Gas Countertop Hot Plates/Cooktops Operating Instructions Before you begin, please read these instructions carefully to use this product correctly, to make the product perform ideally, and to avoid hazards. Models: ATHP-12-2/ ATHP-24-4 / ATHP-36-6...
Page 2
Dear customers and users: Thank you for purchasing our products. In order to be able to better use this product, please read these instructions carefully before any operation, and follow the guide, to avoid any unnecessary trouble during using. Please keep this instruction manual in a safe place for convenient reference and operation.
Gas Countertop Hot Plates/Cooktops The Installation, Operation and Maintenance Guide Contents 1. Safety Protection ……………………………………………………3 2. Brief Introduction……………………………………………………3 3. Manufacturer's Authority and Responsibility …………………3 4. Parameter Specifications……………………………………………4 5. Transport and Storage ………………………………………………6 6. Installation and Debugging…………………………………………6 7. Safety Notices and Precautions……………………………………8 8.
1. Safety Protection Please make sure that the operator is an authorized and licensed technician before you allow him/her to install and operate the products. Be sure to strictly follow this instruction guide during installation and using. The manufacturer is not responsible for any dangers or accidents caused by improper operation or maintenance.
Be repaired or changed by unauthorized technicians; Use the spare parts or accessories provided by non-manufacturers; Accidents caused by force majeure; Not strictly comply with related guide of this instruction by any reason. 4. Parameter Specifications 4.1、Outline Dimensions(in) ATHP-12-2 ATHP-24-4 - 4 -...
Page 6
Intake-tube Per BTU Total BTU Nozzle Model and control pressure B.T.U./ Species B.T.U./h method (in.W.C.) Natural 2 pieces 25,000 50,000 ATHP-12-2 Independent control L.P. Gas 25,000 50,000 Natural 4 pieces 25,000 100,000 ATHP-24-4 Independent control L.P. Gas 25,000 100,000 Natural...
5. Transport and Storage In the process of transportation, handle carefully and keep upright to prevent damage of the product packing. Wrapped equipment should not be in open air for a long time, and shall be placed in a well-ventilated and non-corrosive gases warehouse.
Page 8
Important: Installation and ventilation laws, and codes are very different, you should state and comply with all codes of the National Fire Protection Association Inc when it comes to requirements for installation of equipment; Screw 4 adjustable stainless steel legs in the tapping hole with four corners of the charbroiled bottom, ensure sufficient space for ventilation;...
●Unplug pressure gauge after you accomplish pressure testing, then install needle type pressure joint screw arbor. Important: must screw joint screw arbor, to prevent gas escape! 6.2、Debugging It’s very important to debug the new stove. Through the comprehensive system test of equipment, we can ensure function and safety performance of products.
Never change any other parts without authorization to this equipment, otherwise, may cause hazards, and the manufacturer has the right not to provide warranty service; Steel cutting producers used to manufacture with sharp edges. The manufacturer has dealt with these sharp edges during production, however, we insist the operator take care when in contact with this piece of equipment;...
Page 11
Install the matched cooking fume exhauster according as the local regulations over the char broiler; Make sure to keep the air natural circulation in the kitchen. 8.3、Turn off the valve Revolve the control valve knob clockwise to "0" (Fig.1), so that extinguish flame of the main burner, but the pilot light still works.
input), normal use without adjustment but only switching gas. Adjust only by authorized and licensed technicians. Fig.5 Fig.6 Fig.7 9. Cleaning and Maintenance Do not use any abrasive or flammable detergent to wipe; Do not hose down, immerse or pressure wash any part of the cooker, excluding the catch tray;...
<Table 2> Items Methods Times Wipe it with a soft cloth and mild Body daily detergent; Turn off valves when not in use; Control panel Wipe panel and control valve knob with daily mild detergent. Pull out catch tray from front body until the equipment cools down.
4.The pilot light and the main 4.Adjust fire’s distance is too far distance of them 5.Adjust the height 5.Flame is too low of the pilot light 1.Insufficient gas pressure 1.Contact the local in pipe gas supply dept. 2.Not match nozzle aperture with 2.Adjust nozzle Close gas and...
12. Accessories List <Table 5> Model ATHP-12-2 ATHP-24-4 ATHP-36-6 Name Adjustable 4 pieces 4 pieces 4 pieces steel legs Catch tray 1 piece 1 piece 1 piece pressure maintaining 1 piece 1 piece 1 piece valve A18 nozzle 2 piece...
Page 20
Our products have the advantages of good durability and low maintenance charge. But to update some components and necessary maintenance, can prolong life length of the products. Contact the dealer for assistance. In order to avoid confusion, please follow the format in figure 8 and table 4. - 19 -...