Naturela NHC-H42-2 User Manual

Electronic temperature regulator for three-phase electrical water heaters, with two heat exchangers and a remote control option

Advertisement

Quick Links

Electronic temperature regulator
for three-phase electrical water heaters,
An indicator
for working
electrical heater
NHC-H42 are a new generation built-in electronic temperature regulators, designed for
combined water heaters with up to three heat sources:
An electrical heater;
A solar collector;
A boiler.
The controller has a contrast LCD display, four control buttons and a LED indication for the
electrical heater. NHC-H42 has a built-in electronic temperature regulator to control a mono-phase
or three-phase electrical heater with accuracy of the measured temperature up to 1%, and two
precise differential temperature regulators directly running the circulation pumps on 220VAC
The first one of the temperature regulators is specialized to work with a solar collector and the
NHC-H42-2 Reference Manual ver 1.6
with two heat exchangers and
a remote control option
NHC-H42-2
software version 2.3
User manual
On/Off/Set
View/Enter
стр. 1 / 18

Advertisement

loading
Need help?

Need help?

Do you have a question about the NHC-H42-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Naturela NHC-H42-2

  • Page 1 1%, and two precise differential temperature regulators directly running the circulation pumps on 220VAC The first one of the temperature regulators is specialized to work with a solar collector and the NHC-H42-2 Reference Manual ver 1.6 стр. 1 / 18...
  • Page 2 Priority mode might be used. Thus, the circulation pump's turnings on and off depend only on the boiler's temperature. On this mode, if the boiler is hot enough, the building is heated, regardless of the water heater's temperature. NHC-H42-2 Reference Manual ver 1.6 стр. 2 / 18...
  • Page 3 The controller directly controls the circulation pumps of the external installations and turns on the three-phase electrical heater via three relays. Connection scheme of NHC-H42 to a three-phase water heater NHC-H42-2 Reference Manual ver 1.6 стр. 3 / 18...
  • Page 4 The battery keeps the time settings for maximum 18 hours, after that the clock turns off and needs to be set again. NHC-H42-2 Reference Manual ver 1.6 стр. 4 / 18...
  • Page 5 While in Settings mode, the display has a similar view: Title of the setting menu Editable parameters The parameter that is currently selected and is going to be edited, is blinking. NHC-H42-2 Reference Manual ver 1.6 стр. 5 / 18...
  • Page 6 Meanwhile, if the solar installation works, it will continue heating the water up and the electrical heater might not be used at all. Beside the temperature that should be reached while using electricity, there is a temperature • NHC-H42-2 Reference Manual ver 1.6 стр. 6 / 18...
  • Page 7 EL Eco Settings, Heater On off when the temperature in the bottom section of the water heater gets equal or NHC-H42-2 Reference Manual ver 1.6 стр. 7 / 18...
  • Page 8 When the water heater is on and the screen has the Design II view, pressing the F (On/Off/Set) button turns the water heater off, the screen's brightness gets decreased and the screen gets the NHC-H42-2 Reference Manual ver 1.6 стр. 8 / 18...
  • Page 9 ** diagrams for the consumed electricity and for the pump's work Day rate start time to calculate the consumed electricity Night rate start time to calculate the consumed electricity * Start of the first interval (timer) that allows the heater's work NHC-H42-2 Reference Manual ver 1.6 стр. 9 / 18...
  • Page 10 S3 E2 – A breakdown in the temperature sensor of the collector. It is on short circuit. ■ Only modes with electrical heating and boiler heating will work. In this case the NHC-H42-2 Reference Manual ver 1.6 стр. 10 / 18...
  • Page 11 A diagram for the active hours of the boiler's circulation pump, divided by hours for the current day. 50% for one hour means that the pump has been working for 30 minutes out of 60 possible. NHC-H42-2 Reference Manual ver 1.6 стр. 11 / 18...
  • Page 12 The menu EL Eco Setting is more appropriate for setting the temperature, because it allows regulating not only the temperature for turning the heater on, but also for turning it off. NHC-H42-2 Reference Manual ver 1.6 стр. 12 / 18...
  • Page 13 If the temperature difference between the collector and the water heater is more than Pump On, the pump turns on and works until the difference is less than Pump Off. NHC-H42-2 Reference Manual ver 1.6 стр. 13 / 18...
  • Page 14 If the water heater was on, after turning it off and then on again, it will be on the same mode with the same set temperature. NHC-H42-2 Reference Manual ver 1.6 стр. 14 / 18...
  • Page 15 If the clock is blinking, i.e. it is not set, you would have to do this first and proceed to System Setting after that Mind that if you deactivate the solar collector, this disables its safe modes for freezing and overheating too! NHC-H42-2 Reference Manual ver 1.6 стр. 15 / 18...
  • Page 16: Error Messages

    It activates if the collector's temperature is below 4°C. Preventing the tank's freezing. The electrical heater turns on if the temperature in the water • NHC-H42-2 Reference Manual ver 1.6 стр. 16 / 18...
  • Page 17 If the box is checked, the solar installation's pump works If the box is checked, the boiler installation's pump works NHC-H42-2 Reference Manual ver 1.6 стр. 17 / 18...
  • Page 18 • ▼ pressing the button pressing the F button saves the changes and forwards to the next parameter, if any, or • to “Water heater Off” mode. NHC-H42-2 Reference Manual ver 1.6 стр. 18 / 18...