Using Your Humidifier - MoistAir MA0600 Use And Care Manual

Tower humidifier 6 gallon output with digital readout
Table of Contents

Advertisement

Operating the Controls - continued
Speed Button
This humidifier is equipped with a
3-speed fan control. Initially depressing
the speed button will display the current
speed setting. Each push of the speed
button advances the mode through the
settings of (HIGH) F3, (MEDIUM) F2 and
(LOW) F1.
The selected setting is displayed on the
digital readout. The higher the setting,
the faster water is evaporated and
released into the air. F1 (LOW) is the
quietest setting and is provided for
conditions that do not require a rapid
evaporation rate.

Using Your Humidifier

Refill Display
For maximum run time both the bottle
and the base should be filled. When
both the bottle and the base are empty
the display alternates the room
humidity reading and "F" (FILL),
indicating that additional water is
required. Also at this time the unit will
automatically switch into DRY OUT
MODE and continue to run on the
lowest speed until the filter is dry.
Humidity Control
This button allows you to adjust
the humidity to suit your needs.
This humidifier will automatically
cycle on and off as required to
maintain the selected setting. The
readout displays both actual
(ROOM) and desired (SET)
humidity percentage (%) settings
when humidity control button is
pressed. The ROOM readout has
a range of 20% to 95%. If the
room humidity level is equal to or
less than 20% the display will
show a flashing 20.
The SET readout has a range of
25% to 65% and is adjusted in
increments of 5%. Initially
depressing the humidity button will
display the current humidity
setting. Each additional press of
the button increases the setting by
5%. A SET point of 65% operates
the humidifier continuously
regardless of the ROOM reading.
The humidistat that senses the
readings is located on the power
cord. Insure that it is free from
obstructions.
8
NOTE: During this time the room humidity level will continue to be monitored
and the humidifier will cycle the fan on and off until the filter is completely dry.
The fan will shut off leaving you with a dry humidifier that is less prone to mold
and mildew growth. If DRY OUT MODE is not desired, refill the humidifier with
water and the fan will return to the set speed.
NOTE: Fan automatically switches to lowest speed during DRY OUT MODE.
Check Filter Indicator
The ability of any humidifier to
efficiently supply humidity output
relies heavily on the condition of the
filter. As the filter loads with impurities
it gradually loses its wicking capability.
When this happens, moisture output is
reduced and the humidifier has to
work longer to satisfy the selected
setting. This humidifier has a check
filter reminder timed to appear after
720 hours of operation. When display
shows an alternating "CF" and "room
humidity" setting at 5 second intervals
it is a reminder to check the filter
.
condition
Humidistat
The humidistat located on the power cord senses the percentage of humidity in
the air. It causes the humidifier to cycle on and off to maintain the selected
humidity SET point. The fan will turn on if the "ROOM" reading falls 3% below
the SET point and will continue to run the humidifier until a reading of 1% above
the SET point is achieved. The fan will turn off until the ROOM reading falls 3%
below the SET point again.
NOTE
: Be sure that the humidistat, which is located on the power cord, is free
from obstruction and away from any hot air source.