Sanyo PLC-XU86 Service Manual page 33

Hide thumbs Also See for PLC-XU86:
Table of Contents

Advertisement

Electrical Adjustments
Item No.
NAME
48
NOR_VALU_FAN2_MIN
49
NOR_VALU_FAN2_MAX
50
ECO_TEMP_FAN1_MIN
51
ECO_TEMP_FAN1_MAX
52
ECOTEMP_FAN2_MIN
53
ECO_TEMP_FAN2_MAX
54
ECO_VALU_FAN1_MIN
55
ECO_VALU_FAN1_MAX
56
ECO_VALU_FAN2_MIN
57
ECO_VALU_FAN2_MAX
58
HINOR_TEMP_FAN1_MIN
59
HINOR_TEMP_FAN1_MAX
60
HINOR_TEMP_FAN2_MIN
61
HINOR_TEMP_FAN2_MAX
62
HINOR_VALU_FAN1_MIN
63
HINOR_VALU_FAN1_MAX
64
HINOR_VALU_FAN2_MIN
65
HINOR_VALU_FAN2_MAX
66
HIECO_TEMP_FAN1_MIN
67
HIECO_TEMP_FAN1_MAX
68
HIECOTEMP_FAN2_MIN
69
HIECO_TEMP_FAN2_MAX
70
HIECO_VALU_FAN1_MIN
71
HIECO_VALU_FAN1_MAX
72
HIECO_VALU_FAN2_MIN
73
HIECO_VALU_FAN2_MAX
74
CLNOR_TEMP_FAN1_MIN
75
ClNOR_TEMP_FAN1_MAX
76
CLNOR_TEMP_FAN2_MIN
77
CLNOR_TEMP_FAN2_MAX
78
CLNOR_VALU_FAN1_MIN
79
CLNOR_VALU_FAN1_MAX
80
CLNOR_VALU_FAN2_MIN
81
CLNOR_VALU_FAN2_MAX
82
CLECO_TEMP_FAN1_MIN
83
CLECO_TEMP_FAN1_MAX
84
CLECOTEMP_FAN2_MIN
85
CLECO_TEMP_FAN2_MAX
86
CLECO_VALU_FAN1_MIN
87
CLECO_VALU_FAN1_MAX
88
CLECO_VALU_FAN2_MIN
89
CLECO_VALU_FAN2_MAX
90
FAN_1_AUTO_ADJ
91
FAN_2_AUTO_ADJ
92
FACTORY_STD_FAN_VOL_MIN
93
FACTORY_STD_FAN_VOL_MAX
94
FAN1_ADJUST_VOLT_MIN
95
FAN1_ADJUST_VOLT_MAX
96
FAN2_ADJUST_VOLT_MIN
97
FAN2_ADJUST_VOLT_MAX
TEMP_ERROR_DETECT_MAX_
98
TIMES
99
FAN_1_MIN_VOL_LAMP_DIFF
100
FAN_2_MIN_VOL_LAMP_DIFF
101
LAMP_VOL_BORDER_LINE
102
LAMP_VOL
103
Dimmer Voltage Change Cycle
104
Dimmer Avarage Check Period
105
Dimmer Voltage Change Rate
106
Dimmer Average
107
Last Voltage Difference
108
Voltage Difference Goal
109
Fan Control TempDiff Normal
110
Fan Control TempDiff Eco
111
Fan Contro TempDiff HighLand Normal PW186
112
Fan Control TempDiff HiLand Eco
113
Fan Control TempDiff Ceiling Normal PW186
114
Fan Control TempDiff Ceiling Eco
115
Fan Control Temp UpTime Normal
116
Fan Control Temp UpTime Eco
117
Fan Contol Temp UpTime HighLand Normal
118
Fan Control Temp UpTime highLand Eco
119
Fan Contol Temp UpTime Celing Normal
120
Fan Contol Temp UpTime Celing Eco
121
Standby Cooling Temp Check Cycle
122
Standby Cooling Start Threshold Temp
123
Standby Cooling Disable/Enable
Group 200
Auto Calibration
0
Execute Calibration
1
Loop Count
XGA
Device
Component
PC/DVI/HDCP
HDTV
480p
M62398FP
81
M62398FP
132
PW186
47
PW186
50
PW186
47
PW186
50
PW186
52
PW186
115
PW186
65
PW186
89
PW186
48
PW186
48
PW186
48
PW186
48
M62398FP
135
M62398FP
135
M62398FP
135
M62398FP
135
PW186
48
PW186
48
PW186
48
PW186
48
M62398FP
120
M62398FP
120
M62398FP
91
M62398FP
91
PW186
47
PW186
50
PW186
41
PW186
53
M62398FP
68
M62398FP
135
M62398FP
80
M62398FP
132
PW186
47
PW186
50
PW186
47
PW186
50
M62398FP
52
M62398FP
115
M62398FP
65
M62398FP
89
PW186
0
PW186
0
PW186
52
PW186
135
M62398FP
15
M62398FP
203
M62398FP
15
M62398FP
203
5
0
0
70
-
3
10
1
-
-
-
PW186
0
PW186
0
0
PW186
0
0
PW186
0
PW186
0
PW186
0
PW186
0
PW186
0
PW186
0
PW186
0
PW186
5
PW186
54
PW186
1
PW186
0
PW186
3
Range Description
Video
480i
NTSC
PAL
0-255
FAN2 Control Min at Normal
FAN2 Control Max at Normal
FAN1 Control start temp.at Eco
FAN1 Control end temp. at Eco
0-255
FAN2 Control start temp.at Eco
FAN2 Control end temp. at Eco
FAN1 Control Min at Eco
FAN1 Control Max at Eco
0-255
FAN2 Control Min at Eco
FAN2 Control Max at Eco
FAN1 Control start temp.at Highland Normal
FAN1 Control end temp. at Highland Normal
0-255
FAN2 Control start temp.at Highland Normal
FAN2 Control end temp. at Highland Normal
FAN1 Control Min at Highland Nromal (0:0V, 255:25.5V)
FAN1 Control Max at Highland Normal
0-255
FAN2 Control Min at Highland Normal
FAN2 Control Max at Highland Normal
FAN1 Control start temp.at Highland Eco
FAN1 Control end temp. at Highland Eco
0-255
FAN2 Control start temp.at Highland Eco
FAN2 Control end temp. at Highland Eco
FAN1 Control Min at Highland Eco
FAN1 Control Max at Highland Eco
0-255
FAN2 Control Min at Highland Eco
FAN2 Control Max at Highland Eco
FAN1 Control start temp.at Ceiling Normal
FAN1 Control end temp. at Ceiling Normal
0-255
FAN2 Control start temp.at Ceiling Normal
FAN2 Control end temp. at Ceiling Normal
FAN1 Control Min at Ceiling Nromal (0:0V, 255:25.5V)
FAN1 Control Max at Ceiling Normal
0-255
FAN2 Control Min at Ceiling Normal
FAN2 Control Max at Ceiling Normal
FAN1 Control start temp.at Ceiling Eco
FAN1 Control end temp. at Ceiling Eco
0-255
FAN2 Control start temp.at Ceiling Eco
FAN2 Control end temp. at Ceiling Eco
FAN1 Control Min at Ceiling Eco
FAN1 Control Max at Ceiling Eco
0~255
FAN2 Control Min at Ceiling Eco
FAN2 Control Max at Ceiling Eco
0-1
0: OFF(Manual) 1:ON(Auto)
0-1
0: OFF(Manual) 1:ON(Auto)
0-255
For Factory
0-255
For Factory
For Factory
For Factory
0~255
For Factory
For Factory
1-9
Detecting times for Temp Error
0-20
0-20
30-90
0-255
Present Lamp Voltage
Change cycle of voltage at Dimmer
Measurement time of Dimmer average
Voltage change rate ta Dimmer
Dimmer average
Last voltage difference
Target voltage difference at Dimmer
0-10
Fan control temp. augment temp. Normal
0-10
Fan control temp. augment temp. Eco
0-10
Fan control temp. augment temp. HighLand Normal
0-10
Fan control temp. augment temp. HighLand Eco
0-10
Fan control temp. augment temp. Ceiling Normal
0-10
Fan control temp. augment temp. Ceiling Eco
0-5
Fan control temp. augment time Normal
0-5
Fan control temp. augment time Eco
0-5
Fan control temp. augment time HighLand Normal
0-5
Fan control temp. augment time HighLand Eco
0-5
Fan control temp. augment time Ceiling Normal
0-5
Fan control temp. augment time Ceiling Eco
1-30
Room temp sensor check cycle at standby cooling for MCI
0-100
Standby cooling starting temp for MCI
0-1
Standby cooling On/Off for MCI 0: OFF, 1: ON
0 - 255 Auto executiong when value changes
1 - 30
Loop times of Auto Calibration
-33-