Main Screen - Lavry 3000S Operation Manual

Digital optimizer 96khz
Table of Contents

Advertisement

Operations Manual

Main Screen

The top line consists of:
IN:
Indicates input signal information
PRO
or CON (professional or consumer format)
44
or 48 (input frequency indication embedded in the input format)
44100
input frequency measurement to 1 Hz
CCITT
or 50/15uS, NO-EMPH or NOT-INDicated emphasis indication
The bottom line consists of:
OUT:
Indicates output signal information
PRO
or CON (professional or consumer format)
or 48 (output frequency indication embedded in the output format)
44
BYPASS
output operating mode. Possible output frequency or sync modes:
• BYPASS MODE
STRAIGHT-THROUGH MODE, OUTPUT FQ = INPUT FQ 40-100K
• 44.1k BYPASS
JITTER ATTENUATION MODE, OUTPUT FQ = INPUT FQ
• 48.0k BYPASS
JITTER ATTENUATION MODE, OUTPUT FQ = INPUT FQ
• 44.1 kHz XTAL
INTERNAL CRYSTAL CONTROLS OUTPUT FREQ., SAMPLE-RATE-CONVERSION
• 48.0 kHz XTAL
INTERNAL CRYSTAL CONTROLS OUTPUT FREQ., SAMPLE-RATE-CONVERSION
• AES LOCK 44.1
44.1K +-100 PPM LOCKS OUTPUT FREQUENCY TO SYNC INPUT
• AES LOCK 48.0
48.0K +-100 PPM LOCKS OUTPUT FREQUENCY TO SYNC INPUT
• AES WIDE LOCK
40K-50K WIDE LOCKS OUTPUT FREQUENCY TO SYNC INPUT
• WC LOCK 44.1
44.1K +-100 PPM LOCKS OUTPUT FREQUENCY TO SYNC WORD CLOCK INPUT
• WC LOCK 48.0
48.0K +-100 PPM LOCKS OUTPUT FREQUENCY TO SYNC WORD CLOCK INPUT
• WC WIDE LOCK
40K-50K WIDE LOCKS OUTPUT FREQUENCY TO SYNC WORD CLOCK INPUT
• 88.2 kHz XTAL
INTERNAL CRYSTAL CONTROLS OUTPUT FREQ., SAMPLE-RATE-CONVERSION
• 96.0 kHz XTAL
INTERNAL CRYSTAL CONTROLS OUTPUT FREQ., SAMPLE-RATE-CONVERSION
• 24 Bit ENCODE
ENCODES 24 BIT DATA INTO TWO HIGH-SPEED 16 BIT WORDS
• 24 Bit DECODE
4
IN:PRO 44
44100 50/15uS
OUT:CON 44
BYPASS MODE
44.1K +-100 PPM
48.0K +-100 PPM
LE3000S

Advertisement

Table of Contents
loading