Quick Installation Guide - DDP3
To install the unit, create a cut-out in your countertop following the dimensions
This cooktop must be installed in
accordance with pertaining local
building, trade, fire protection and
electrical codes. If local codes do
not exist, then installation must
be
done
in
accordance
federal codes.
The cooktop is to be connected -
hard-wired - to the electrical power
supply
inside
a
client-supplied
junction
box
which
installed inside the cabinet below the
unit.
The
unit
must
grounded.
This cooktop is to be installed under
a ventilation hood or a downdraft
ventilation system.
Operating voltage ... 220 V~ 60 Hz
Total power ... 7600 W
Connect to ... 220 V, 60 Hz, 2 Pole+G,
40 A supply
(3 wire #8 AWG)
Cabinet Above
Cross
Section
Minimum
Clearance
Requirements
DDP-3
Cabinet Below
given on the drawing and the table below.
with
should
be
be
properly
Clearance
You should keep:
- Above the unit to any combustible surface - e.g. cabinet
above the unit:
- Below the unit - between the bottom of the unit and any
horizontal partition inside your cabinet: minimum clearance
of 50 mm (2").
885 Don Mills Road, Suite 207
NEW
FOR
2006
Cooktop and
Cut-out Sizes
Cut-out Size
Cooktop Box Size
Cooktop Rim Size
*This dimension includes clearance underneath the unit of 50 mm [2"]
minimum clearance of 750 mm (30");
Diva de Provence
Toronto,Ontario
M3C 1V9
C a n a d a
Tel: (416) 256-2646
Fax: (416) 256-7121
Width
Depth
565 mm
500 mm
[22 1/4"]
[19 11/16"]
558 mm
492 mm
[22"]
[19 3/8"]
598 mm
532 mm
[23 9/16""]
[20 15/16"]
Thickness
100 mm*
[4"]*
50 mm
[2"]
6 mm
[1/4"]