INV-430J/PE
Finger Pulse Oximeter
User Manual
Distributed by:
Innovo Groups
406 Sterling Street, Building 2
Camphill, PA, 17011
Innovo Groups
Phone: +1-858-888-9781
406 Sterling Street, Building 2
cs@innovogroups.com
Camphill, PA, 17011
http://www.innovogroups.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INV-430J/PE and is the answer not in the manual?

Questions and answers

Summary of Contents for Innovo INV-430J/PE

  • Page 1 INV-430J/PE Finger Pulse Oximeter User Manual Distributed by: Innovo Groups 406 Sterling Street, Building 2 Camphill, PA, 17011 Innovo Groups Phone: +1-858-888-9781 406 Sterling Street, Building 2 cs@innovogroups.com Camphill, PA, 17011 http://www.innovogroups.com...
  • Page 2 Storage and Transportation Copyright © Innovo Groups 2015. All rights reserved. Innovo Groups owns and reserves all of the rights comprised in the copyright of this document. No part of this document may be changed, excerpted, copied, reproduced, or imitated in any form or by any means without prior written consent of Innovo Groups.
  • Page 3: Table Of Contents

    2.3 Product Features ............ 10 Running mode: continuous working 2.4 Limitations .............. 11 Waterproof grade: IP22 2.5 Innovative features of the INV-430J/PE ....12 Chapter 3 Product Structure Parameter Settings and Operation Steps................... 13 3.1 Schematic Structural Diagram ......... 13...
  • Page 4 6. Technical parameters 3.3 Parameter Settings ..........14 3.4 Operation Steps ............19 Parameter Value Chapter 4 Cleaning and Disinfection ........25 Oxygen Display 35% to 100% saturation 4.1 Cleaning ..............25 range Pulse rate 25 bpm to 250 bpm 4.2 Disinfection .............
  • Page 5: Letter To Users

    5. Default values and conditions of alert Letter to Users Thank you for choosing our Innovo INV-430J/PE Finger Pulse Parameter Value Oximeter. By listening to our customers and applying some Upper limit: 100 simple technological innovations, you will come to see that the...
  • Page 6: Standard Packing List

    Standard Packing List Chapter 6 Technical Description and Safety Type Pulse oximeter………………………….1 PCS Technical Specifications AAA Battery……………………………..2 PCS 1. Dimensions: 62.0 mm (Width) × 37.0 mm (Depth) × 32.0 mm Lanyard………………………………….1 PCS (Height) Silicon Cover……………………………1 PCS Weight: 42.5 g (including the height of the two AAA dry User Manual…………………………….1PCS batteries) 2.
  • Page 7 People who need and pulse rate measurements because of a medical condition should not use the INV-430J/PE and should consult with their physician. For details about clinical limitations and contraindications, ...
  • Page 8 The following factors may affect the accuracy of the Symptom Possible Cause Solution measurement: ◆ The Oximeter is used in an environment involving 1. The finger is not 1. Insert the displayed placed properly finger again. high-frequency devices, such as high-frequency value of the between the electric knives and CT apparatuses.
  • Page 9: Warnings

    Fault Symptoms, Causes, and Solutions Warnings Warning: Do not use the Oximeter in an environment with any flammable gases, flammable anesthetic, or other flammable substances. Symptom Possible Cause Solution 1. The finger is 1. Place the finger Warning: Keep unit and lanyard away from children as Oximeter not placed at the correct...
  • Page 10 Chapter 5 Maintenance and Troubleshooting Warning: Do not use the Oximeter in an MRI or CT environment. Maintenance  Remove the batteries from the battery slot and properly store them if you do not plan to use the Oximeter for a Caution: Do not operate the Oximeter if it is wet.
  • Page 11: Symbol

    Symbol Attention: Do not allow liquid to flow into the instrument during cleaning. Symbol Meaning Attention: Do not immerse any part of the instrument into any liquid. BF-type application part Disinfection Before measurement with the instrument, wipe the silicon finger Caution: Please see this manual.
  • Page 12 Chapter 4 Cleaning and Disinfection Symbol Meaning Cleaning Ensure that the appearance of the instrument is clean. To clean the instrument, power off and remove the batteries first. Then Please read the manual carefully. clean the outer surface of the instrument (including the OLED screen) using a piece of dry soft cloth dipped with 75% medical When end users abandon this product, alcohol.
  • Page 13: Chapter 2 About This Product

    Chapter 2 About This Product Overview stands for peripheral capillary oxygen saturation. Oxygen saturation is defined as the ratio of oxyhemoglobin (HbO ) to the total concentration of hemoglobin (i.e. Oxyhemoglobin + reduced hemoglobin) present in the blood. It is an important physiological parameter involved in respiration and circulation.
  • Page 14: Product Features

    INV-430J/PE uses a proprietary algorithm to to keep your finger still during measurement. It is also not collect data from pulsatile arterial blood only and ignores local advisable to use this instrument during sports activities noise from the tissues. The relative absorption of light by as movement may lead to inaccuracies.
  • Page 15: Limitations

    (around 60 mm Hg) of the Rate from the OLED Screen oxyhemoglobin dissociation curve. The INV-430J/PE pulse oximeter comes with anti-motion technology so that the pulse oximeter can function even if there is finger movement. However, for best results, try...
  • Page 16: Innovative Features Of The Inv-430J/Pe

    Innovative features of the INV-430J/PE The INV-430J/PE attempts to ameliorate some of the above problems by 1) Increasing the sensitivity of the sensor so that it can measure the user’s SpO and Pulse Rate (PR) at blood perfusion Index (PI) as low as 0.2%.
  • Page 17: Chapter 3 Product Structure Parameter Settings And Operation

    Chapter 3 Product Structure Parameter Settings and Operation Steps Schematic Structural Diagram 3.4.2 Installing the Sling Thread the thin end of the sling through the sling hole, OLED screen and thread the coarse end of the sling through the thin end of the sling, and tighten the sling.
  • Page 18: Schematic Diagram Of Display

    Schematic Diagram of Display Operation Steps The following figure shows the information display on the OLED 3.4.1 Installing the Batteries screen of the Oximeter in normal detection state: Install the two AAA dry batteries into the battery slot according to polarity indication, and mount the battery cover.
  • Page 19 To change the alarm range settings, HOLD the figure below). power-on/function key to enter Menu Interface 1.With the 3.3.2 Alarm Sound Setting "*" next to Alm Setup, HOLD the power-on key/function To turn the alarm on/off, PRESS the power-on key to enter in Menu Interface 2. "*" should be at key/function key to move "*"...
  • Page 20 The INV-430J/PE comes with two invaluable features, V2.01.E V2.01.E the plethysmograph and the perfusion index (PI), that Sounds Setup * Alm setup help the user determines if the readings are accurate Alm Hi and reliable. The plethysmograph indicates the amount...