Precautions at the time of the side B(back) service of digital unit.
1. Remove only SC2001 of the FFC for connection between Digital unit(SC2001) and Analog unit(SC3403), and
connect the extended cable (QCNW-A556WJZZ) for service.
2. Remove only P2004 of the Connecting Cord for connection between Digita unit(P2004) and Analog unit(P3702),
and connect the extended cable (QCNW-A552WJZZ) for service.
3. Remove the FFC for connection between Digita unit(SC1203) and LCD panel unit, and connect the extended
cable (QCNW-A553WJZZ) for service.
4. Remove the FFC for connection between Digita unit(SC1202) and LCD panel unit, and connect the extended
cable (QCNW-A556WJZZ) for service.
5. Remove the FFC for connection between Digita unit(SC1201) and LCD panel unit, and connect the extended
cable (QCNW-A555WJZZ) for service.
6. Remove the R/C, LED unit.
6-1. Remove a lead from a wire holder.
6-2. Remove the R/C, LED unit fixing screws(2 pcs.).
7. Remove the main unit fixing screws(3 pcs.), a substrate is reversed.
Digital PWB
(Side B)
4 5
SC1202
SC1202
SC1202
SC1201
Digital
Digital
Digital
SC1203
SC1203
SC1203
PWB
PWB
PWB
3
P2004
P2003
SC2001
SC2001
SC2001
2
Analog
PWB
P3503
P3601
P3500
P3500
P3500
R/C, LED PWB
6-2
13
Inverter-A
P6705
P6705
P6705
PWB
1
P3703
SC3403
SC3403
SC3403
P3702
P3504
P3504
P3704
P3704
P3602
P3602
P3602
Inverter-B
PWB
P6706
P6706
P6706
6-1
Wire Holder