Rotary switches for unit identification • Power Over Ethernet (PoE) • CobraNet audio/control with dynamic use of available bundles, plus power over single Ethernet cable • Status LEDs to indicate signal and clip • marked and RoHS compliant • Covered by BiAmP Systems’ warranty...
VO-4 frOnt panel Setup and Use The Vocia software provides an intuitive interface for configuration, DSP equalization, and programming of the VO-4. The information supplied by this manual relates to physical connections and assignment. For more details on software setup, please consult the Vocia Help File. Power/ Network Output 4...
VO-4 rear panel cOntrOls BIAMP SYSTEMS Designed in Australia N24138 Assembled in USA Model VO-4 YEL:in use/conductor GRN:link/act Control Outputs Control Inputs Audio Outputs Device ID CobraNet ® C NC NO C NC NO C NC NO C NC NO 3 4 10V PoE IEEE 802.3af...
Page 6
If other network traffic shares an Ethernet switch with the Vocia network, a managed switch should be used with separate VLANs. All Ethernet wiring is to be done using shielded CAT5, CAT5e, CAT6, or CAT7 cable. VO-4 BIAMP SYSTEMS Designed in Australia N24138...
VO-4 rear panel cOntrOls Control Outputs The Control Outputs, labeled 1 through 4, are isolated, voltage-free, software-configurable relay outputs. The individual pins are labeled as follows: 1. (C): the common/ground pin 2. (NC): normally closed (connected to C when relay is not energized) 3.
VO-4 installatiOn Installation The VO-4 requires one 1.75 inches (44.45mm) high and 19 inches (483mm) wide rack space with 10 inches (254mm) depth. mounting the unit using four screws with washers will prevent marring of the front panel. PVC or nylon washers are appropriate. Please install the unit away from heat sources, such as vents and radiators, and in rooms with adequate ventilation.
VO-4 specificatiOns Vocia Output 4 SPECIFICATIONS 20Hz to 20kHz + or – 1dB Frequency Response: Control Outputs Type: Form C Voltage free change over contact Max Operating Voltage: 125VAC, 60VDC THD + N (20Hz to 8kHz): <0.02% Max Switching Capacity: 37VA Min Operating Load: 10µA @ 10mV DC...
9. BIAMP Systems shall not be liable for special, indirect, incidental, or consequential damages, including lost profits or loss of use arising out of the purchase, sale, or use of the products, even if BiAmP Systems was advised of the possibility of such damages.