focus sensitivity. Please use the left/right button on the keyboard or in the speed dome terminal menu to set.
Page 23
PAN: Move the cursor to PAN and then click confirm button to go to the third submenu. AUTO SCAN: Move the cursor to SCAN and then click confirm button to go to the third submenu. AUTO CRUISE: Move the cursor to AUTO CRUISE and then click confirm button to go to the third submenu.
Page 24
Set preset: Set preset 26 or 92 to set scan left limit. Set preset 27 or 93 to set scan right limit. Set preset 22 or 79 to begin record. Set preset 23 or 80 to stop record. 4.4.4.2 Pan PAN SPEED :160 STOP...
Page 25
CRUISE NO: : 001 CRUISE SETTING DELETE CRUISE STOP BACK EXIT Move the cursor to highlight CRUISE item and then click confirm button to go to set interface. CRUISE NO :Here is to ser tour number. Please use the left/right button on the keyboard or in the speed dome terminal menu to set.
Page 26
From the start position, dome begins auto movement repeatedly. This series IP dome supports maximum 5 patterns and one pattern can max support 400 commands. Move the cursor to PATTERN and click confirm button. PATTERN NO: Here is to set pattern number. Please click left/right key to configure. PROGRAM START: Here is to memorize pattern starting point.
Page 27
4.4.4.7 Time Task (Schedule task) TASK NO :1 TIME TASK :OFF TASK SETTING TASK INFORMATION DELETE TASK BACK EXIT • TASK NO: Here you can set task number. Please use the left’/right button to set. • TIME TASK: The schedule task allows the speed dome to implement corresponding setup during the specified time.
Page 28
Task Information Move the cursor to the TASK INFORMATION and then click the confirm button to go to the following interface. Here you can see the corresponding task information. Click the confirm button again, you can exit current interface. TIME ACTION ALL 00:00-00:00 SC001 ALL 00:00-00:00 SC001...
Page 29
• BACK: Go back to the previous menu. • EXIT: Log out the system menu. Privacy Mask Move the cursor to PRIVACY MASK and click confirm button, system goes to privacy mask setup interface. PRIVACY :001 ACTIVATE : OFF RESIZE : ↑...
POWER UP :1 PARAMTER :OFF BACK EXIT • POWER UP: It is to set the PTZ operation when the speed dome boots up. The option includes: NONE/AUTO/SCAN/PRESET/PATTERN/TOUR and etc. Please use the left/right button to set. • PARAMTER: Here you can set the serial number of the corresponding operation such as the scan, preset, pattern, tour.
4.5 Dome Abnormal Phenomenon Operation 4.5.1 Restore to Factory Default Setup From main menu-> SYSTEM INFORMATION, move cursor to FACTORY DEFAULT and click confirm button. Dome will reboot and all the setups restore to factory default setup. 4.5.2 PTZ Movement is not smooth From menu to SYSTEM INFORMATION, move cursor to RESTART and click confirm button.
5 Cable Connection 5.1 Combination Cable Connection The speed dome combination cable includes network cable, audio/video cable connection port, RS485 connection port, alarm input and output port. Please refer to the label for detailed information. Please note the IE6 does not support alarm upload function. Please use IE7 or higher version. If it is your first time to boot up the WEB on the Windows 7 OS, please right click the Internet Explorer icon on the desktop and then select “Run as Administrator”.
5.2.1 System Connection Please refer to Figure 5-1 for system connection information. Network AC220V Power Output Input Output Transfor Figure 5-1 5.2.2 Alarm Connection Please refer to Figure 5-2 for alarm connection information. Figure 5-2...
6 FAQ 6.1 Daily Maintenance Please clean dome cover regularly to get vivid image. Handle the cover with care. Use water to wash. Don’t use cloth to clean. Use mild detergent to clean if there is too much dust. Note: The sweat from your hand may erode plating surface, your nail may scrape dome cover resulting in blur image.
7 Appendix Ⅰ Thunder Proof and Surge Protection This series speed dome adopts TVS lighting protection technology. It can effectively prevent damages from various pulse signals below 1500W, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to take necessary precaution measures when installing the speed dome in the outdoor environment.
8 Appendix 2 Toxic or Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Component Name Cr VI PBDE Sheet Metal ○ ○ ○ ○ ○ ○ Plastic Parts ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...
Page 37
Note • This manual is for reference only. Slight difference may be found in the user interface. • All the designs and software here are subject to change without prior written notice. • All trademarks and registered trademarks are the properties of their respective owners. •...
Need help?
Do you have a question about the ECL-IPSP220I and is the answer not in the manual?
Questions and answers