XL-40H/50H
IC801 VHiTA2109F/-1:Servo Pre Amp. (TA2109F)
Pin No.
Terminal Name
1
VCC
2
FNI
3
FPI
4
TPI
5
TNI
6
MDI
7
LDO
8
SEL
9
TEB
10
2VRO
11
TEN
12
TEO
13
SBAD
14
FEO
15
FEN
16
VRO
17
RFRP
18
RFIS
19
RFGO
20
RFGC
21
AGCI
22
RFO
23
GND
24
RFN
Input/Output
Power voltage terminal
Input
Main beam amp input terminal
Input
Main beam amp input terminal
Input
Sub-beam amp input terminal
Input
Sub-beam amp input terminal
Input
Monitor photodiode amp input terminal
Output
Laser diode amp output terminal
Input
Laser diode control signal input and APC circuit ON/OFF signal input terminal
Input
Tracking error balance adjustment signal input terminal
To be controlled by 3-value PWM signal. (PWM carrier = 88.2 kHz)
Output
Standard voltage (2VR) output terminal. When Vcc = 5V, 2VR = 4.2V.
Input
Tracking error signal generation amp reversed phase input terminal
Output
Tracking error signal generation amp output terminal
Output
Sub-beam addition signal output terminal
Output
Focus error signal generation amp output terminal
Input
Focus error signal generation amp reversed phase input terminal
Output
Standard voltage (VR) output terminal. When Vcc = 5V, VR = 2.1V.
Output
Track count signal generation amp output terminal
Input
RFRP detection circuit input terminal
Output
RF signal output terminal
Input
RF amplitude adjustment control signal input terminal
The amplitude of RF signal can be controlled by using the 3-value PWM signal (PWM
carrier = 88.2 kHz) which is output from the RFGC terminal of TC9432F.
Input
RF signal amplitude adjustment amp input terminal
Output
RF signal generation amp output terminal
GND terminal
Input
RF reversed phase input terminal
Function
– 44 –