MW > yellow ; PIR > green; Alarm > red Operating temperature Auto compensation Cover color Art.9452 -> white - Art. 9454 ->brown Dimension 37 x 125 x 40m WARNING!!!! : To avoid the risk of damaging the product, never touch the PIR sensor with hands. Use a clean...
GENERAL DESCRIPTION Remove screw plastic protection, in the upper side of detector, using a screw driver. alarm shop ANGULAR BRACKET WALL MOUNTING Staffa di montaggio a parete Staffa di montaggio angolare reversibile Angular reversible mounting bracket Wall mounting bracket...
Page 4
WIRING Clamp description and purpose : = Positive 12Vcc. GND = GND ( negative) AMK = Antimasking Output N.C. = TAMPER (N.C.) MEM = Inhibition input and alarm memory enabling (positive) = Alarm output N.C. LED indicator LD4 = Red Led (alarm) LD5 = Yellow Led (microwave) LD6 = Green Led (IR) Trimmer...
Lateral view Top view alarm shop LED indicator MEM input: In case of alarm or masking attempt, a positive signal on this clamp shows the following events: LIGHTED ON FLASHING IR detection (no GREEN LED ///////////////// alarm) MW detection YELLOW LED ///////////////// (no alarm) RED + GREEN LED...
N.B. In case both masking and alarm condition occur, first LED will light on, then they will start flashing. GENERAL INSTALLATION GUIDE Perimeter protection alarm shop Windows protection Windows and door protection...
Installation To avoid troubles on the detector, it is necessary to check what follows: When the detector is powered on, LED indicator will flash alternatively (stabilization time). After that GREEN LED will flash fast and in the end YELLOW LED will flash fast. GREEN LED flashing fast means that detector is acknowledging environmental conditions necessary for “Beam antimask”...
DETECTION OPTIONS • Mw antimask When this function is enabled, AMK output activates if an obstacle remains in front of detector about 25sec. • IR antimask When this function is enabled, AMK output activates if an obstacle remains in front of detector. A IR active signal will be checked out to verify this condition. IMPORTANT NOTICE: We suggest to do not activate “Mw Antimask”...