Technical Data - Rinnai RHFE-1004FA Owner's Operation And Installation Manual

Hide thumbs Also See for RHFE-1004FA:
Table of Contents

Advertisement

WEIGHT
DIMENSIONS
Width: 36 5/8"
90 Lbs.
Height: 26 3/8"
Depth: 12 3/8"
Burner Orifices:
PARTS No.
HI
1004F-2031-2-1.80
LOW
1004F-2036-2-1.95
GAS
MODEL
TYPE
RHFE-1004FA-N
NG
RHFE-1004FA-P
LPG
GAS SUPPLY PRESSURE
NATURAL
5.0"W.C.
MINIMUM
MAXIMUM
10.5"W.C.
The minimum inlet gas supply pressures is for the purpose of input adjustment.
Heaters may be converted from one gas to another using Rinnai conversion kits.

TECHNICAL DATA

INPUT
NG
LOW
10,500 10,500
HIGH
38,400 36,500
NG
QTY'
2
1004F-2031-1-0.95
1
1004F-2036-1-1.20
GAS CONVERSION SPECIFICATIONS
DAMPER
DIAMETER OF
ORIFICE(mm)
A-DJUSTMENT
HI
LOW
FRONT
1.80
1.95
7/10
0.95
1.20
10/10
PROPANE
11.0"W.C.
13.0"W.C.
GAS RATE (BTU/h)
OUTPUT
LP
LOW
HIGH
30,720 29,200
LPG
PARTS No.
QTY'
2
1
MANIFOLD DIFFERENTAL
PRESSURE (W.C.)
RIGHT
LEFT
10/10
10/10
3.7"W.C.
10/10
10/10
10.1"W.C.
– 56 –
NG
LP
8,400
8,400
HI
LO
2.0"W.C.
4.3"W.C.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents