  • Page 1 ZEROWIRE® G2 Advanced Wireless HD-Video Transmission System USER MANUAL E N G L I S H...
  • Page 3 © 2015 NDS Surgical Imaging. All rights reserved. Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. This document is subject to change without notice. NDS provides this information as reference only.
  • Page 5: Table Of Contents

    Section 5 Specifications ---------------------------------------------------------------------------------------- 16 Maximum EIPR Output Power of Test Frequency ------------------------------------------ 16 Supported Video Modes -------------------------------------------------------------------------- 17 ZeroWire G2 Accessory Kits by Display ------------------------------------------------------- 18 Cleaning Instructions ------------------------------------------------------------------------------- 19 Section 6 Electromagnetic Compatibility (EMC) Tables ----------------------------------------------- 20 Contact ---------------------------------------------------------------------------------------------- Back...
  • Page 6: Warnings And Cautions

    Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC. FCC Identification: UK2-SII-SK63102, UK2-SII-SK63101 Industry Canada: 6705A-SIISK63102, 6705A-SIISK63101 This product complies to the above standards only when used with an NDS supplied medical grade power supply. Model ZeroWire G2 Power Supply Ault MW172KB2400B02 or GlobTek GTM91120-3024-T3A AC Input 100 to 240 Volts at 50 to 60 Hz.
  • Page 7: Declarations Of Conformity

    NDS neither assumes nor authorizes any person to assume for it any other liabilities in conjunction with and/or related to the sale and/or use of its products. To ensure proper use, handling and care of NDS products, customers should consult the product specific literature, instruction manual, and/or labeling included with the product or otherwise available.
  • Page 9: About This Manual

    Overview The ZeroWire G2 System allows wireless delivery of video signals from the DVI or 3G-SDI output of an endoscopic camera processor or other video source to the DVI input of a video display. It operates as a 60Ghz-based wireless HD system in compliance with FCC (Part 15) rules governing the unlicensed 57-64 GHz band which is located in the millimeter-wave (mmW) portion of the electromagnetic spectrum.
  • Page 10: Noninterference Distance

    The listed devices on the following table have been tested to demonstrate the minimum safe distances for the ZeroWire G2 to be operating without any interference with each other. At any time, if the ZeroWire G2 is believed to be causing or getting the interference from those devices, simply move the devices away...
  • Page 11: Connector Panels

    Connector Panels ZeroWire G2 Transmitter DVI Input 3G - SDI Input USB ports are used for installing On / Off Power updates to the Transmitter or Switch Connector Receiver firmware, and not for use as a general purpose I/O port.
  • Page 12: Installation

    Installation Mounting Brackets: Refer to the ZeroWire G2 Accessory Kits by Display table on Page 18. Installation: (For Mounted Displays) Note: This installation requires two people: one to support the display, and one to perform the installation. Mounting Blade Replace the left-side mounting screws with two of the provided longer length mounting screws.
  • Page 13 Replace the right-hand screws with the provided screws and tighten all screws. With the back of the ZeroWire G2 Transmitter or Receiver module facing the front of the display, align the slot on the bottom of the module with the mounting blade, and push the module onto the mounting blade until the module is firmly seated.
  • Page 14: Power Options

    Power Options ZeroWire G2 Transmitters and Receivers used with a supported 32" or smaller NDS display can use an optional ‘Y’ adapter cable for powering the ZeroWire unit. The two types of ‘Y’ adapter cables are shown below. Where applicable, the appropriate Y-cable is included in the accessory kit (see page 18 to determine the correct accessory kit for the NDS display being used).
  • Page 15: Wiring Diagrams

    Wiring Diagrams ZeroWire G2 Transmitter Wiring Transmitter Black wires are 24 VDC. Blue wire is the DVI cable . Yellow wire is the optional 3G-SDI cable. Output Output Power to Display DVI Video Source Power to Transmitter ZeroWire G2 Receiver Wiring Receiver Black wires are 24 VDC.
  • Page 16: Setup

    Setup Linking the Transmitter and Receiver Prior to placing the ZeroWire G2 system in service, the Transmitter and Receiver pair must be linked. Once a Transmitter and Receiver pair is linked, they remain linked until the Transmitter is explicitly linked to another Receiver or the Receiver is explicitly linked to another Transmitter.
  • Page 17: Typical Installation

    Performance Performance: ZeroWire G2 HD Wireless Video System is intended and optimized for use in surgical or procedure rooms. Use outside of a clinical environment is not recommended. The following steps will help you to achieve optimal performance of the ZeroWire G2 system: 1.
  • Page 18: Positioning And Orientation

    Positioning and Orientation Due to the shape of the antenna’s signal field, both Transmitter and Receiver units should be installed so they are aligned vertically and horizontally within ±10°. Vertical Alignment: Vertical alignment should be within ±10° of vertical. Horizontal Alignment: Horizontal alignment should be within ±10°...
  • Page 19 Transmitter and Receiver front edges parallel and facing each other. Separation: ZeroWire G2 operates correctly with a Transmitter and Receiver separation of up to 30 feet (9.1 m). However, in the case of most OR environments, best results are achieved with a Transmitter and Receiver separation distance of up to 8 feet (2.4 m).
  • Page 20: Non Line Of Sight Operation

    If an object must obstruct the line-of-sight, the best option is to position it half way between the Transmitter and the Receiver. OR rooms whose walls and/or ceiling are constructed with metal sheets may reduce ZeroWire G2 performance. This condition possibly can be mitigated by moving the Transmitter and Receiver closer to each other, setting their line-of-sight to 0 degrees (see page 10), and ensuring that there are no obstructions between the Transmitter and the Receiver.
  • Page 21: Avoiding Co-Channel Interference

    2. A maximum of two ZeroWire G2 systems may be operated in the same room. The transmitters and receivers should be separated by at least 3 feet (1 m) within the room. 3. Groups of two ZeroWire G2 systems may be set in multiple rooms, providing the rooms are spaced at least 25 feet (7.6 m) apart.
  • Page 22: Signal Strength And Osd Diagnostic Messages

    Signal Strength and On Screen Diagnostic (OSD) Messages When a receiver is connected to a monitor, self-explanatory diagnostic messages are displayed in the lower left corner of the screen to inform the user of the receiver’s current status. The messages will be displayed for 15 seconds, with the exception of “No transmitter found”...
  • Page 23: Troubleshooting

    'Y' Cable: If you are using the ‘Y’ cable to supply power to the unit, confirm that it is connected to an NDS 24VDC power supply and that the power supply is energized. Stand Alone Power Supply: If the stand alone power supply is being used confirm that it is fully inserted into the wall socket.
  • Page 24: Specifications

    Specifications Wireless Signal Type 60 Ghz Wireless HD band (WiHD) Frequency Band 57 - 64 GHz Video Inputs (Tx) DVI-D, 3G-SDI Video Outputs (Rx) DVI-D Video Compression None 3D Video Support DVI-D Interleaved (Line-by-Line) HIPAA Support 256 bit AES Encryp on System Latency <...
  • Page 25: Supported Video Modes

    Supported Video Modes Frame Horizontal Vertical Horizontal Vertical Format Rate (Hz) Active Pixels Active Pixels Total Pixels Total Pixels 1080p 1920 1080 2200 1125 1080p 1920 1080 2640 1125 1080i 1920 1080 2200 1080i 1920 1080 2640 720p 1280 1650 720p 1280 1980...
  • Page 26: Zerowire G2 Accessory Kits By Display

    ZeroWire G2 Accessory Kits by Display ZeroWire G2 Accessory Kit Pair: (Transmi er Single: (Transmi er Display NDS Part # and Receiver) or Receiver) EndoVue 24" (Standard) 90K0010 90Z0152 90Z0153 China Model 90K0011 Discon nued Model 90K0004 Radiance Full MMI 24" (Standard)
  • Page 27: Cleaning Instructions

    Ammonia-based glass cleaner Acceptable Disinfecting Material: Ethanol 80 % by volume *Note: The acceptable cleaning and disinfecting materials listed above have been tested on NDS products and, when used as directed, do not harm the product’s finish and or its plastic components.
  • Page 28: Electromagnetic Compatibility (Emc) Tables

    12. We recommend that the system be thoroughly tested prior to using it in any surgical procedures. Do not use power supplies or cable accessories with the ZeroWire G2 other than those specified in this manual. Excessive leakage currents, elevated electromagnetic emissions, or insufficient interference immunity may occur.
  • Page 29 EMC Tables Guidance and manufacturer’s declaration – electromagnetic emissions The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Emissions Compliance Electromagnetic environment-- guidance The product uses RF energy only for its internal function.
  • Page 30: Contact

    EMC Tables Guidance and manufacturer’s declaration 211; electromagnetic immunity The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance...
  • Page 31 EMC Tables Guidance and manufacturer’s declaration – electromagnetic immunity The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment –...
  • Page 32 EMC Tables Recommended separation distances between portable and mobile RF communications equipment and the product The product is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the product can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the product as recommended below, according to the maximum output power of the communications equipment.
  • Page 34 Corporate Headquarters San Jose, CA USA 408 776 0085 info@ndssi.com Europe The Netherlands + 31 180 63 43 56 info-EMEA@ndssi.com Asia Pacific Japan +81 3 5753 2466 info@ndssi.jp 60G0571 Rev B 10 November 2015...