Jifon AquaHeat Jifon AquaHeat A groundwater heat pump User Manual User Manual Installation Manual, Planning Manual Three phase 400 V AquaHeat • AquaHeat Doc: AH-01 •...
Page 2
This manual contains copyright protected information which is the property of Jifon AB. No part of this document may be copied or forwarded electronically, or in any other way, without a prior written permission from Jifon AB. The same rule applies to images in the manual and translation to other languages.
Contents Introduction Mounting of the evaporator Shape Pipes Placement of the Heat Pump Module Safety Instructions Connecting to an Existing Heating System Introduction Installing and Connecting the Control Panel Placement of the Air Temperature Sensor Pressure Test Vacuum Drive User Manual Refrigerant Operation Start-up Temperature Setting...
Introduction Introduction Congratulations! When you chose the Jifon heat pump, you chose a heat pump system which is a more energy-saving concept than traditional heat pumps. Th e system examines a list of parameters to ensure that the operation always is machine-friendly and energy-effi cient.
If problems arise with the AquaHeat heat pump, refer to the Troubleshooting chapter before you contact Jifon. If you need a service engineer, only contact authorized service engineers. All adjustments, other than room temperature are strictly forbidden. All maintenance work must only be carried out by authorized personnel.
Page 6
Introduction Machine Signs Model: Serialno: Refrigerant: Amount: Safety relief pressure HP-side LP-side Made in Sweden CE - Sign High Voltage Sign NOTICE TO INSTALLER! • THIS THREE-PHASE UNIT IS ROTATION SENSITIVE • USE SERVICE GAGES WHEN STARTING • SWITCH ANY TWO COMPRESSOR POWER LEADS AT THE CONTACTOR TO CHANGE ROTATION DIRECTION REVERSE RUNNING...
Introduction Introduction System Description Th e system consists of a control panel (1), heat pump module (2) and a evaporator (3). Th e heat pump heats the house waterborne systems by extracting energy from ground- water. Th e control panel manages control of the heat pump and supplement heat source. Using an indoor sensor, it ensures that an even temperature is maintained regardless of weather conditions.
Page 8
Introduction Operation Two copper pipes are connected to the evaporator. One pipe transfers fl uid to the AquaHeat Th e other pipe transfers energy fi lled gas to the heat pump module. Energy is transferred to the buildings hydronic heating system by the heat pump module. Th e heated water is then pumped around the building.
User Manual User Manual Included Parts AquaHeat Aqua Heat consists of a PEM (polythene) tube with copper tubes inside which are rotated around a loop. Th is acts as an evaporator with natural regulation of the liquid and gas volume of the refrigerant in the system.
Page 10
User Manual Heat exchanger Compressor Junction box Vibration absorber High pressure sensor Low pressure sensor Flameproof insulation Safety Switch CE-Sign Drying filter On the top side of the heat pump module there are two pipes (infl ow and outfl ow) for the refrigerant and two pipes (infl...
Page 11
Th e air temperature sensor has to be placed where it is changed by the Jifon heating system of the room/house such as fl oor heating and radiators and not by local sources of heat such as lamps, stoves, and direct sunlight. Th e air temperature sensor should not be placed on external walls.
User Manual Temperature Setting Temperature Regulation Th e regulation of the temperature in the house is done with the digital MCX control. Th e factory default setting air temperature setpoint is 21°C. When the air temperature sensor measures a temperature that is 0.1°C below the control panel value the compressor is started with a delay of 500 seconds.
Page 13
Jifon AB or authorized personnel. Th e factory setting is 50°C and must only be changed by Jifon AB or authorized personnel. Th e compressor is automatically shut off at the setpoint value (50°C) to protect the compres- sor and it starts again when the water temperature is 5°C below the setpoint value.
User Manual Care and Maintenance Controls If the heat pump should stop functioning, consult the troubleshooting section of this manual. If the problem persists, contact your installation technician for further instructions and assist- ance. Defrosting of the AquaHeat Defrosting of the AquaHeat coil is done automatically. Change of Components NOTE! Change of components...
User Manual Troubleshooting Description Probable Cause Solution The house is not getting The settings for the control pa- Check the settings for the control warm nel are wrong panel (see Control Panel, page The additional heating is not Contact your installation techni- working cian The HP or LP is displayed...
User Manual Recycling and Dismantling NOTE! All current to the heat pump must be disconnected before dismantling can begin. When the heat pump is to be dismantled and recycled, follow these instructions: • Draining of the refrigerant must be performed by accredited personnel. •...
97/23/EC Tryckbärande anordning article 3.3 Manufacturer name, address, telephone and fax no: Tillverkarens namn, adress, telefon och faxnummer: Jifon AB Verkstadsgatan 1, SE-280 10 Sösdala, Sweden Telephone: +46(0)451-70 54 60, Fax: +46(0)451-600 12 Brand name or trademarke Fabrikatnamn eller varumärke...
Unpack the material and check to see that it has nothing missing or anything damaged due to transportation. Any damages due to transportation should be immediately reported to the transporter and to Jifon AB. Lifting/Unloading Consider the following when lifting/unloading the AquaHeat coil and the heat pump module: •...
Installation Manual Mounting of the Evaporator NOTE! Note that condensation may form around the evaporator The evaporator • We recommend that there is runoff potential (a drain) under the evaporator, whereby condensation may form • Control of water quality, see salt, iron and manganese, etc., high levels may damage the evaporator (copper) •...
(see page 21-22 for more information). Jifon recommends using fl exible connection hoses for vibration dampening when connecting the heat pump module to an existing heating system. Th e following applies when connecting water pipes to the heat pump module, regardless of model: •...
Page 21
Installation Manual JiControl The air temperature starts the heat pump when the temperature drops 0,1 degrees Additional heating is activated if the temperature falls 0,5 degrees under the set value Radiator Additional heating Floor heating Water in 1. Expansion vessel Heat bearer 2.
Page 22
Installation Manual JiControl The air temperature sensor starts the heat pump when the temperature drops 0,1 degrees Additional heating is activated if the temperature falls 0,5 degrees under the set value Radiator Heat pump Floor heating 1. Expansion vessel Water in 2.
It is also important that the air temperature sensor is placed in the room where it is aff ected by the Jifon heating system of the room/house, such as fl oor heating and radiators, and not by any local heat source such as lamps, stoves or direct sunlight.
Installation Manual Operation Start-up NOTE! To be able to quickly start the compressor, the setting on the control panel displays must be changed (see Delay Setting on page 25). In operation mode this is set to 500 seconds but can be set to 10 seconds during operation start-up or service.
Installation Manual Temperature Setting Temperature Regulation Th e regulation of the temperature in the house is carried out by the digital MCX control. Th e factory default setting air temperature setpoint is 21°C. When the air temperature sensor measures a temperature that is 0.1°C below the control panel value the compressor is started with a delay of 500 seconds.
Installation Manual Parameter list Main Menu Alarms Active Alarms Reset Alarms Login Password Parameters Regulation Setpoint Default U.M. Setpoint -40,0 150,0 21,0 °C Differential 1 50,0 Differential 2 50,0 High Water Set -99,9 99,9 50,0 °C High Water Diff 20,0 Confi...
Installation Manual Installation Checklist Serial Number Installation Date Installation Technicians Property address Pressure Test Passed Failed Vacuum Drive Passed Failed Additional Heating Electric Element Oil Boiler Gas Boiler Pellet Boiler District Heating _____________________ Heating System Radiators Air Heating Aggregate Supply Air Aggregate Floor Heating _____________________ AH-01...
Installation Manual Measurements and Connections (13kW-18kW) 2 3 4 Ø connection for outgoing water Ø connection for incoming water Ø connection for outgoing refrigerant Ø connection for incoming refrigerant Ø electrical connection Ø electrical connection Technical Data Model AquaHeat Model AquaHeat Unit 13kW 18kW...
Planning Manual Planning Manual Electricity Th e heat pump module shall always be connected to a permanent electrical installation. We defi ne a permanent electrical installation to be a connection to a power distribution grid. Transport and Storage Th e heat pump is delivered on europallets. If there is a delay before assembly and connection, consider the following: •...
Planning Manual Preparations The evaporator • We recommend that there is runoff potential (a drain) under the evaporator, whereby condensation may form. • Monitoring of water quality, see the salt, iron and manganese, etc., high levels may dam- age the evaporator (copper) •...
Page 34
Planning Manual Placement of the JiControl Th e installation of the control panel is to be carried out by authorised technician. Th e location of the control panel should be agreed with the client and engineer prior to the installation. •...
Jifon recommends installing pre-heating when heating domestic hot-water. Within the Jifon solution, pre-heating of domestic hot-water is preferred. A single-jacket and insulated water heater is installed in the house. Th e water entering the heater and its mixing valve have already been heated by the hydronic heating system of the house.
Page 36
A Better Climate with products from Jifon AB Jifon AB - Verkstadsgatan 1 - 280 10 SÖSDALA, Sweden Phone: +46-451 70 54 60 - Fax: +46-451 600 12 Internet: www.jifon.se - E-mail: kontor@jifon.se More From Less...