Minipuls C200 Before use We are pleased you have chosen a broncolor Minipuls C200 which is a high-quality product in every respect. If used properly, it will render you many years of good service. Please read all the information contained in these operating instructions carefully.
10 min.! • broncolor flash light systems should only be equipped with original broncolor flash tubes, original broncolor combustible and packing material, original broncolor accessories, and also original broncolor spare parts! •...
Page 4
protected from wetness, condensation, from dripping and splash water, humidity, dirt, sand, metal chips and exposure to dust! • Protect the flash light equipment from electromagnetic fields, shock and vibration! • Protect the flash light equipment from heat and frost! If the monolight freezes continuous loss of power output and serious technical damage can result! •...
Page 5
Incorrect reassembly can cause electric shock when the appliance is used subsequently! Shipping instructions Minipuls C200: Use original broncolor packing for the transport of the monolight! Before shipping flash tubes, halogen lamp and protection glass pack them with our protective pack material (foam plastic and transport cap). If the...
2. Start up Mains voltage The monolight Minipuls C200 is optimised for mains voltage and is not switchable. Nevertheless the 200-240 V version can be operated on a mains voltage of 120 V / 60 Hz with the following restrictions: a) a modelling lamp 120 V / 150 W must be used b) the charging time increases to 6.9 s...
To ensure an optimal colour temperature, this monolight must be used with a UV-coated protecting glass. For your safety, only original broncolor flash tubes must be utilised. For safety reasons, never operate a unit without a protecting glass in place.
When inserting, ensure that the halogen lamp is fully pushed back in. When mounting the protecting glass make sure that the retaining spring of the Minipuls C200 does not coincide with the notches of the protecting glass edge. 6. Fuse The fuse (5) is located on the rear of the unit.
The enclosed locking pin has to be screwed into the lower part of the stand ® adapter so it can be hung from a broncolor bolt; this is not required for stand mounting.
This “test” key (1) allows manual release of the Minipuls C200. 12. Accessories The Pulso bayonet system allows you to use the full line of broncolor reflectors. For a complete summary, please consult the broncolor system catalogue, "Be Creative with Light. And with System".
Technical data Minipuls C200 Flash energy 1500 J F-stop at distance of 2 m, 100 ISO, reflector P70 Flash duration t 0.1 1/250 s t 0.5 1/1000 s Charging time 0.6 - 2.4 s (for 100 % of selected energy)
35228.00 16. Guarantee All broncolor power packs, lamps, monolights and accessories have a high quality standard. We offer a 2-year factory guarantee from the date of purchase (for the first owner) on the aforementioned units, except for flash tubes, halogen lamps, protecting glasses, cable, batteries, rechargeable batteries and textiles.